New antimicrobial materials will be more and more in the focus for hygienic and clinical disease control. Antimicrobial materials have to be distinguished in leaching and nonleaching materials. For many applications of antimicrobial materials on implants the use of nonleaching materials is essential. Therefore, the antimicrobial efficiency of leaching and nonleaching polymers has been investigated quantitatively in vitro in direct comparison on a highly relevant implant of central venous catheters (CVCs) using a well‐established called Certika test. This test is especially designed to test antimicrobial properties of leachable and nonleachable materials. This contribution demonstrates that newly developed nonleaching antimicrobial CVCs are equivalent to conventional leaching CVC systems in their antimicrobial performance against gram‐positive and gram‐negative bacteria, as well as Candida species. The use of new nonleaching antimicrobial polymers as shown here for CVCs represents a different mode of action with the aim to prevent infections also with antibiotic‐resistant strains and reduced side effects. image
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Central Venous Catheters and Hemodialysis · Antibiotics Pharmacokinetics and Efficacy · Infection Control in Healthcare
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
QualityLabs BT GmbH Neumeyerstr. 46 a 90411 Nuremberg Germany
Medical Marketing GmbH Gleueler Straße 237 50935 Cologne Germany
Chair of Macromolecular Chemistry II University of Bayreuth Universitätsstrasse 30 95440 Bayreuth Germany
B. Braun Melsungen AG Carl‐Braun‐Straße 1 34212 Melsungen Germany
References (40)
Show source-provided references
1. 10.1016/j.biomaterials.2013.07.08910.1016/j.biomaterials.2013.07.089 ↗
2. 10.1016/j.actbio.2012.01.01110.1016/j.actbio.2012.01.011 ↗
3. 10.1097/01.CCM.0000201404.05523.3410.1097/01.CCM.0000201404.05523.34 ↗
4. 10.1186/cc885310.1186/cc8853 ↗
5. 10.1056/NEJMoa06111510.1056/NEJMoa061115 ↗
6. 10.1186/2110-5820-1-3410.1186/2110-5820-1-34 ↗
7. 10.1097/00075197-200105000-0000810.1097/00075197-200105000-00008 ↗
8. 10.1179/joc.2001.13.6.59510.1179/joc.2001.13.6.595 ↗
9. 10.1097/QCO.0b013e3282ffd6e010.1097/QCO.0b013e3282ffd6e0 ↗
10. 10.3310/hta1212010.3310/hta12120 ↗
11. 10.7326/0003-4819-132-5-200003070-0000910.7326/0003-4819-132-5-200003070-00009 ↗
12. 10.3201/eid0702.01020810.3201/eid0702.010208 ↗
13. 10.1086/50177610.1086/501776 ↗
14. 10.1016/S1473-3099(08)70280-910.1016/S1473-3099(08)70280-9 ↗
15. Shah P. S. · Cochrane Database Syst. Rev. · 2007 · 4 · CD005983
16. 10.1016/j.ajic.2007.02.01210.1016/j.ajic.2007.02.012 ↗
17. 10.1093/jac/dkl52210.1093/jac/dkl522 ↗
18. 10.1016/j.jhin.2010.04.02510.1016/j.jhin.2010.04.025 ↗
19. 10.1213/01.ANE.0000184200.40689.EB10.1213/01.ANE.0000184200.40689.EB ↗
20. 10.1007/s00134-003-2093-410.1007/s00134-003-2093-4 ↗
21. 10.1089/sur.2011.01110.1089/sur.2011.011 ↗
22. 10.1056/NEJM19990603340221310.1056/NEJM199906033402213 ↗
23. 10.1097/00000542-199711000-0003110.1097/00000542-199711000-00031 ↗
24. 10.1128/AAC.00350-0610.1128/AAC.00350-06 ↗
25. 10.1093/jac/47.5.58910.1093/jac/47.5.589 ↗
26. 10.1086/50183610.1086/501836 ↗
27. 10.1016/j.jtv.2010.06.00210.1016/j.jtv.2010.06.002 ↗
28. 10.1186/cc964910.1186/cc9649 ↗
29. 10.1016/j.eurpolymj.2015.01.03010.1016/j.eurpolymj.2015.01.030 ↗
30. Munoz‐Bonilla A. · Polym. Sci. · 2012 · 27 · 2
31. 10.3390/polym401004610.3390/polym4010046 ↗
32. Timofeeva L. · Appl. Microbiol. Biotechnol. · 2010 · 3 · 89
33. 10.1016/j.tibtech.2005.05.00410.1016/j.tibtech.2005.05.004 ↗
34. 10.1016/j.nantod.2012.04.00310.1016/j.nantod.2012.04.003 ↗
35. 10.1128/AAC.01622-0510.1128/AAC.01622-05 ↗
36. “J. I. S. Z 2801:2010 Antimicrobial Products‐Test for Antimicrobial Activity and Efficacy ”www.jsa.or.jp(accessed: 2011–12).
37. “ASTM E2180–07(2012) Standard Test Method for Determining the Activity of Incorporated Antimicrobial Agent(s) in Polymeric or Hydrophobic Materials ”www.astm.org(accessed: 2012–04).
38. 10.1038/7956810.1038/79568 ↗
39. 10.1504/IJNBM.2010.03611110.1504/IJNBM.2010.036111 ↗
40. 10.1002/9780470750186.ch1310.1002/9780470750186.ch13 ↗