Corrosion evaluation of steel bars in steam-cured concrete under chloride attack and alkali–silica reaction
Source abstract
Abstract
One of the challenges to reinforced concrete slabs in bridges is deterioration due to rebar corrosion by deicing salts. In order to simulate a concrete slab subjected to deicing salt penetration from the top surface of the bridge slab during winter, high-strength steam-cured concrete with double-layer reinforcements was exposed to 10% sodium chloride solution to investigate rebar corrosion. Five concrete mix proportions were prepared, including high early strength concrete and concrete containing fly ash and blast furnace slag as supplementary cementitious materials (SCMs). For both the high early strength and fly ash concretes, alkali active andesite in the pessimum proportion was mixed with coarse aggregates to investigate the effect of alkali–silica reaction (ASR) on rebar corrosion. It was found that the combined effects of chloride attack and ASR adversely affected the corrosion resistance of high early strength concrete. Fly ash concrete had excellent performance as to corrosion resistance and ASR mitigation. Results also showed that a widely used electrochemical technique known as the half-cell potential test can satisfactorily diagnose corrosion of double-layer reinforced concrete. Concrete specimens containing SCMs with no ASR threat showed no signs of steel bar corrosion and significantly low chloride diffusion coefficients after 3 years.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Concrete and Cement Materials Research · Smart Materials for Construction
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
PhD candidate, Division of Field Engineering for the Environment, Graduate School of Engineering, Hokkaido University, Sapporo, Japan
Professor, Division of Civil Engineering, Faculty of Engineering, Hokkaido University, Sapporo, Japan (corresponding author: )
References (35)
Show source-provided references
1. 10.1007/BF0248329210.1007/BF02483292 ↗
2. 10.1016/j.corsci.2011.01.02510.1016/j.corsci.2011.01.025 ↗
3. Bertolini L and Polder R (1997) Concrete Resistivity and Reinforcement Corrosion Rate as a Function of Temperature and Humidity of the Environment. Netherlands Organization for Applied Scientific Research, Delft, the Netherlands.
4. 10.1016/S1065-7355(97)00030-810.1016/S1065-7355(97)00030-8 ↗
5. 10.1111/jace.1209810.1111/jace.12098 ↗
6. 10.1016/0008-8846(78)90047-910.1016/0008-8846(78)90047-9 ↗
7. 10.1016/0008-8846(87)90040-810.1016/0008-8846(87)90040-8 ↗
8. 10.1016/S0008-8846(96)00180-910.1016/S0008-8846(96)00180-9 ↗
9. 10.1016/0008-8846(93)90139-Z10.1016/0008-8846(93)90139-Z ↗
10. 10.1016/0008-8846(94)90122-810.1016/0008-8846(94)90122-8 ↗
11. 10.1179/00070597079832445010.1179/000705970798324450 ↗
12. Habuchi T · Proceedings of Japan Concrete Institute · 2004 · 26 · 1017
13. Hansson CM · 1988 · 3
14. Hayashi K · Cement Science and Concrete Technology · 2009 · 157 · 334
15. 10.1617/s11527-015-0788-y10.1617/s11527-015-0788-y ↗
16. Helmuth R · 1993
17. 10.1016/S0008-8846(02)00753-610.1016/S0008-8846(02)00753-6 ↗
18. 10.1016/j.cemconres.2009.06.00410.1016/j.cemconres.2009.06.004 ↗
19. 10.1016/j.cemconres.2007.06.00810.1016/j.cemconres.2007.06.008 ↗
20. 10.1680/adcr.2000.12.2.5710.1680/adcr.2000.12.2.57 ↗
21. 10.1016/j.cemconres.2016.11.00210.1016/j.cemconres.2016.11.002 ↗
22. Kawabata Y · 2012
23. Metha PK · 2014
24. 10.1016/S0958-9465(01)00074-910.1016/S0958-9465(01)00074-9 ↗
25. 10.1016/S0008-8846(99)00271-910.1016/S0008-8846(99)00271-9 ↗
26. 10.1016/j.cemconres.2015.05.02410.1016/j.cemconres.2015.05.024 ↗
27. 10.1680/macr.1998.50.2.14710.1680/macr.1998.50.2.147 ↗
28. Spears RE · Concrete International · 1983 · 5 · 15
29. 10.1016/j.cemconres.2005.03.00210.1016/j.cemconres.2005.03.002 ↗
30. 10.3130/aijsx.407.0_110.3130/aijsx.407.0_1 ↗
31. Tuutti K · 1982
32. Vennesland O · Materials Performance · 1981 · 20 · 49
33. Wang N · 2020 · 4137
34. Yamada K · 2016
35. 10.1680/macr.14.0006910.1680/macr.14.00069 ↗