journal article·2017-11

Cracking in walls with combined base and end restraint

Marianna Micallef, Robert L. Vollum, Bassam A. Izzuddin

Magazine of Concrete Research· Volume 69· Issue 22
Publisher page

Abstract

Restraint of early-age thermal and long-term shrinkage strain can cause cracking in reinforced-concrete members. Eurocode 2 provides guidance on the design of crack control reinforcement in reinforced-concrete elements with base (edge) and end restraint, but not combined base and end restraint, which commonly occurs. The paper describes an experimental programme, which was conducted to investigate early-age and long-term shrinkage cracking in reinforced-concrete walls with combined base and end restraint. The main variables in the test programme were concrete cover and reinforcement ratio. Early-age cracking is simulated with non-linear finite-element analysis, which is shown to capture the observed behaviour adequately. Eurocode 2 gives reasonable estimates of long-term crack widths in the tested walls if edge restraint is assumed, but significantly overestimates crack widths if the worst case of end restraint is assumed.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Concrete Properties and Behavior · Fire effects on concrete materials · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Civil and Environmental Engineering, Imperial College London, London, UK

Department of Civil and Environmental Engineering, Imperial College London, London, UK (corresponding author: )

References (22)

Show source-provided references
1. Al Rawi RS · ACI Structural Journal · 1990 · 87 · 397
2. Altoubat SA · ACI Materials Journal · 2001 · 98 · 323
3. 10.1680/macr.1988.40.145.21610.1680/macr.1988.40.145.216 ↗
4. Bamforth PB · 2014
5. Carlson RW · ACI Structural Journal · 1988 · 85 · 395
6. CEB-FIP (Comité Euro-International du Béton-Fédération Internationale du Béton) · 1998
7. fib (Fédération International du Béton) · 2013
8. Forth JP · 2014
9. Gilbert RI · ACI Structural Journal · 1992 · 89 · 141
10. Izzuddin BA (1991) Nonlinear Dynamic Analysis of Framed Structures. PhD thesis, Department of Civil Engineering, Imperial College, University of London, London, UK.
11. Kheder GF · ACI Structural Journal · 1997 · 94 · 262
12. Kheder GF · ACI Materials Journal · 1994 · 91 · 150
13. Kovler K · Materials and Structures · 1999 · 32 · 38310.1007/BF02479631 ↗
14. 10.1016/j.engstruct.2005.12.00210.1016/j.engstruct.2005.12.002 ↗
15. Micallef M (2015) Crack Control in Base-Restrained Reinforced Concrete Walls. PhD thesis, Department of Civil and Environmental Enginneering, Imperial College London, London, UK.
16. 10.1016/j.engstruct.2017.04.03510.1016/j.engstruct.2017.04.035 ↗
17. Nejadi S · ACI Structural Journal · 2004 · 101 · 840
18. Stoffers H · Heron · 1978 · 23 · 1-A4.4
19. 10.1016/S0958-9465(03)00078-710.1016/S0958-9465(03)00078-7 ↗
20. Vollum RL · Magazine · 2002 · 54 · 273
21. 10.1680/macr.2007.0012510.1680/macr.2007.00125 ↗
22. Yang EI · ACI Structural Journal · 2000 · 97 · 751