journal article·1952-03

Tests on concrete beams reinforced with 12 gauge wires of an ultimate strength of 120 tons per sq.in.

K. Hajnal-Kónyi

Magazine of Concrete Research· Volume 3· Issue 9
Publisher page

Abstract

Summary: Two beams of 8 × 18 in. cross-section, 12 ft long, reinforced with twenty-eight 12 gauge wires of an ultimate strength of 120 tons per sq.in. were rested to failure on a span of 11 ft. The concrete cube strength was 3,990 and 5,400 lb per sq.in. respectively. In both cases failure occurred by fracture of the reinforcement although the wires were not prestressed. Strain measurements taken at various stages of loading show a linear distribution. The actual steel stress at failure was much higher than the stress obtained from the stress-strain diagram of the steel on the basis of the average strain measured at 97 per cent of the maximum load.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Engineering and Materials Analysis · Structural Load-Bearing Analysis · Fire effects on concrete materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.