journal article·2019-12-01Open access

Study of the Effect of Current Pulse Frequency on Ti-6Al-4V Alloy Coating Formation by Micro Arc Oxidation

Alexander Sobolev, Alexey Kossenko, Konstantin Borodianskiy

Materials· Volume 12· Issue 23

Abstract

The micro arc oxidation (MAO) process has been applied to produce ceramic oxide coating on Ti-6Al-4V alloy. The MAO process was carried out at the symmetric bipolar square pulse in electrolyte containing Na2CO3 and Na2SiO3. The effect of current frequency on the surface morphology, the chemical and the phase compositions as well as the corrosion resistance was examined. Morphology and cross-sectional investigation by electron microscopy evaluated more compacted and less porous coating produced by high current frequency (1000 Hz). This alloy also exhibited a high corrosion resistance in comparison with the untreated alloy. Additionally, the alloy subjected to MAO treatment by a current frequency of 1000 Hz showed a higher corrosion resistance in comparison with alloys obtained by lower current frequencies. This behavior was attributed to more compacted and less porous morphology of the coating.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Metal and Thin Film Mechanics · High-Temperature Coating Behaviors · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Chemical Engineering, Ariel University, Ariel 40700, Israel

References (27)

Show source-provided references
1. Simultaneously improving mechanical properties and corrosion resistance of pure Ti by continuous ECAP plus short-duration annealing10.1016/j.matchar.2018.01.050 ↗
2. Characterization of titanium alloy Ti-6Al-4V for chemical, marine and industrial applications10.1016/j.matchar.2003.10.006 ↗
3. Preparation and properties of plasma electrolytic oxidation coating on sandblasted pure titanium by a combination treatment10.1016/j.msec.2014.06.005 ↗
4. Review on titanium and titanium based alloys as biomaterials for orthopaedic applications10.1016/j.msec.2019.04.064 ↗
5. Sobolev, A., Wolicki, I., Kossenko, A., Zinigrad, M., and Borodianskiy, K. (2018). Coating formation on Ti-6Al-4V alloy by micro arc oxidation in molten salt. Materials, 11.10.3390/ma11091611 ↗
6. Plasma electrolysis for surface engineering10.1016/S0257-8972(99)00441-7 ↗
7. Characterization of oxide films produced by plasma electrolytic oxidation of a Ti–6Al–4V alloy10.1016/S0257-8972(00)00719-2 ↗
8. Effect of cathodic micro-discharges on oxide growth during plasma electrolytic oxidation (PEO)10.1016/j.surfcoat.2015.01.076 ↗
9. Microstructure, corrosion and wear performance of plasma electrolytic oxidation coatings formed on Ti–6Al–4V alloy in silicate-hexametaphosphate electrolyte10.1016/j.surfcoat.2012.12.003 ↗
10. The effect of surface roughness on PEO-treated Ti-6Al-4V alloy and corrosion resistance10.1016/j.surfcoat.2017.05.044 ↗
11. Bioactive coating on titanium alloy with high osseointegration and antibacterial Ag nanoparticles10.1021/acsami.9b13849 ↗
12. Mierzejewska, Ż., Hudák, R., and Sidun, J. (2019). Mechanical Properties and Microstructure of DMLS Ti6Al4V Alloy Dedicated to Biomedical Applications. Materials, 12.10.3390/ma12010176 ↗
13. Tailoring of antibacterial and osteogenic properties of Ti6Al4V by plasma electrolytic oxidation10.1016/j.apsusc.2018.04.267 ↗
14. Commercially pure titanium (cp-Ti) versus titanium alloy (Ti6Al4V) materials as bone anchored implants—Is one truly better than the other?10.1016/j.msec.2016.01.032 ↗
15. Bioactive coatings on Ti6Al4V alloy formed by plasma electrolytic oxidation10.1016/j.surfcoat.2015.07.053 ↗
16. Evaluation of micromechanical behaviour of plasma electrolytic oxidation (PEO) coatings on Ti–6Al–4V10.1016/j.surfcoat.2010.04.006 ↗
17. Effects of reagent purity on plasma electrolytic oxidation of titanium in an aluminate—Phosphate electrolyte
18. Characterization of the plasma electrolytic oxidation of titanium in sodium metasilicate10.1016/j.apsusc.2012.10.183 ↗
19. Preparation of ceramic coating on Ti substrate by Plasma electrolytic oxidation in different electrolytes and evaluation of its corrosion resistance: Part 210.1016/j.apsusc.2011.10.064 ↗
20. The plasma electrolytic oxidation (PEO) coatings to enhance in-vitro corrosion resistance of Ti–29Nb–13Ta–4.6Zr alloys: The combined effect of duty cycle and the deposition frequency10.1016/j.surfcoat.2019.06.025 ↗
21. Study of duty cycle influence on the band gap energy of TiO2/P coatings obtained by PEO process10.1016/j.surfcoat.2019.06.021 ↗
22. Anodic processes in plasma electrolytic oxidation of aluminium in alkaline solutions10.1016/j.electacta.2003.11.027 ↗
23. Spectroscopic study of electrolytic plasma and discharging behaviour during the plasma electrolytic oxidation (PEO) process10.1088/0022-3727/43/10/105203 ↗
24. Investigation of the plasma electrolytic oxidation mechanism of titanium10.1016/j.apsusc.2019.05.250 ↗
25. Characteristics of in-situ synthesized hydroxyapatite on TiO2 ceramic via plasma electrolytic oxidation10.1016/j.ceramint.2018.10.206 ↗
26. Review of the anatase to rutile phase transformation10.1007/s10853-010-5113-0 ↗
27. Raman spectra of titanium dioxide10.1016/0022-4596(82)90006-8 ↗