Stress Distribution within the Peri-Implant Bone for Different Implant Materials Obtained by Digital Image Correlation
Source abstract
Abstract
Stress distribution and its magnitude during loading heavily influence the osseointegration of dental implants. Currently, no high-resolution, three-dimensional method of directly measuring these biomechanical processes in the peri-implant bone is available. The aim of this study was to measure the influence of different implant materials on stress distribution in the peri-implant bone. Using the three-dimensional ARAMIS camera system, surface strain in the peri-implant bone area was compared under simulated masticatory forces of 300 N in axial and non-axial directions for titanium implants and zirconia implants. The investigated titanium implants led to a more homogeneous stress distribution than the investigated zirconia implants. Non-axial forces led to greater surface strain on the peri-implant bone than axial forces. Thus, the implant material, implant system, and direction of force could have a significant influence on biomechanical processes and osseointegration within the peri-implant bone.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Dental Clinic 2-Dental Prosthodontics, University Hospital Erlangen, Glueckstrasse 11, 91054 Erlangen, Germany
Clinic for Oro- and Maxillofacial Surgery, University hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053 Regensburg, Germany
References (44)
Show source-provided references
1. Intra-osseous anchorage of dental prostheses. I. Experimental studies
2. Analysis of load transfer and stress distribution by an implant-supported fixed partial denture10.1016/S0022-3913(96)90486-2 ↗
3. Wolff’s Law and bone’s structural adaptations to mechanical usage: An overview for clinicians
4. Lack of integration of smooth titanium surfaces: A working hypothesis based on strains generated in the surrounding bone10.1034/j.1600-0501.1999.100601.x ↗
5. A 2003 update of bone physiology and Wolff’s Law for clinicians
6. The influence of the location of load transfer on strains around implants supporting four unit cement-retained fixed prostheses: In vitro evaluation of axial versus off-set loading10.1046/j.1365-2842.2002.00867.x ↗
7. Effect of implant size and shape on implant success rates: A literature review10.1016/j.prosdent.2005.04.018 ↗
8. Machined and plastic copings in three-element prostheses with different types of implant-abutment joints: A strain gauge comparative analysis10.1590/S1678-77572010000300005 ↗
9. Microstrain around dental implants supporting fixed partial prostheses under axial and non-axial loading conditions, in vitro strain gauge analysis10.1097/SCS.0b013e31829ac83d ↗
10. Peri-implant biomechanical responses to standard, short-wide, and mini implants supporting single crowns under axial and off-axial loading (an in vitro study)10.1563/AAID-JOI-D-11-00102 ↗
11. Biomechanical analyses of one-piece dental implants composed of titanium, zirconia, PEEK, CFR-PEEK, or GFR-PEEK: Stresses, strains, and bone remodeling prediction by the finite element method10.1002/jbm.b.34890 ↗
12. A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia10.3390/ma8030932 ↗
13. Khaohoen, A., Sornsuwan, T., Chaijareenont, P., Poovarodom, P., Rungsiyakull, C., and Rungsiyakull, P. (2023). Biomaterials and Clinical Application of Dental Implants in Relation to Bone Density-A Narrative Review. J. Clin. Med., 12.10.3390/jcm12216924 ↗
14. Bone-metal interface in osseointegration10.1016/0022-3913(87)90344-1 ↗
15. Titanium oral implants: Surface characteristics, interface biology and clinical outcome10.1098/rsif.2010.0118.focus ↗
16. Titanium and titanium alloys in dentistry: Current trends, recent developments, and future prospects10.1016/j.heliyon.2022.e11300 ↗
17. Implants and components: Entering the new millennium
18. In vitro color changes of soft tissues caused by restorative materials
19. Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown10.1016/j.prosdent.2004.12.019 ↗
20. Comparison of clinical performance of zirconia implants and titanium implants in animal models: A systematic review10.11607/jomi.2817 ↗
21. Osseointegration and clinical success of zirconia dental implants: A systematic review
22. In Vitro Biofilm Formation on Titanium and Zirconia Implant Surfaces10.1902/jop.2016.160245 ↗
23. In vitro color changes of soft tissues caused by dyed fluorescent zirconia and nondyed, nonfluorescent zirconia in thin mucosa10.11607/prd.1303 ↗
24. One-piece zirconia oral implants: One-year results from a prospective cohort study. 1. Single tooth replacement10.1111/j.1600-051X.2012.01876.x ↗
25. Evaluation of a one-piece ceramic implant used for single-tooth replacement and three-unit fixed partial dentures: A prospective cohort clinical trial10.1111/clr.12670 ↗
26. Stability of prototype two-piece zirconia and titanium implants after artificial aging: An in vitro pilot study10.1111/j.1708-8208.2008.00116.x ↗
27. Influence of finish line in the distribution of stress trough an all ceramic implant-supported crown.: A 3D Finite Element Analysis
28. Three-Dimensional Finite Element Analysis of Stress Distribution in Zirconia and Titanium Dental Implants10.1563/aaid-joi-D-16-00109 ↗
29. Brenner, S.C. (2008). The Mathematical Theory of Finite Element Methods, Springer. [3rd ed.].10.1007/978-0-387-75934-0 ↗
30. Matta, R.E., Riegger, K., Trägler, H., Adler, W., Eitner, S., Wichmann, M., and Motel, C. (2021). Establishment of a New Biomechanical Measurement Method for Surface Deformation of Bone by Force Application via Dental Implants—A Pilot Study. Appl. Sci., 11.10.3390/app11167568 ↗
31. Bakalarz, M.M., and Tworzewski, P.P. (2023). Application of Digital Image Correlation to Evaluate Strain, Stiffness and Ductility of Full-Scale LVL Beams Strengthened by CFRP. Materials, 16.10.3390/ma16031309 ↗
32. Correlations between photogrammetric measurements of tooth mobility and the Periotest method10.3109/00016357.2011.575080 ↗
33. Bond strength of restorative materials to hydroxyapatite inserts and dimensional changes of insert-containing restorations during polymerization10.1016/j.dental.2014.11.017 ↗
34. Local deformation fields and marginal integrity of sculptable bulk-fill, low-shrinkage and conventional composites10.1016/j.dental.2016.09.011 ↗
35. Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants10.4103/njms.njms_354_21 ↗
36. In vitro testing for hip head-neck taper tribocorrosion: A review of experimental methods10.1177/09544119221074582 ↗
37. Masoomi, F., and Mahboub, F. (2024). Stress distribution pattern in all-on-four maxillary restorations supported by porous tantalum and solid titanium implants using three-dimensional finite element analysis. Eur. J. Transl. Myol., 34.10.4081/ejtm.2024.12170 ↗
38. Influence of Ceramic Materials on Biomechanical Behavior of Implant Supported Fixed Prosthesis with Hybrid Abutment
39. Measurement of tooth and implant mobility under physiological loading conditions10.1016/j.aanat.2011.09.007 ↗
40. Observations on the effect of movement on bone ingrowth into porous-surfaced implants10.1097/00003086-198607000-00023 ↗
41. Biomechanical factors affecting the bone-dental implant interface10.1016/0267-6605(92)90049-Y ↗
42. The influence of abutment angulation on micromotion level for immediately loaded dental implants: A 3-D finite element analysis
43. Factors associated with early and late failure of dental implants10.1111/j.2041-1626.2012.00162.x ↗
44. The effect of loading on peri-implant bone: A critical review of the literature10.1111/joor.12195 ↗