In Vivo Safety of New Coating for Biodegradable Magnesium Implants
Source abstract
Abstract
Biodegradable Magnesium (Mg) implants are promising alternatives to permanent metallic prosthesis. To improve the biocompatibility and with the aim of degradation control, we provided Plasma Electrolytic Oxidation (PEO) of pure Mg implant in silicate-based solution with NaOH (S1 250 V) and Ca(OH)2 (S2 300 V). Despite the well-structured surface, S1 250 V implants induced enormous innate immunity reaction with the prevalence of neutrophils (MPO+) and M1-macrophages (CD68+), causing secondary alteration and massive necrosis in the peri-implant area in a week. This reaction was also accompanied by systemic changes in visceral organs affecting animals’ survival after seven days of the experiment. In contrast, S2 300 V implantation was associated with focal lymphohistiocytic infiltration and granulation tissue formation, defining a more favorable outcome. This reaction was associated with the prevalence of M2-macrophages (CD163+) and high density of αSMA+ myofibroblasts, implying a resolution of inflammation and effective tissue repair at the site of the implantation. At 30 days, no remnants of S2 300 V implants were found, suggesting complete resorption with minor histological changes in peri-implant tissues. In conclusion, Ca(OH)2-contained silicate-based solution allows generating biocompatible coating reducing toxicity and immunogenicity with appropriate degradation properties that make it a promising candidate for medical applications.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Bone Tissue Engineering Materials · Aluminum Alloys Composites Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Biomedical Research Centre, Sumy State University, R-Korsakova Street, 40007 Sumy, Ukraine
Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland
Medical Laboratory CSD, Vasylkivska Street, 45, 02000 Kyiv, Ukraine
Institute of Atomic Physics and Spectroscopy, University of Latvia, Jelgavas iela 3, LV-1004 Riga, Latvia
Institute of Anatomy, Medical Faculty, University of Duisburg-Essen, 45147 Essen, Germany
Funding
National Research Foundation of Ukraine
References (27)
Show source-provided references
1. Biodegradable magnesium alloys as temporary orthopaedic implants: A review10.1007/s10534-019-00170-y ↗
2. Magnesium-based biomaterials as emerging agents for bone repair and regeneration: From mechanism to application10.1016/j.jma.2021.03.004 ↗
3. Santos, V., Uddin, M., and Hall, C. (2023). Mechanical Surface Treatments for Controlling Surface Integrity and Corrosion Resistance of Mg Alloy Implants: A Review. J. Funct. Biomater., 14.10.3390/jfb14050242 ↗
4. Design of magnesium alloys with controllable degradation for biomedical implants: From bulk to surface10.1016/j.actbio.2016.09.005 ↗
5. Ciosek, Ż., Kot, K., Kosik-Bogacka, D., Łanocha-Arendarczyk, N., and Rotter, I. (2021). The Effects of Calcium, Magnesium, Phosphorus, Fluoride, and Lead on Bone Tissue. Biomolecules, 11.10.3390/biom11040506 ↗
6. A novel magnesium ion-incorporating dual-crosslinked hydrogel to improve bone scaffold-mediated osteogenesis and angiogenesis10.1016/j.msec.2021.111868 ↗
7. Controlling the degradation rate of AZ91 magnesium alloy via sol–gel derived nanostructured hydroxyapatite coating10.1016/j.msec.2013.05.014 ↗
8. Improving the corrosion behavior of magnesium alloys with a focus on AZ91 Mg alloy intended for biomedical application by microstructure modification and coating10.1177/09544119221105705 ↗
9. Composite Nanocoatings of Biomedical Magnesium Alloy Implants: Advantages, Mechanisms, and Design Strategies10.1002/advs.202300658 ↗
10. A review of the physiological impact of rare earth elements and their uses in biomedical Mg alloys10.1016/j.actbio.2021.06.004 ↗
11. Guo, X., Hu, Y., Yuan, K., and Qiao, Y. (2022). Review of the Effect of Surface Coating Modification on Magnesium Alloy Biocompatibility. Materials, 15.10.3390/ma15093291 ↗
12. Surface modification of magnesium alloys developed for bioabsorbable orthopedic implants: A general review10.1002/jbm.b.32707 ↗
13. Oleshko, O., Kornienko, V., Kyrylenko, S., Simka, W., Husak, Y., Oleshko, T., Dryhval, B., Dudko, J., and Pogorielov, M. (2020, January 9–13). Physical and Chemical Characterization of the Magnesium Surface Modified by Plasma Electrolytic Oxidation—Influence of Immersion in Simulated Body Fluid. Proceedings of the 2020 IEEE 10th International Conference Nanomaterials: Applications & Properties (NAP), Odessa, Ukraine.10.1109/NAP51477.2020.9309586 ↗
14. Husak, Y., Kornienko, V., Simka, W., Oleshko, O., Oleshko, T., Dryhval, B., Dudko, J., and Pogorielov, M. (2020, January 9–13). Structural and Biological Assessment of Mg Alloy Surface after Plasma Electrolytic Oxidation in Different Solutions. Proceedings of the 2020 IEEE 10th International Conference Nanomaterials: Applications & Properties (NAP), Odessa, Ukraine.10.1109/NAP51477.2020.9309693 ↗
15. Husak, Y., Grebnevs, V., Altundal, S., Kazek-Kesik, A., Yanovska, A., Maciej, A., Gudakov, O., Komiienko, V., Viter, R., and Pogorielov, M. (2022, January 11–16). Effect Of CaP-particles on Ceramic-like Coatings Formed on Magnesium via Anodisation. Proceedings of the 2022 IEEE 12th International Conference Nanomaterials: Applications & Properties (NAP), Krakow, Poland.10.1109/NAP55339.2022.9934636 ↗
16. Husak, Y., Michalska, J., Oleshko, O., Korniienko, V., Grundsteins, K., Dryhval, B., Altundal, S., Mishchenko, O., Viter, R., and Pogorielov, M. (2021). Bioactivity performance of pure mg after plasma electrolytic oxidation in silicate-based solutions. Molecules, 26.10.3390/molecules26072094 ↗
17. Fibronectin and vitronectin promote human fetal osteoblast cell attachment and proliferation on nanoporous titanium surfaces10.1166/jbn.2013.1601 ↗
18. Recent advance in surface modification for regulating cell adhesion and behaviors10.1515/ntrev-2020-0076 ↗
19. Degradability and biocompatibility of magnesium-MAO: The consistency and contradiction between in-vitro and in-vivo outcomes10.1016/j.arabjc.2018.07.010 ↗
20. Al-Azzam, N., and Alazzam, A. (2022). Micropatterning of cells via adjusting surface wettability using plasma treatment and graphene oxide deposition. PLoS ONE, 17.10.1371/journal.pone.0269914 ↗
21. Evaluation of passive oxide layer formation–biocompatibility relationship in NiTi shape memory alloys: Geometry and body location dependency10.1016/j.msec.2013.11.040 ↗
22. Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque10.1016/j.jmbbm.2007.12.002 ↗
23. Magnesium implant degradation provides immunomodulatory and proangiogenic effects and attenuates peri-implant fibrosis in soft tissues10.1016/j.bioactmat.2023.02.014 ↗
24. Haslhofer, D.J., Gotterbarm, T., and Klasan, A. (2023). High Complication Rate and High Percentage of Regressing Radiolucency in Magnesium Screw Fixation in 18 Consecutive Patients. J. Pers. Med., 13.10.3390/jpm13020357 ↗
25. Inflammatory response to magnesium-based biodegradable implant materials10.1016/j.actbio.2019.10.014 ↗
26. Biocompatibility of magnesium implants in primary human reaming debris-derived cells stem cells in vitro10.1007/s10195-015-0364-9 ↗
27. Pre-clinical testing of human size magnesium implants in miniature pigs: Implant degradation and bone fracture healing at multiple implantation sites10.1016/j.msec.2019.110389 ↗