Influence of Deposition Temperature on Microstructure and Properties of Tantalum Oxide Sputtered Coatings
Source abstract
Abstract
To increase the wear and corrosion resistance of (α + β) titanium-aluminium-vanadium (Ti6Al4V) alloy, ceramic tantalum oxide coatings were deposited by direct current (DC) magnetron sputtering at three different substrate temperatures—400, 450, and 500 °C. The crystallographic structure, surface morphology, chemical compositions, film adhesion, and hardness of the coatings were described using XRD, SEM, EDS, scratch tests, and microhardness measurements. The samples’ ability to withstand corrosion was assessed using electrochemical studies. Results revealed that thin films have an amorphous or crystalline structure dependent on temperature. The film’s thicknesses varied between 560 and 600 nm. With the increase in deposition temperature, the hardness of the film rose. All oxide coatings were tightly adherent to the titanium alloy substrate, and critical force increased from about 8.6 up to 20 N when the temperature rose from 400 to 500 °C. During the polarisation investigations, after 1 h of immersion, a drop in current density (jcorr) verified an improvement in the corrosion resistance of the amorphous and well-crystalline coatings. A two-layer model of the surface film accurately describes the coated systems’ electrochemical behaviour. However, according to the EIS analysis, the well-crystalline film deteriorates greatly, whereas the amorphous film prevents penetration during the 7-day immersion test in SBF. The wettability tests demonstrated the hydrophilic nature of the coatings, and after seven days, the mineralisation of calcium phosphate proves the coatings become bioactive in simulated bodily fluid (SBF). Thus, we produced films of tantalum oxide, which, with the proper deposition parameters, may prove to be appropriate surfaces for titanium-based implant bio-applications.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Material Science and Technology, University of Ruse “Angel Kanchev”, 8 Studentska Str., 7017 Ruse, Bulgaria
Funding
European Union
References (69)
Show source-provided references
1. Biomaterial properties of titanium in dentistry10.1016/j.job.2015.08.001 ↗
2. Ti based biomaterials, the ultimate choice for orthopaedic implants—A review10.1016/j.pmatsci.2008.06.004 ↗
3. Titanium oxide films produced on commercially pure titanium by anodic oxidation with different voltages10.1016/j.matchar.2006.03.020 ↗
4. On the biocompatibility between TiO2 nanotubes layer and human osteoblasts10.1002/jbm.a.34188 ↗
5. Impact of diabetes mellitus and glycemic control on the osseointegration of dental implants: A systematic literature review10.1902/jop.2009.090283 ↗
6. Wear debris characterization and corresponding biological response: Artificial hip and knee joints10.3390/ma7020980 ↗
7. The biological response to titanium and titanium-aluminium-vanadium alloy particles10.1016/0142-9612(86)90085-2 ↗
8. Short term exposure to titanium, aluminum and vanadium (Ti 6Al 4V) alloy powder drastically affects behavior and antioxidant metabolites in vital organs of male albino mice10.1016/j.toxrep.2018.06.006 ↗
9. Improving corrosion resistance of Ti–6Al–4V alloy through plasma-assisted PVD deposited nitride coatings10.1016/j.corsci.2014.07.047 ↗
10. Synthesis of tantalum thin films on titanium by plasma immersion ion implantation and deposition10.1016/j.surfcoat.2012.04.044 ↗
11. Mechanical biocompatibilities of titanium alloys for biomedical applications10.1016/j.jmbbm.2007.07.001 ↗
12. Evaluation of the mechanical compatibility of additively manufactured porous Ti–25Ta alloy for load-bearing implant applications10.1016/j.jmbbm.2019.05.019 ↗
13. Metals for implantation in the human body10.1111/j.1749-6632.1968.tb20273.x ↗
14. Growth and characterization of tantalum multilayer thin films on CoCrMo alloy for orthopaedic implant applications10.1016/j.tsf.2017.11.017 ↗
15. Development of tantalum oxide (Ta-O) thin film coating on biomedical Ti-6Al-4V alloy to enhance mechanical properties and biocompatibility10.1016/j.ceramint.2015.08.133 ↗
16. Ceramic tantalum oxide thin film coating to enhance the corrosion and wear characteristics of Ti6Al4V alloy10.1016/j.jallcom.2016.03.188 ↗
17. Bioactivity response of Ta1-xOx coatings deposited by reactive DC magnetron sputtering10.1016/j.msec.2015.08.017 ↗
18. Fabrication of tantalum oxide layers onto titanium substrates for improved corrosion resistance and cytocompatibility10.1016/j.surfcoat.2015.04.024 ↗
19. The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution10.1016/S0142-9612(03)00252-7 ↗
20. Tailoring the synthesis of tantalum-based thin films for biomedical application: Characterization and biological response10.1016/j.msec.2019.03.072 ↗
21. Ta-Coated Titanium Surface with Superior Bacteriostasis And Osseointegration10.2147/IJN.S218640 ↗
22. Antibacterial properties and cytocompatibility of tantalum oxide coatings10.1016/j.surfcoat.2014.03.061 ↗
23. Corrosion resistance and biocompatibility of titanium surface coated with amorphous tantalum pentoxide10.1016/j.tsf.2012.06.088 ↗
24. A study on the electrodeposition of tantalum on NiTi alloy in an ionic liquid and corrosion behaviour of the coated alloy10.1016/j.elecom.2005.06.007 ↗
25. Direct laser processing of a tantalum coating on titanium for bone replacement structures10.1016/j.actbio.2009.11.021 ↗
26. Anbalagan, A.K., Cummings, R., Zhou, C., Mun, J., Stanic, V., Jordan-Sweet, J., Yao, J., Kisslinger, K., Weiland, C., and Nykypanchuk, D. (2025). Revealing the Origin and Nature of the Buried Metal-Substrate Interface Layer in Ta/Sapphire Superconducting Films. Adv. Sci., 2413058.10.1002/advs.202413058 ↗
27. Effect of deposition pressure on the microstructure, mechanical, and corrosion properties of tantalum nitride thin films deposited by reactive pulsed laser deposition10.1016/j.vacuum.2025.114228 ↗
28. Plasma-Enhanced Atomic Layer Deposition of Amorphous Tantalum Thin Films for Copper Interconnects Using an Organometallic Precursor10.1002/admt.202301541 ↗
29. Superior corrosion resistance of high-temperature Ir–Ni–Ta–(B) amorphous alloy in sulfuric acid solution10.1016/j.corsci.2022.110227 ↗
30. Fabrication and anticorrosion behavior of a bi-phase TaNbHfZr/CoCrNi multilayer coating through magnetron sputtering10.1016/j.corsci.2021.110020 ↗
31. A survey on crystallization kinetic behavior of direct current magnetron sputter deposited NiTi thin films10.1016/j.physb.2021.413086 ↗
32. Infrared optical properties of amorphous and nanocrystalline Ta2O5 thin films10.1063/1.4819325 ↗
33. Li, J., Liu, W., Wei, Y., and Yan, Y. (2022). Effect of Oxygen Content on the Properties of Sputtered TaOx Electrolyte Film in All-Solid-State Electrochromic Devices. Coatings, 12.10.3390/coatings12121831 ↗
34. Effect of growth and annealing temperatures on crystallization of tantalum pentoxide thin film prepared by RF magnetron sputtering method10.1016/j.jallcom.2008.07.126 ↗
35. Calcium phosphate-based coatings on titanium and its alloys10.1002/jbm.b.30932 ↗
36. Repassivating tantalum/tantalum oxide surface modification on stainless steel implants10.1016/S0257-8972(01)01096-9 ↗
37. Modulation of electrical properties of sputtered Ta2O5 films by variation of RF power and substrate temperature10.1088/1402-4896/ad196b ↗
38. Atomic layer deposition of ZnO transparent conducting oxides10.1016/S0169-4332(96)01022-7 ↗
39. Influence of magnetron sputtering conditions on the chemical bonding, structural, morphological and optical behavior of Ta1−xOx coatings10.1016/j.surfcoat.2017.11.001 ↗
40. Ohring, M. (2002). Materials Science of Thin Films: Deposition and Structure, Academic Press. [2nd ed.].10.1016/B978-012524975-1/50012-4 ↗
41. Martin, N., Cote, J.-M., Gavoille, J., and Potin, V. (2023). Tantalum Oxide Thin Films Sputter-Deposited by Oxygen Gas Pulsing. Coatings, 13.10.3390/coatings13111932 ↗
42. Reduction of mechanical losses in ion-beam sputtered tantalum oxide thin films via partial crystallization10.1088/1361-6382/ad3c8a ↗
43. Physical Vapour Deposition and Bioactivity of Crystalline Titanium Dioxide Thin Films
44. Fracture toughness, hardness, and Young’s modulus of tantalum nanocrystalline films10.1063/1.3496000 ↗
45. Reactive-sputter-deposited β-Ta2O5 and TaON nanoceramic coatings on Ti–6Al–4V alloy against wear and corrosion damage10.1016/j.surfcoat.2016.04.004 ↗
46. A comparative study of TiO2, Ta2O5 and Nb2O5 coated Ti6Al4V titanium alloy for biomedical applications10.1016/j.ceramint.2024.09.390 ↗
47. A simple model for the formation of compressive stress in thin films by ion bombardment10.1016/0040-6090(93)90201-Y ↗
48. Wang, L., Aversa, R., Houa, Z., Tian, J., Liang, S., Ge, S., Chen, Y., Perrotta, V., Apicella, A., and Apicella, D. (2021). Bioresorption control and biological response of magnesium alloy AZ31 coated with poly-β-hydroxybutyrate. Appl. Sci., 11.10.20944/preprints202105.0185.v1 ↗
49. A review on the wettability of dental implant surfaces II: Biological and clinical aspects10.1016/j.actbio.2014.03.032 ↗
50. Investigation of tantalum oxynitride for hard and anti-corrosive coating application in diluted hydrochloric acid solutions10.1016/j.mtcomm.2020.101113 ↗
51. Observations of localised instability of passive titanium in chloride solution10.1016/0013-4686(95)00126-Y ↗
52. Response of boride coating on the Ti-6Al-4V alloy to corrosion and fretting corrosion behavior in Ringer’s solution for bio-implant application10.1016/j.apsusc.2017.09.223 ↗
53. Bio-corrosion impacts on mechanical integrity of ZM21 Mg for orthopaedic implant application processed by equal channel angular pressing10.1007/s10856-021-06535-5 ↗
54. Corrosion resistance for biomaterial applications of TiO2 films deposited on titanium and stainless steel by ion-beam-assisted sputtering10.1002/(SICI)1097-4636(19970605)35:3<309::AID-JBM5>3.0.CO;2-L ↗
55. Instantaneous impedance monitoring of synergistic effect between cavitation erosion and corrosion processes10.1016/j.electacta.2016.01.216 ↗
56. Nonlinear Least Squares Fit Procedure for Analysis of Immittance Data of Electrochemical Systems10.1016/0167-2738(86)90031-7 ↗
57. SVET, SKP and EIS study of the corrosion behaviour of high strength Al and Al-Li alloys used in aircraft fabrication10.1016/j.corsci.2014.03.001 ↗
58. Corrosion behaviour of nanocomposite TiSiN coatings on steel substrates10.1016/j.corsci.2011.07.011 ↗
59. Degradable behavior and bioactivity of micro-arc oxidized AZ91D Mg alloy with calcium phosphate/chitosan composite coating in m-SBF10.1016/j.colsurfb.2013.05.040 ↗
60. Explore all metrics High-velocity suspension flame sprayed (HVSFS)hydroxyapatite coatings for biomedical applications10.1007/s11666-011-9724-z ↗
61. In vitro biocompatibility and degradation assessment of tantalum oxide coated Mg alloy as biodegradable implants10.1016/j.jallcom.2022.164272 ↗
62. Fabrication of hydroxyapatite/tantalum composites by pressureless sintering in different atmosphere10.1021/acsomega.1c01205 ↗
63. Characterization of tantalum and tantalum nitride films on Ti6Al4V substrate prepared by filtered cathodic vacuum arc deposition for biomedical applications10.1016/j.surfcoat.2018.05.007 ↗
64. Effects of bovine serum albumin on the corrosion behaviour of AISI 316L, Co–28Cr–6Mo, and Ti–6Al–4V alloys in phosphate buffered saline solutions10.1016/j.corsci.2011.06.009 ↗
65. Effects of TiO2 on microstructural, mechanical properties and in-vitro bioactivity of plasma sprayed yttria stabilised zirconia coatings for dental application10.1016/j.ceramint.2017.12.008 ↗
66. Titanium bioactivity surfaces obtained by chemical/electrochemical treatments
67. In vitro biocompatibility of a nanocrystalline β-Ta2O5 coating for orthopaedic implants10.1016/j.ceramint.2017.12.040 ↗
68. Novel sol gel coating of Nb2O5 on magnesium alloy for biomedical applications10.1016/j.surfcoat.2014.01.050 ↗
69. Biological Performance of Tantalum10.1016/0267-6605(94)90113-9 ↗