article·2019-09-25Open access

Investigation of Step-Stress Accelerated Degradation Test Strategy for Ultraviolet Light Emitting Diodes

Banglong Liang, Zili Wang, Cheng Qian, Yi Ren, Bo Sun, Dezhen Yang, Jing Zhou, Jiajie Fan

Abstract

III-nitride-based ultraviolet light emitting diode (UV LED) has numerous attractive applications in air and water purification, UV photolithography, and in situ activation of drugs through optical stimulus, solid state lighting, polymer curing, and laser surgery. However, the unclear failure mechanisms and uncertainty reliability have limited its application. Therefore, a design of an appropriate reliability test plan for UV LEDs has become extremely urgent. Compared to traditional reliability tests recommended in LED lighting industry, the step-stress accelerated degradation test (SSADT) is more cost-effective and time-effective. This paper compares three SSADT testing plans with temperature and driving currents as stepwise increasing loads to determine an appropriate test strategy for UV LEDs. The study shows that: (1) the failure mechanisms among different SSADT tests seem to be very different, since the driving current determines the failure mechanisms of UV LEDs more sensitively, and (2) the stepped temperature accelerated degradation test with an appropriate current is recommended for UV LEDs.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: GaN-based semiconductor devices and materials · Integrated Circuits and Semiconductor Failure Analysis · Electronic Packaging and Soldering Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References