Developing an Analogue Residual Limb for Comparative DVC Analysis of Transtibial Prosthetic Socket Designs
Source abstract
Abstract
Personalised prosthetic sockets are fabricated by expert clinicians in a skill- and experience-based process, with research providing tools to support evidence-based practice. We propose that digital volume correlation (DVC) may offer a deeper understanding of load transfer from prosthetic sockets into the residual limb, and tissue injury risk. This study’s aim was to develop a transtibial amputated limb analogue for volumetric strain estimation using DVC, evaluating its ability to distinguish between socket designs. A soft tissue analogue material was developed, comprising silicone elastomer and sand particles as fiducial markers for image correlation. The material was cast to form an analogue residual limb informed by an MRI scan of a person with transtibial amputation, for whom two polymer check sockets were produced by an expert prosthetist. The model was micro-CT scanned according to (i) an unloaded noise study protocol and (ii) a case study comparison between the two socket designs, loaded to represent two-legged stance. The scans were reconstructed to give 108 µm voxels. The DVC noise study indicated a 64 vx subvolume and 50% overlap, giving better than 0.32% strain sensitivity, and ~3.5 mm spatial resolution of strain. Strain fields induced by the loaded sockets indicated tensile, compressive and shear strain magnitudes in the order of 10%, with a high signal:noise ratio enabling distinction between the two socket designs. DVC may not be applicable for socket design in the clinical setting, but does offer critical 3D strain information from which existing in vitro and in silico tools can be compared and validated to support the design and manufacture of prosthetic sockets, and enhance the biomechanical understanding of the load transfer between the limb and the prosthesis.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Prosthetics and Rehabilitation Robotics · Orthopaedic implants and arthroplasty · Robotic Mechanisms and Dynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Bioengineering Science Research Group, School of Engineering, University of Southampton, Southampton SO17 1BJ, UK
µ-VIS X-Ray Imaging Centre, University of Southampton, Southampton SO17 1BJ, UK
Skin Health Research Group, School of Health Sciences, University of Southampton, Southampton SO16 6YD, UK
Institute for Life Sciences, University of Southampton, Southampton SO17 1BJ, UK
Funding
Engineering and Physical Sciences Research Council · Royal Academy of Engineering
References (48)
Show source-provided references
1. World Health Organization (2005). Guidelines for Training Personnel in Developing Countries for Prosthetics and Orthotics Services, World Health Organisation.
2. The cost of diabetic foot ulcers and amputations to the National Health Service in England10.1111/dme.13973 ↗
3. Landmine Survivors Network (2006). Prosthetics and Orthotics Programme Guide: Implementing P&O Services in Low-Income Settings, Landmine Survivors Network.
4. The UCLA Total Surface Bearing Suction Below-Knee Prosthesis
5. The Patellar-Tendon-Bearing Prosthesis for below-knee amputees, a review of technique and criteria
6. Variants of the PTB (Patellar-Tendon-Bearing) below-knee prosthesis
7. NHS England Special Commissioning (2018). Prosthetics Patient Survey Report, NHS England Special Commissioning.
8. Determinants of Skin Problems of the Stump in Lower-Limb Amputees10.1016/j.apmr.2008.07.015 ↗
9. Use and satisfaction with prosthetic limb devices and related services10.1016/j.apmr.2003.06.002 ↗
10. Comparison of prosthetic costs and service between osseointegrated and conventional suspended transfemoral prostheses10.1177/0309364612454160 ↗
11. A pressure and shear sensor system for stress measurement at lower limb residuum/socket interface10.1016/j.medengphy.2016.04.007 ↗
12. Establishing a measurement array to assess tissue tolerance during loading representative of prosthetic use10.1016/j.medengphy.2020.01.011 ↗
13. Computer-aided design of a prosthetic socket for an above-knee amputee
14. Interface load analysis for computer-aided design of below-knee prosthetic sockets10.1007/BF02446180 ↗
15. Steer, J.W., Worsley, P.R., Browne, M., and Dickinson, A.S. (2019). Predictive prosthetic socket design: Part 1—Population-Based evaluation of transtibial prosthetic sockets by FEA-driven surrogate modelling. Biomech. Model. Mechanobiol.10.1007/s10237-019-01195-5 ↗
16. Finite element analysis of the amputated lower limb: A systematic review and recommendations10.1016/j.medengphy.2017.02.008 ↗
17. Patient-specific analyses of deep tissue loads post transtibial amputation in residual limbs of multiple prosthetic users10.1016/j.jbiomech.2009.08.019 ↗
18. Digital volume correlation: Three-Dimensional strain mapping using x-ray tomography10.1007/BF02323555 ↗
19. Three-Dimensional deformation mapping of Mode i interlaminar crack extension in particle-toughened interlayers10.1016/j.actamat.2015.09.059 ↗
20. Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: A literature review10.1016/j.jbiomech.2014.01.001 ↗
21. Extracting accurate strain measurements in bone mechanics: A critical review of current methods10.1016/j.jmbbm.2015.06.006 ↗
22. Deformable image registration and 3D strain mapping for the quantitative assessment of cortical bone microdamage10.1016/j.jmbbm.2011.12.009 ↗
23. About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: A 3D zero-strain study10.1016/j.jbiomech.2014.07.019 ↗
24. Three-dimensional local measurements of bone strain and displacement: Comparison of three digital volume correlation approaches10.1115/1.4030174 ↗
25. A review of techniques for visualising soft tissue microstructure deformation and quantifying strain Ex Vivo10.1111/jmi.12701 ↗
26. Novel Method to Track Soft Tissue Deformation by Micro-Computed Tomography: Application to the Mitral Valve10.1007/s10439-015-1499-9 ↗
27. Measuring three-dimensional strain distribution in tendon10.1111/jmi.12009 ↗
28. Elastic stiffness characterization using three-dimensional full-field deformation obtained with optical coherence tomography and digital volume correlation10.1117/1.JBO.18.12.121512 ↗
29. 3D static elastography at the micrometer scale using Full Field OCT10.1364/BOE.4.002138 ↗
30. Quantifying deformations and strains in human intervertebral discs using Digital Volume Correlation combined with MRI (DVC-MRI)10.1016/j.jbiomech.2020.109604 ↗
31. In Vivo Strain Analysis of Dilated Ascending Thoracic Aorta by ECG-Gated CT Angiographic Imaging10.1007/s10439-017-1915-4 ↗
32. Tozzi, G., Fernandez, M.P., Davis, S., Karali, A., Kao, A.P., and Blunn, G. (2020). Full-Field Strain Uncertainties and Residuals at the Cartilage-Bone Interface in Unstained Tissues Using Propagation-Based Phase-Contrast XCT and Digital Volume Correlation. Materials, 13.10.3390/ma13112579 ↗
33. Noninvasive measurement of the stiffness of tissue in the above-knee amputation limb
34. Biomechanical assessment of below-knee residual limb tissue
35. ASTM D 575-91 (2001). Standard Test Methods for Rubber Properties in Compression, ASTM International.
36. Cagle, J.C., Reinhall, P.G., Hafner, B.J., and Sanders, J.E. (2017). Development of Standardized Material Testing Protocols for Prosthetic Liners. J. Biomech. Eng., 139.10.1115/1.4035917 ↗
37. Ampscan: A lightweight Python package for shape analysis of prosthetics and orthotics10.21105/joss.02060 ↗
38. Finite Element Analysis of Donning Procedure of a Prosthetic Transfemoral Socket10.1007/s10439-011-0389-z ↗
39. Strain-time cell-death threshold for skeletal muscle in a tissue-engineered model system for deep tissue injury10.1016/j.jbiomech.2008.03.039 ↗
40. There is an individual tolerance to mechanical loading in compression induced deep tissue injury10.1016/j.clinbiomech.2019.02.015 ↗
41. Development of a residuum/socket interface simulator for lower limb prosthetics10.1177/0954411917690764 ↗
42. Clinical utility of pressure feedback to socket design and fabrication10.1177/0309364619868364 ↗
43. Ramasamy, E., Avci, O., Dorow, B., Chong, S.Y., Gizzi, L., Steidle, G., Schick, F., and Röhrle, O. (2018). An efficient modelling-simulation-analysis workflow to investigate stump-socket interaction using patient-specific, three-dimensional, continuum-mechanical, finite element residual limb models. Front. Bioeng. Biotechnol., 6.10.3389/fbioe.2018.00126 ↗
44. Al-Fakih, E.A., Abu Osman, N.A., and Mahmad Adikan, F.R. (2016). Techniques for interface stress measurements within prosthetic sockets of transtibial amputees: A review of the past 50 years of research. Sensors, 16.10.3390/s16071119 ↗
45. Understanding Displacements of the Gel Liner for Below Knee Prosthetic Users10.1115/1.4040125 ↗
46. BS EN ISO 10328:2006 (2016). Prosthetics—Structural Testing of Lower-Limb Prostheses—Requirements and Test Methods, British Standards Institution.
47. MultiDIC: An open-source toolbox for multi-view 3D digital image correlation10.1109/ACCESS.2018.2843725 ↗
48. The dataset supporting the conclusions of this article is available in the University of Southampton repository, https://doi.org/10.5258/SOTON/D1528.