Free-Forging of Pure Titanium with High Reduction of Thickness by Plasma-Carburized SKD11 Dies
Source abstract
Abstract
A tool steel type SKD11 punch was plasma carburized at 673 K for 14.4 ks at 70 Pa to make carbon supersaturation. This carburized SKD11 punch was employed for upsetting the pure titanium wire with the diameter of 1.00 mm up to the reduction of thickness by 70% in a single shot. Its contact interface to titanium work was analyzed to describe the anti-galling behavior in this forging. Little trace of titanium proved that the galling process was suppressed by the in situ solid lubrication. The isolated free carbon agglomerates are wrought as a solid lubricant to sustain the galling-free forging process. This anti-galling upsetting reduced the residual strains in the forged wires. A long titanium wire with a length of 45 mm was incrementally upset to yield the titanium ribbon with a thickness of 0.3 mm, the width of 2.3 mm, and the length of 50 mm. The grain size of original pure titanium was much reduced to 2 μm on average. A micro-pillared microtexture was imprinted onto this forged titanium ribbon.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Metal and Thin Film Mechanics · Metal Alloys Wear and Properties · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Surface Engineering Design Laboratory, Shibaura Institute of Technology, Tokyo 144-0045, Japan
Komatsu-Seiki Kosakusho, Co., Ltd., Suwa 392-0012, Japan
Department of Mechanical Engineering, Faculty of Engineering, University of Toyama, Toyama 930-8555, Japan
References (27)
Show source-provided references
1. Kihara, T. (2019, January 9). Visualization of deforming process of titanium and titanium alloy using high speed camera. Proceedings of the JSTP-2019, Kyoto, Japan.
2. Tribology of dry deep-drawing of various metal sheets with use of ceramic tools10.1016/S0257-8972(03)00930-7 ↗
3. Galling phenomena in metal forming
4. SiC-coated SiC die for galling-free forging of pure titanium10.2320/matertrans.MT-ML2019006 ↗
5. Aizawa, T., Yoshino, T., Ito, K.-I., and Fukuda, T. (2020). Thick β-SiC CVD-coated SiC die system for dry forging of metals. J. Cryst., 10.10.3390/cryst10060539 ↗
6. Aizawa, T., Yoshino, T., Fukuda, T., and Shiratori, T. (2020). Dry cold forging of pure titanium wire to thin plate with use of β-SiC coating dies. J. Mater., 13.10.3390/ma13173780 ↗
7. Aizawa, T. (2021, January 5–10). In situ solid lubrication in cold dry forging of titanium by isolated free carbon from carbon- supersaturated dies. Proceedings of the 7th World Tribology Congress, Lyon, France. (In press).
8. Anti-galling cold dry forging of pure titanium by plasma carburized AISI420J2 dies
9. Plasma-carburizing—A surface heat treatment process for the new century10.1016/S0257-8972(01)01136-7 ↗
10. Kinetics of low temperature plasma carburizing of austenitic stainless steels10.1016/j.jmatprotec.2004.10.005 ↗
11. Low temperature plasma nitriding and carburizing for austenitic stainless steel
12. Aizawa, T., Yoshino, T., Shiratori, T., and Fukuda, T. (2021, January 10). Galling-free cold and warm forging of titanium wires to flat plates by SiC-coated SiC dies. Proceedings of the 24th International Conference on Material Forming, ESAFORM 2021, Liege, Belgium. (In press).10.25518/esaform21.1920 ↗
13. Microstructural evolution in commercial purity aluminum during high-pressure torsion10.1016/j.msea.2005.08.044 ↗
14. Shape, size and crystallographic orientation of the ferrite grains formed at grain boundaries of deformed austenite in a low carbon steel10.2355/tetsutohagane1955.86.12_807 ↗
15. Aizawa, T., Shiratori, T., and Komatsu, T. (2020). Micro-/nano-structuring in stainless steels by metal forming and materials processing. Electron Crystallography, IntechOpen. Chapter 5.10.5772/intechopen.91281 ↗
16. Use of endoscopic titanium stapler in recta anastomotic structure10.1007/s10350-004-6163-7 ↗
17. Froes, F., and Qian, M. (2018). Titanium in Medical and Dental Applications, Woodhead Publishing. [1st ed.].
18. Material and biofilm load of K wires in toe surgery: Titanium versus stainless steel10.1007/s11999-013-2919-5 ↗
19. Shiratori, T., Aizawa, T., Saito, Y., and Wasa, K. (2019). Plasma printing of an AISI316 micro-meshing punch array for micro-embossing onto copper plates. J. Metals, 9.10.3390/met9040396 ↗
20. Austenite phase transformation of SKD11 by surface heat treatment with a focused electron beam10.1016/j.surfcoat.2017.03.042 ↗
21. Application of response surface methodology to establish friction model of upset forging10.1177/1687814018766744 ↗
22. Molybdenum disulfide coating on AISI316 stainless steel by thermos-diffusion method10.1515/amm-2017-0265 ↗
23. Improvement of adhesion properties of glass prepared using SiC-deposited graphite old via low-temperature chemical vapor deposition10.1007/s43207-019-00010-2 ↗
24. Tribology in metal forming at elevated temperatures10.1007/s40544-015-0077-3 ↗
25. Development of a continuous rolling process for titanium wires
26. Cytocompatible and anti-bacterial adhesion nanotextured titanium oxide layer on titanium surfaces for dental and orthopedic implants10.3389/fbioe.2019.00103 ↗
27. Aizawa, T., Yoshino, T., and Inohara, T. (2020). Micro-/nano-texturing of aluminum by precise coining for functional surface decoration. J. Metals, 10.10.3390/met10081044 ↗