journal article·2020-11-11Open access

Selected Physicochemical Properties of Diamond Like Carbon (DLC) Coating on Ti-13Nb-13Zr Alloy Used for Blood Contacting Implants

Magdalena Antonowicz, Roksana Kurpanik, Witold Walke, Marcin Basiaga, Jozef Sondor, Zbigniew Paszenda

Materials· Volume 13· Issue 22

Abstract

Despite high interest in the issues of hemocompatibility of titanium implants, particularly those made of the Ti-13Nb-13Zr alloy, the applied methods of surface modification still do not always guarantee the physicochemical properties required for their safe operation. The factors that reduce the efficiency of the application of titanium alloys in the treatment of conditions of the cardiovascular system include blood coagulation and fibrous proliferation within the vessel’s internal walls. They result from their surfaces’ physicochemical properties not being fully adapted to the specifics of the circulatory system. Until now, the generation and development mechanics of these adverse processes are not fully known. Thus, the fundamental problem in this work is to determine the correlation between the physicochemical properties of the diamond like carbon (DLC) coating (shaped by the technological conditions of the process) applied onto the Ti-13Nb-13Zr alloy designed for contact with blood and its hemocompatibility. In the paper, microscopic metallographic, surface roughness, wettability, free surface energy, hardness, coating adhesion to the substrate, impendence, and potentiodynamic studies in artificial plasma were carried out. The surface layer with the DLC coating ensures the required surface roughness and hydrophobic character and sufficient pitting corrosion resistance in artificial plasma. On the other hand, the proposed CrN interlayer results in better adhesion of the coating to the Ti-13Nb-13Zr alloy. This type of coating is an alternative to the modification of titanium alloy surfaces using various elements to improve the blood environment’s hemocompatibility.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Diamond and Carbon-based Materials Research · Metal and Thin Film Mechanics · Tribology and Wear Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, 41-800 Zabrze, Poland

Department of Biomaterials and Composites, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, 30-059 Kraków, Poland

LISS a.s, Dopravni 2603, 756 61 Rožnov pod Radhoštěm, Czech Republic

Funding

Politechnika Śląska

References (39)

Show source-provided references
1. In vitro hemocompatibility testing of medical devices10.1016/j.thromres.2020.07.027 ↗
2. Siedlecki, A. (2018). Hemocompatibility of Biomaterials for Clinical Applications—Blood-Biomaterials Interactions, Woodhead Publishing.
3. Dee, K.C., Puelo, D.A., and Bizios, R. (2003). Tissue- Biomaterial Interactions, John Wiley & Sons.10.1002/0471270598 ↗
4. Hemocompatibility of plasma nitride 316L stainless steel: Effect of processing temperature10.1016/j.apsusc.2019.144704 ↗
5. The influence of surface topography of ceramics abutments on the attachment and proliferation of human oral fibroblasts10.1016/j.biomaterials.2004.02.037 ↗
6. Cell interactions with superhydrophilic and superhydrophobic surfaces10.1080/01694243.2012.697776 ↗
7. Surface modification of titanium, titanium alloys and related materials for biomedical applications10.1016/j.mser.2004.11.001 ↗
8. The effect of EO and steam sterilization on the mechanical and electrochemical properties of titanium grade 410.17222/mit.2014.241 ↗
9. Effects of topography and composition of titanium surface oxides on osteoblast responses10.1016/j.biomaterials.2003.11.011 ↗
10. Chiang, H.-J., Chou, H.-H., Ou, K.-L., Sugiatno, E., Ruslin, M., Waris, R.A., Huang, C.-F., Liu, C.-M., and Peng, P.-W. (2018). Evaluation of surface characteristics and hemocompatibility on the oxygen plasma-modified biomedical titanium. Metals, 8.10.3390/met8070513 ↗
11. The microbial infection of biomaterials: A challenge for clinicians and researchers. A short review
12. Antibacterial nanostructured composite films for biomedical applications: Microstructural characteristics, biocompatibility, and antibacterial mechanisms10.1080/08927014.2013.769967 ↗
13. Biofilm on dental implants: A review of the literature
14. Proteins, platelets, and blood coagulation at biomaterial interfaces10.1016/j.colsurfb.2014.09.040 ↗
15. Hybrid micro/nanostructural surface offering improved stress distribution and enhanced osseointegration properties of the biomedical titanium implant10.1016/j.jmbbm.2017.11.042 ↗
16. Narayan, R. (2013). Blood compatibility of diamond-like carbon (DLC) coatings. Diamond-Based Materials for Biomedical Applications, Woodhead Publishing.10.1533/9780857093516 ↗
17. Roy, M. (2017). Protective hard coatings for tribological applications. Materials Under Extreme Conditions, Elsevier.10.1016/B978-0-12-801300-7.00008-5 ↗
18. Diamond coated artificial cardiovascular devices10.1016/j.surfcoat.2016.06.030 ↗
19. Surface properties and blood compatibility of commercially available diamond-like carbon coatings for cardiovascular devices
20. Influence of the carbon content on the corrosion and tribocorrosion performance of Ti-DLC coatings for biomedical alloys10.1016/j.triboint.2015.03.007 ↗
21. Wear and corrosion properties of diamond like carbon (DLC) coating on stainless steel, CoCrMo and Ti6Al4V substrates10.1016/j.surfcoat.2015.03.031 ↗
22. Tribocorrosion studies of metallic biomaterials: The effect of plasma nitriding and DLC surface modifications10.1016/j.jmbbm.2016.06.014 ↗
23. Retrospective life time estimation of failed and explanted diamond-like carbon coated hip joint balls10.1016/j.actbio.2012.04.016 ↗
24. Environmental effect on the load-dependent friction behavior of a diamond-like carbon film10.1016/j.triboint.2014.10.014 ↗
25. Tribo corrosion of diamond-like carbon deposited on Ti6Al4V10.1007/s11249-009-9408-8 ↗
26. Tribology of diamond-like carbon films: Recent progress and future prospects10.1088/0022-3727/39/18/R01 ↗
27. Tribological behaviors of a magnetron sputtered CrSiN coating under ambient air and wet environments10.1016/j.surfcoat.2017.05.093 ↗
28. Mechanical properties of atomic layer deposition (ALD) TiO2 layers on stainless steel substrates10.1002/mawe.201600527 ↗
29. A critical review of diamond like carbon coating for wear resistance applications10.1016/j.ijrmhm.2018.09.006 ↗
30. ASTM (2003). ASTM F-1713: Standard Specification for Wrought Titanium-13Niobium-13Zirconium Alloy for Surgical Implant Applications, ASTM.
31. ASTM (2010). ASTM E112: Standard Test Methods for Determining Average Grain Size, ASTM.
32. PKN (1997). PN–ISO 4288:1997: Wymagania Geometryczne Wyrobów. Struktura Geometryczna Powierzchni. Zasady i Procedury Oceny Struktury Geometrycznej Powierzchni, Metoda Profilowa, PKN.
33. PKN (2016). PN-EN ISO 20502:2016-05: Ceramika Wysokiej Jakości (Ceramika Zaawansowana, Techniczna Ceramika Zaawansowana) -Oznaczanie Adhezji Powłok Ceramicznych w Próbie Zarysowania, PKN.
34. PKN (2019). PN-EN ISO 10993-15: Biologiczna Ocena Wyrobów Medycznych—Część 15: Identyfikacja i Oznaczanie Ilościowe Produktów Degradacji Metali i Stopów, PKN.
35. Effects of surface wettability and contact time on protein adhesion to biomaterial surfaces10.1016/j.biomaterials.2007.03.032 ↗
36. Zastosowanie pomiarów kąta zwilżania i swobodnej energii powierzchniowej do charakterystyki powierzchni polimerów wykorzystywanych w medycynie
37. Metody badania biodegradacji materiałów polimerowych10.14314/polimery.2006.716 ↗
38. Gradient polymer surfaces for biomedical applications10.1016/j.progpolymsci.2007.06.001 ↗
39. Developments in mechanical heart valve prosthesis10.1007/BF02706448 ↗