In-Depth Characterization of Two Bioactive Coatings Obtained Using MAPLE on TiTaZrAg
Source abstract
Abstract
TiZrTaAg alloy is a remarkable material with exceptional properties, making it a unique choice among various industrial applications. In the present study, two types of bioactive coatings using MAPLE were obtained on a TiZrTaAg substrate. The base coating consisted in a mixture of chitosan and bioglass in which zinc oxide and graphene oxide were added. The samples were characterized in-depth through a varied choice of methods to provide a more complete picture of the two types of bioactive coating. The analysis included Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), ellipsometry, and micro-Raman. The Vickers hardness test was used to determine the hardness of the films and the penetration depth. Film adhesion forces were determined using atomic force microscopy (AFM). The corrosion rate was highlighted by polarization curves and by using electrochemical impedance spectroscopy (EIS). The performed tests revealed that the composite coatings improve the properties of the TiZrTaAg alloy, making them feasible for future use as scaffold materials or in implantology.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Magnesium Alloys: Properties and Applications · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References
Reference metadata was not supplied for this record.