Show source-provided references
2. The restoration of root filled teeth: A review of the clinical literature
10.1111/iej.13438 ↗6. The restoration of endodontically treated, single-rooted teeth with cast or direct posts and cores: A systematic review
10.1067/mpr.2002.123848 ↗7. Mishra, L., Khan, A.S., Velo, M.M.A.C., Panda, S., Zavattini, A., Rizzante, F.A.P., Arbildo Vega, H.I., Sauro, S., and Lukomska-Szymanska, M. (2020). Effects of Surface Treatments of Glass Fiber-Reinforced Post on Bond Strength to Root Dentine: A Systematic Review. Materials, 13.
10.3390/ma13081967 ↗11. Biomechanical considerations for the restoration of endodontically treated teeth: A systematic review of the literature--Part 1. Composition and micro- and macrostructure alterations
12. Aufbau endodontisch behandelter Zähne; Gemeinsame Stellungnahme der DGZMK, der DGZPW und der DGZ
13. Alles über moderne Stiftsysteme
15. Long-life physical property preservation and postendodontic rehabilitation with the Composipost
18. A literature review on the prosthetic treatment of structurally compromised teeth
19. Evidenz zu Stiftsystemen
31. Evaluation of load testing of postendodontic restorations in vitro: Linear compressive loading, gradual cycling loading and chewing simulation
10.1002/jbm.b.30321 ↗32. Schäfer, A. (2012). Einfluss der Kausimulation auf die Bruchfestigkeit und Randqualität Vollkeramischer Kronen auf Titan- und Glasfaserstiften. [Ph.D. Dissertation, Friedrich-Schiller-Universität].
33. Fracture strength and survival rate of endodontically treated maxillary incisors with approximal cavities after restoration with different post and core systems: An in-vitro study
10.1016/S0300-5712(01)00038-0 ↗34. Effect of incomplete crown ferrules on load capacity of endodontically treated maxillary incisors restored with fiber posts, composite build-ups, and all-ceramic crowns: An in vitro evaluation after chewing simulation
10.1080/00016350500331120 ↗35. Influence of different posts and cores on marginal adaptation, fracture resistance, and fracture mode of composite resin crowns on human mandibular premolars. An in vitro study
10.1016/j.jdent.2005.07.007 ↗36. In vitro comparison of the fracture resistance and failure mode of fiber, ceramic, and conventional post systems at various stages of restoration
10.1111/j.1532-849X.2001.00026.x ↗39. Evaluation of tooth analogs and type of restoration on the fracture resistance of post and core restored incisors
10.1002/jbm.b.31399 ↗40. Survival rate and fracture strength of endodontically treated maxillary incisors with moderate defects restored with different post-and-core systems: An in vitro study
41. Fracture resistance of endodontically treated teeth restored with composite posts
10.1067/mpr.2003.75 ↗43. Adaptation of adhesive posts and cores to dentin after fatigue testing
44. Bending resistance of prefabricated titanium posts following molten cast core attachment
55. Hohmann, A., and Hielscher, W. (2001). Lehrbuch der Zahntechnik, Band 1, Quintessenz Verlags-GmbH. [6th ed.].
56. Comparison of fracture resistance of bonded glass fiber posts at different lengths
57. Effect of Post Material and Length on Fracture Resistance of Endodontically Treated Premolars: An In-Vitro Study
60. Fracture Resistance of Endodontically Treated Anterior Teeth Restored with Different Post Systems: An In Vitro Study
61. Kraftübertragung von vorgefertigten Wurzelkanalstiften [The stress transmission of prefabricated root canal posts]
62. Influence of oversized dowel space preparation on the bond strengths of FRC posts
10.2341/08-53 ↗63. Reliability of fiber post bonding to root canal dentin after simulated clinical function in vitro
10.2341/11-066-L ↗65. Maximale Kaukraft als Berechnungsfaktor zahntechnischer Konstruktionen
66. Maximal bite force and its association with signs and symptoms of craniomandibular disorders in young Finnish non-patients
10.3109/00016359509005982 ↗70. Zur marginalen Passform von Kronen und Brücken [The marginal fit of crowns and bridges]
71. Histologisch-morphometrische Studie zur Bestimmung des zervikalen Randschlusses von Einzel- und Pfeilerkronen [Histologic-morphometric studies to determine the cervical marginal fit of single and pontic crowns]
72. Marxkors, R. (1988). Funktioneller Zahnersatz—Zweckmäßige Prothetische Versorgung, Carl Hanser Verlag. [3rd ed.].
73. Kronenrand und parodontale Reaktion—Ergebnisse einer histopathologischen Studie an 368 Sektionspräparaten
75. Prüfungsergebnisse zahnärztlicher Gußverfahren
76. Kronenrandschluß und -konturqualität in fünf Dentallaboratorien
77. Comparison of marginal fit of 3 different metal-ceramic systems: An in vitro study
78. Comparison of marginal and internal fit of press-on-metal and conventional ceramic systems for three- and four-unit implant-supported partial fixed dental prostheses: An in vitro study
10.1016/j.prosdent.2015.01.002 ↗79. Clinical evaluation of adhesively placed Cerec endo-crowns after 2 years--preliminary results
81. Influence of ferrule, post system, and length on biomechanical behavior of endodontically treated anterior teeth
10.1016/j.joen.2013.09.034 ↗82. Survival rate and fracture strength of incisors restored with different post and core systems and endodontically treated incisors without coronoradicular reinforcement
10.1097/00004770-200210000-00008 ↗83. Clinical long-term evaluation and failure characteristics of 1335 all-ceramic restorations
84. Verbundfestigkeit von 4 Glasfaserstiftsystemen bei Verwendung verschiedener Befestigungsmaterialien. Eine In-vitro-Studie