journal article·2023-05-26Open access

Influence of Root Post Materials and Aging on Fracture Strength and Marginal Gap Quality of Ceramic Crowns—An In Vitro Study

Christoph-Ludwig Hennig, André Stöcker, Ann Nitzsche, Justus Marquetand, Collin Jacobs, Florentine Jahn

Materials· Volume 16· Issue 11

Abstract

The design of and materials for prosthodontic abutments and posts have significant influences on the fracture resistance of restored teeth. This in vitro study compared the fracture strength and marginal quality of full-ceramic crowns as a function of the inserted root posts via simulation of a five-year period of use. Test specimens were prepared from 60 extracted maxillary incisors using titanium L9 (A), glass-fiber L9 (B), and glass-fiber L6 (C) root posts. The circular marginal gap behavior, linear loading capacity, and material fatigue after artificial aging were investigated. The marginal gap behavior and material fatigue were analyzed using electron microscopy. The linear loading capacity of the specimens was investigated using the Zwick Z005 universal testing machine. None of the tested root post materials showed statistically significant differences in marginal width values (p = 0.921), except in the case of marginal gap location. For Group A, there was a statistically significant difference from the labial to the distal (p = 0.012), mesial (p = 0.000), and palatinal (p = 0.005). Similarly, Group B showed a statistically significant difference from the labial to the distal (p = 0.003), mesial (p = 0.000), and palatinal (p = 0.003). Group C showed a statistically significant difference from the labial to the distal (p = 0.001) and mesial (p = 0.009). Linear load capacity reached mean values of 455.8–537.7 N, and micro-cracks occurred after artificial aging, predominantly in Groups B and C. Through the chosen experimental design, it was shown that the root post material and root post length had no influence on the fracture strength of the test teeth before or after artificial aging. However, the marginal gap location depends on the root post material and its length, which is wider mesially and distally and also tends to be greater palatinally than labially.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Erosion and Treatment · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Orthodontics, Center of Dental Medicine, University Hospital Jena, An der alten Post 4, 07743 Jena, Germany

Section of Geriodontics, Department of Conservative Dentistry and Periodontology, Center of Dental Medicine, University Hospital Jena, An der alten Post 4, 07743 Jena, Germany

Department of Epileptology, Hertie-Institute for Clinical Brain Research, University of Tübingen, 72076 Tübingen, Germany

Department of Neural Dynamics and Magnetoencephalography, Hertie-Institute for Clinical Brain Research, University of Tübingen, 72076 Tübingen, Germany

MEG-Center, University of Tübingen, 72076 Tübingen, Germany

Funding

Section of Geriodontics, Department of Conservative Dentistry and Periodontology, Center of Dental Medicine, University Hospital Jena

References (84)

Show source-provided references
1. The restoration of traumatized teeth10.1111/adj.12402 ↗
2. The restoration of root filled teeth: A review of the clinical literature10.1111/iej.13438 ↗
3. Retention of endodontic dowels: Effects of cement, dowel length, diameter, and design10.1016/S0022-3913(78)80156-5 ↗
4. Restoration of pulpless teeth: Application of traditional principles in present and future contexts10.1016/S0022-3913(96)90028-1 ↗
5. Resistance to fracture of endodontically treated teeth restored with different post systems10.1067/mpr.2002.123227 ↗
6. The restoration of endodontically treated, single-rooted teeth with cast or direct posts and cores: A systematic review10.1067/mpr.2002.123848 ↗
7. Mishra, L., Khan, A.S., Velo, M.M.A.C., Panda, S., Zavattini, A., Rizzante, F.A.P., Arbildo Vega, H.I., Sauro, S., and Lukomska-Szymanska, M. (2020). Effects of Surface Treatments of Glass Fiber-Reinforced Post on Bond Strength to Root Dentine: A Systematic Review. Materials, 13.10.3390/ma13081967 ↗
8. Restoration of endodontically treated teeth: A review of the literature10.1016/0022-3913(86)90068-5 ↗
9. The dentin-root complex: Anatomic and biologic considerations in restoring endodontically treated teeth10.1016/0022-3913(92)90073-J ↗
10. An analysis of durability data on post and core restorations10.1016/0300-5712(93)90108-3 ↗
11. Biomechanical considerations for the restoration of endodontically treated teeth: A systematic review of the literature--Part 1. Composition and micro- and macrostructure alterations
12. Aufbau endodontisch behandelter Zähne; Gemeinsame Stellungnahme der DGZMK, der DGZPW und der DGZ
13. Alles über moderne Stiftsysteme
14. Mechanical properties of endodontic posts10.1046/j.1365-2842.1997.00598.x ↗
15. Long-life physical property preservation and postendodontic rehabilitation with the Composipost
16. The mechanical properties of human dentin: A critical review and re-evaluation of the dental literature10.1177/154411130301400103 ↗
17. Mechanical properties of human dental enamel on the nanometre scale10.1016/S0003-9969(00)00089-3 ↗
18. A literature review on the prosthetic treatment of structurally compromised teeth
19. Evidenz zu Stiftsystemen
20. Clinically relevant approach to failure testing of all-ceramic restorations10.1016/S0022-3913(99)70103-4 ↗
21. Clinical relevance of tests on bond strength, microleakage and marginal adaptation10.1016/j.dental.2012.07.158 ↗
22. Need of a new classification for post and core failure10.4103/2155-8213.170640 ↗
23. Restorative difficulty evaluation system of endodontically treated teeth10.1111/jerd.12880 ↗
24. Influence of test parameters on in vitro fracture resistance of post-endodontic restorations: A structured review10.1111/j.1365-2842.2009.01940.x ↗
26. Determination of the minimum number of marginal gap measurements required for practical in-vitro testing10.1016/S0022-3913(00)70087-4 ↗
27. In vitro fracture resistance and marginal adaptation of metallic and tooth-coloured post systems10.1111/j.1365-2842.2004.01286.x ↗
28. Effect of post adaptation on fracture resistance of endodontically treated teeth10.1016/0022-3913(90)90037-D ↗
29. Thermal cycling procedures for laboratory testing of dental restorations10.1016/S0300-5712(98)00037-2 ↗
30. Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures10.1016/j.dental.2005.04.024 ↗
31. Evaluation of load testing of postendodontic restorations in vitro: Linear compressive loading, gradual cycling loading and chewing simulation10.1002/jbm.b.30321 ↗
32. Schäfer, A. (2012). Einfluss der Kausimulation auf die Bruchfestigkeit und Randqualität Vollkeramischer Kronen auf Titan- und Glasfaserstiften. [Ph.D. Dissertation, Friedrich-Schiller-Universität].
33. Fracture strength and survival rate of endodontically treated maxillary incisors with approximal cavities after restoration with different post and core systems: An in-vitro study10.1016/S0300-5712(01)00038-0 ↗
34. Effect of incomplete crown ferrules on load capacity of endodontically treated maxillary incisors restored with fiber posts, composite build-ups, and all-ceramic crowns: An in vitro evaluation after chewing simulation10.1080/00016350500331120 ↗
35. Influence of different posts and cores on marginal adaptation, fracture resistance, and fracture mode of composite resin crowns on human mandibular premolars. An in vitro study10.1016/j.jdent.2005.07.007 ↗
36. In vitro comparison of the fracture resistance and failure mode of fiber, ceramic, and conventional post systems at various stages of restoration10.1111/j.1532-849X.2001.00026.x ↗
37. Fatigue testing and microscopic evaluation of post and core restorations under artificial crowns10.1016/S0022-3913(99)70090-9 ↗
38. Static and fatigue fracture resistances of pulpless teeth restored with post-cores10.1016/j.dental.2008.01.009 ↗
39. Evaluation of tooth analogs and type of restoration on the fracture resistance of post and core restored incisors10.1002/jbm.b.31399 ↗
40. Survival rate and fracture strength of endodontically treated maxillary incisors with moderate defects restored with different post-and-core systems: An in vitro study
41. Fracture resistance of endodontically treated teeth restored with composite posts10.1067/mpr.2003.75 ↗
42. Effect of luting agents and reconstruction techniques on the fracture resistance of pre-fabricated post systems10.1111/j.1365-2842.2005.01438.x ↗
43. Adaptation of adhesive posts and cores to dentin after fatigue testing
44. Bending resistance of prefabricated titanium posts following molten cast core attachment
45. Effect of surface treatment on retention of glass-fiber endodontic posts10.1016/j.prosdent.2006.01.006 ↗
46. Resistance to fracture and structural characteristics of different fiber reinforced post systems10.1016/j.dental.2006.01.018 ↗
47. Post retentive ability of a new resin composite with low stress behaviour10.1016/j.jdent.2012.01.007 ↗
48. Reduction in tooth stiffness as a result of endodontic and restorative procedures10.1016/S0099-2399(89)80191-8 ↗
49. How biomechanics can affect the endodontic treated teeth and their restorative procedures?10.1590/1807-3107bor-2018.vol32.0076 ↗
50. Randomized controlled trial comparing glass fiber posts and cast metal posts10.1016/j.jdent.2020.103334 ↗
51. Effect of different restorative procedures on the fracture resistance of teeth submitted to internal bleaching10.1590/S1806-83242012000100013 ↗
52. Factors affecting retention of post systems: A literature review10.1016/S0022-3913(99)80002-X ↗
53. Comparison of fracture resistance between cast posts and fiber posts: A meta-analysis of literature10.1016/j.joen.2012.09.026 ↗
54. The effect of post material on the characteristic strength of fatigued endodontically treated teeth10.1016/j.prosdent.2014.03.014 ↗
55. Hohmann, A., and Hielscher, W. (2001). Lehrbuch der Zahntechnik, Band 1, Quintessenz Verlags-GmbH. [6th ed.].
56. Comparison of fracture resistance of bonded glass fiber posts at different lengths
57. Effect of Post Material and Length on Fracture Resistance of Endodontically Treated Premolars: An In-Vitro Study
58. Fracture resistance of endodontically treated teeth restored with glass fiber posts of different lengths10.1016/j.prosdent.2013.09.013 ↗
59. Cast or fiber posts a summary of evidence from vitro studies10.1038/sj.ebd.6400953 ↗
60. Fracture Resistance of Endodontically Treated Anterior Teeth Restored with Different Post Systems: An In Vitro Study
61. Kraftübertragung von vorgefertigten Wurzelkanalstiften [The stress transmission of prefabricated root canal posts]
62. Influence of oversized dowel space preparation on the bond strengths of FRC posts10.2341/08-53 ↗
63. Reliability of fiber post bonding to root canal dentin after simulated clinical function in vitro10.2341/11-066-L ↗
64. Masticatory function—A review of the literature. III. Masticatory performance and efficiency10.1111/j.1365-2842.1976.tb00929.x ↗
65. Maximale Kaukraft als Berechnungsfaktor zahntechnischer Konstruktionen
66. Maximal bite force and its association with signs and symptoms of craniomandibular disorders in young Finnish non-patients10.3109/00016359509005982 ↗
67. The effect of pressure on a maximum incisal bite force in man10.1016/S0003-9969(96)00106-9 ↗
68. Evaluation of molar and incisor bite force in indigenous compared with white population in Brazil10.1016/j.archoralbio.2007.10.003 ↗
69. Marginal adaptation of ceramic crowns: A systematic review10.1016/j.prosdent.2013.08.003 ↗
70. Zur marginalen Passform von Kronen und Brücken [The marginal fit of crowns and bridges]
71. Histologisch-morphometrische Studie zur Bestimmung des zervikalen Randschlusses von Einzel- und Pfeilerkronen [Histologic-morphometric studies to determine the cervical marginal fit of single and pontic crowns]
72. Marxkors, R. (1988). Funktioneller Zahnersatz—Zweckmäßige Prothetische Versorgung, Carl Hanser Verlag. [3rd ed.].
73. Kronenrand und parodontale Reaktion—Ergebnisse einer histopathologischen Studie an 368 Sektionspräparaten
74. Effects of tooth preparation burs and luting cement types on the marginal fit of extracoronal restorations10.1111/j.1532-849X.2008.00398.x ↗
75. Prüfungsergebnisse zahnärztlicher Gußverfahren
76. Kronenrandschluß und -konturqualität in fünf Dentallaboratorien
77. Comparison of marginal fit of 3 different metal-ceramic systems: An in vitro study
78. Comparison of marginal and internal fit of press-on-metal and conventional ceramic systems for three- and four-unit implant-supported partial fixed dental prostheses: An in vitro study10.1016/j.prosdent.2015.01.002 ↗
79. Clinical evaluation of adhesively placed Cerec endo-crowns after 2 years--preliminary results
80. Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations10.1111/j.1365-2842.2005.01446.x ↗
81. Influence of ferrule, post system, and length on biomechanical behavior of endodontically treated anterior teeth10.1016/j.joen.2013.09.034 ↗
82. Survival rate and fracture strength of incisors restored with different post and core systems and endodontically treated incisors without coronoradicular reinforcement10.1097/00004770-200210000-00008 ↗
83. Clinical long-term evaluation and failure characteristics of 1335 all-ceramic restorations
84. Verbundfestigkeit von 4 Glasfaserstiftsystemen bei Verwendung verschiedener Befestigungsmaterialien. Eine In-vitro-Studie