Application of Dual Focused Ultrasonic Phased Array Transducer in Two Orthogonal Cross-Sections for Inspection of Multi-Layered Composite Components of the Aircraft Fuselage
Source abstract
Abstract
Our previous studies have shown that the application of the proposed technique of a dual focused ultrasonic beam in two orthogonal cross-sections in passive (elevation) and active (azimuth) apertures of linear ultrasonic phased array transducer (ULPAT) enhances the 3D spatial resolution in the case of the inspection of conventional defects (flat bottom holes) or measurement of thickness of multi-layered metal composites. The objective of this work is to apply the proposed technique to enhance the spatial resolution of the ULPAT in the cases of detection and sizing demonstration of internal defects possessing spatially complex geometry, and during the inspection of defective multi-layered thin composite components (e.g., GLARE) of the aircraft fuselage. The specially prepared aluminium specimen possessing an internal defect of complicated geometry (crescent-shaped) was investigated. The simulation results and experiments demonstrate the resolution enhancement, higher amplitude of the reflections (e.g., 2.5 times or +8 dB) and spatial improvement in the defect detection even in the case of the non-perpendicular incidence of ultrasonic waves to the complex geometry surface of the internal defect. During the experiments, the multi-layered GFRP-metal based composite sample GLARE 3-3/2 was investigated in the case of the single-side access to the surface of the sample. The internal artificial delamination type defect of 25 mm was detected with a higher accuracy. Compared to the limitations of conventional ULPAT, the relative error (32%) (at the −6 dB level) of lateral defect dimensions estimation was completely reduced.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Non-Destructive Testing Techniques · Structural Health Monitoring Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Ultrasound Research Institute, Kaunas University of Technology, Baršausko str. 59, LT-51368 Kaunas, Lithuania
References (22)
Show source-provided references
1. A review of non-destructive testing methods of composite materials10.1016/j.prostr.2016.02.008 ↗
2. The detection of aeronautical defects in situ on composite structures using Non Destructive testing10.1016/j.compstruct.2010.10.017 ↗
3. Review of Non-Destructive Testing (NDT) techniques and their applicability to thick walled composites10.1016/j.procir.2015.07.043 ↗
4. Damage identification in aircraft composite structures: A case study using various non-destructive testing techniques10.1016/j.compstruct.2015.02.080 ↗
5. Acoustic detection of invisible damage in aircraft composite panels10.1016/j.apacoust.2007.12.012 ↗
6. Bisle, W., Meier, T., Mueller, S., and Rueckert, S. (2006, January 25–29). In-service inspection concept for GLARE®—An example for the use of new ut array inspection systems. Proceedings of the 9th ECNDT, Berlin, Germany.
7. Detection and evaluation of pre-preg gaps and overlaps in glare laminates10.1007/s10443-018-9679-z ↗
8. some inspection methods for quality control and in-service inspection of GLARE10.1023/A:1025537229801 ↗
9. Design of eddy current-based dielectric constant meter for defect detection in glass fiber reinforced plastics10.1016/j.ndteint.2015.04.005 ↗
10. Non-destructive damage detection in fibre metal laminates
11. Ultrasonic arrays for non-destructive evaluation: A review10.1016/j.ndteint.2006.03.006 ↗
12. Ultrasound transducer selection in clinical imaging practice10.7863/jum.2013.32.4.573 ↗
13. Jakubczak, P., Nardi, D., Bienias, J., and Sinke, J. (2019). Non-destructive testing investigation of gaps in thin glare laminates. Nondestruct. Test. Eval., 1–18.10.1080/10589759.2019.1684489 ↗
14. Coenen, R.A.M. (1998). Design of a Quality Assurance System for Structural Laminates. [Ph.D. Thesis, Delft University of Technology].
15. Development of the technique for independent dual focusing of contact type ultrasonic phased array transducer in two orthogonal planes10.1016/j.ndteint.2017.03.004 ↗
16. (2020, January 20). Available online: http://www.extende.com.
17. Jezzine, K., Segur, D., Ecault, R., and Dominguez, N. (2016, January 13–17). Simulation of ultrasonic inspections of composite structures in the CIVA software platform. Proceedings of the 19th World Conference on Non-Destructive Testing, Munich, Germany. Available online: http://ndt.net/?id=19438.
18. Assler, H., and Telgkamp, J. (2006, January 25–29). Design of aircraft structures under special consideration of NDT. Proceedings of the 9th ECNDT, Berlin, Germany.
19. Veres, I.A., and Smith, R.A. (2014, January 6–10). 3D characterisation of GLARE and other fibre-metal laminates. Proceedings of the 11th ECNDT, Praque, Czech Republic.
20. Numerical investigation of innovative nonlinear ultrasonic spectroscopy for detection and sizing interface defects in composites
21. Vlot, A., and Gunnink, J.W. (2001). Fibre Metal Laminates an Introduction, Kluwer Academic Publishers.10.1007/978-94-010-0995-9 ↗
22. Application of ultrasonic iterative deconvolution technique to the case of internal defect detection in multi-layered PCB components10.1784/insi.2010.52.1.27 ↗