Influence of Corrosion-Inhibiting Monolayers on the Bond Strength and Durability of Reinforced Concrete Structures Under Service Conditions
Source abstract
Abstract
Corrosion protection in reinforced concrete structures exposed to aggressive environments remains a critical challenge in civil and architectural engineering. One promising approach involves the application of corrosion-inhibiting monolayers on the reinforcement, such as those formed using 4-aminobenzoic acid. Two methods have previously been employed to generate these monolayers: one relying on the adhesion of an organic compound and the other utilising an externally modified approach via electrolysis. This study assesses the influence of this treatment on the steel–concrete bond strength and durability, both critical properties for the structural performance of reinforced concrete under service conditions. For this purpose, pull-out tests were performed on specimens subjected to load–unload cycles to analyse bond behaviour and monolayer integrity. The results indicate that these treatments do not adversely affect the bond strength between reinforcement and concrete. Furthermore, the rebars treated with the inhibitor exhibit less corrosion damage than the untreated rebars. This fact is particularly significant in the rebars treated using the natural adhesion method, with the steel section loss being 32–37% lower than in the untreated rebars. These findings support the feasibility of applying this treatment without compromising structural functionality.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Architectural Construction, Universitat Politècnica de València, Camino de Vera s/n, E-46022 Valencia, Spain
Institute of Molecular Recognition and Technological Development (IDM), Universitat Politècnica de València, Camino de Vera s/n, E-46022 Valencia, Spain
Funding
Spanish Government · Universitat Politècnica de València · Generalitat Valenciana
References (33)
Show source-provided references
1. Influence of corrosion inhibitors in reinforced concrete—A state of art of review10.1016/j.matpr.2022.09.118 ↗
2. Geng, Z., and Shi, J. (2024). Passivation behavior of steel in novel low-carbon binders with belitic calcium sulfoaluminate cement. Cem. Concr. Compos., 152.10.1016/j.cemconcomp.2024.105686 ↗
3. Wang, D., Yue, Y., and Qian, J. (2024). Effect of carbonation on the corrosion behavior of steel rebar embedded in magnesium phosphate cement. Compos. Part B Eng., 268.10.1016/j.compositesb.2023.111088 ↗
4. Effect of macrocell currents on rebar corrosion in reinforced concrete structures exposed to a marine environment
5. Lliso-Ferrando, J.R., Soto Camino, J., Gasch, I., and Valcuende Payá, M.O. (2023). Significance of macrocell currents in reinforced concrete columns partially immersed in seawater. Constr. Build. Mater., 389.10.1016/j.conbuildmat.2023.131739 ↗
6. Lliso-Ferrando, J.R., Gasch, I., Martínez-Ibernón, A., and Valcuende Payá, M.O. (2023). Macrocell Corrosion Currents in Simulated Con-crete Pore Solution and Reinforced Concrete. Int. J. Concr. Struct. Mater., 17.10.1186/s40069-022-00576-y ↗
7. Unraveling the impact of chloride and sulfate ions collection on atmospheric corrosion of steel10.5006/1030 ↗
8. A review of passivity breakdown on metal surfaces: Influence of chloride- and sul-fide-ion concentrations, temperature, and pH10.1007/s42247-021-00194-6 ↗
9. Calavera, J., Delibes, A., Izquierdo, J.M., and González, G. (1979). Influencia de la Oxidación y de las Manchas de Mortero Sobre la Adherencia de Armaduras de Hormigón, Intemac.
10. Green inhibitors for corrosion of metals in acidic media: A review
11. Amino acids and their derivatives as corrosion inhibitors for metals and alloys10.1016/j.arabjc.2017.07.013 ↗
12. Zhao, R., Xu, W., Yu, Q., and Niu, L. (2020). Synergistic effect of SAMs of S-containing amino acids and surfactant on corrosion inhibition of 316L stainless steel in 0.5 M NaCl solution. J. Mol. Liq., 318.10.1016/j.molliq.2020.114322 ↗
13. Pull-out test for studying bond strength in corrosion affected reinforced concrete structures—A review
14. Bond behaviour with reinforcement corrosion10.1016/j.conbuildmat.2015.05.067 ↗
15. Rilem (2018). Technical Recommendations for the Testing and Use of Construction Materials, CRC Press.
16. Corrosion propagation phase and bond strength degradation of rein-forced concrete structures: State of the art
17. Modified beam-end test setup to study the bond behavior of reinforcement in concrete after fire
18. The effect of functionalized polycarboxylate structures as corrosion inhibitors in a simulated concrete pore solution10.1016/j.apsusc.2018.02.012 ↗
19. Corrosion Inhibition Properties of Triazine Derivatives Containing Carboxylic Acid and Amine Groups in 1.0 M HCl Solution10.1021/ie303092j ↗
20. Okey, N.C., Obasi, N.L., Ejikeme, P.M., Ndinteh, D.T., Romasami, P., Sherif, E.M., Akpan, E.D., and Ebenso, E.E. (2020). Evaluation of some amino benzoic acid and 4-aminoantipyrine derived Schiff bases as corrosion inhibitors for steel in acidic medium: Systhesis, experimental and computational studies. J. Mol. Liq., 315.10.1016/j.molliq.2020.113773 ↗
21. Imjjad, A., Abbiche, K., Mellaoui, M.D., Jmiai, A., El Baraka, N., Taleb, A.A., Bazzi, I., El Issami, S., Hilali, M., and Said, R.B. (2022). Corrosion inhibition of mild steel by aminobenzoic acid isomers in hydrochloric acid solution: Efficiency and adsorption mechanisms. Appl. Surf. Sci., 576.10.1016/j.apsusc.2021.151780 ↗
22. Inhibition efficiency and adsorption mechanism of 4-aminobenzoic acid for copper corrosion in nitric acid medium: A combined experimental and theoretical investigation10.1007/s11224-021-01784-0 ↗
23. (2003). Testing Hardened Concrete—Part 3: Compressive Strength of Test Specimens (Standard No. UNE-EN 12390-3:2003).
24. (2006). Steel for the Reinforcement of Concrete–Weldable Reinforcing Steel–General (Standard No. EN 10080:2006).
25. Zhang, W., Liu, Z., Liu, Q., and Zhang, W. (2023). Investigation of bond behavior between waterborne epoxy-coated steel reinforcing bars (WECR) and concrete. J. Build. Eng., 76.10.1016/j.jobe.2023.107328 ↗
26. Experimental investigations on bond behaviour of reinforced concrete under transverse tensión and repeated loading10.1016/j.engstruct.2009.02.025 ↗
27. Bond to concrete of FRP rebars after cyclic loading10.1061/(ASCE)1090-0268(2000)4:3(137) ↗
28. Análisis de la corrosión de barras de acero en función de la variación del pH del medio10.21041/ra.v6i3.153 ↗
29. (2019). Building Code Requirements for Structural Concrete and Commentary (Standard No. ACI 318-19).
30. Fédération Internationale du Béton (fib) (2000). Bulletin No. 1: Bond of Reinforcement in Concrete, FIB.
31. (2011). Corrosión de Armaduras en Estructuras de Hormigón. Medida de la Velocidad de Corrosión de Armaduras en Probetas y Estructuras de Hormigón Armado. Método de la Resistencia de Polarización (Standard No. UNE 112072:2011).
32. Berke, N.S., Chaker, V., and Whiting, D.A. (1990). Corrosion Rates of Steel in Concrete (Standard No. ASTM STP 1065).10.1520/STP1065-EB ↗
33. RILEM Technical Committee TC-154 (2003). Electrochemical Techniques for Measuring Metallic Corrosion, RILEM Publications.