Bearing Thickness Is Not a Predictive Factor for Damage and Penetration in Oxford Unicompartmental Knee Arthroplasty—A Retrieval Analysis
Source abstract
Abstract
The medial Oxford unicompartmental knee arthroplasty (OUKA) shows good survivorship, as well as clinical results. Aseptic loosening, however, remains one of the main reasons for revision and polyethylene debris is known to cause aseptic loosening. The role of bearing thickness in total as well as unicondylar knee arthroplasty has been the subject of controversial discussions, especially the longevity of lower thickness bearings in total knee arthroplasty was questioned. The purpose of this study was to assess the influence of bearing thickness on time to revision, damage pattern, penetration, and volumetric material loss. A cohort of 47 consecutively retrieved medial OUKA bearings was analyzed with conventional direct light microscopy applying the Hood damage analysis, as well as measuring the penetration depth. In this retrieval cohort, a difference on survival time, damage, penetration, as well as volumetric material loss could not be seen. We conclude that low as well as high thickness bearings can safely be used in OUKA without any relevant differences in terms of wear and damage.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany
References (34)
Show source-provided references
1. Have the causes of revision for total and unicompartmental knee arthroplasties changed during the past two decades?10.1007/s11999-017-5316-7 ↗
2. The use of highly crosslinked polyethylene in total knee arthroplasty10.1302/0301-620X.99B8.BJJ-2017-0028.R1 ↗
3. Polyethylene Wear in Knee Arthroplasty10.1055/s-0035-1551833 ↗
4. (2020, October 14). Annual Report Australian Orthopaedic Association, Available online: https://aoanjrr.sahmri.com/de/annual-reports-2017.
5. Medial unicompartmental arthroplasty of the knee10.5435/JAAOS-D-17-00690 ↗
6. Long-term outcomes of over 8,000 medial Oxford Phase 3 Unicompartmental Knees—A systematic review10.1080/17453674.2017.1367577 ↗
7. The effect of bearing congruency, thickness and alignment on the stresses in unicompartmental knee replacements10.1016/j.clinbiomech.2008.06.001 ↗
8. Wear analysis of unicondylar mobile bearing and fixed bearing knee systems: A knee simulator study10.1016/j.actbio.2010.09.031 ↗
9. Unicondylar knee retrieval analysis10.1016/j.arth.2010.05.004 ↗
10. The clinical outcome of minimally invasive Phase 3 Oxford unicompartmental knee arthroplasty: A 15-year follow-up of 1000 UKAs10.1302/0301-620X.97B11.35634 ↗
11. Factors Affecting the postoperative limb alignment and clinical outcome after oxford unicompartmental knee arthroplasty10.1016/j.arth.2011.12.011 ↗
12. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement10.2106/00004623-198668070-00010 ↗
13. Stresses in polyethylene components of contemporary total knee replacements
14. Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses10.1302/0301-620X.74B1.1732274 ↗
15. McAuley, J.P., Engh, G.A., and Ammeen, D.J. (2001). Revision of failed unicompartmental knee arthroplasty. Clin. Orthop. Relat. Res., 279–282.10.1097/00003086-200111000-00036 ↗
16. Analysis of polyethylene thickness of tibial components in total knee replacement10.2106/00004623-200203000-00006 ↗
17. Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prostheses10.1002/jbm.820170510 ↗
18. Long-term in vivo wear of different bearing types used for the oxford unicompartmental knee replacement10.1302/2046-3758.811.BJR-2019-0163.R1 ↗
19. 3D patient imaging and retrieval analysis help understand the clinical importance of rotation in knee replacements10.1007/s00167-018-4891-9 ↗
20. Effect of e-beam sterilization on the in vivo performance of conventional UHMWPE tibial plates for total knee arthroplasty10.1016/j.actbio.2017.03.040 ↗
21. Wear of congruent meniscal bearings in unicompartmental knee arthroplasty: A retrieval study of 16 specimens10.1302/0301-620X.80B6.0800976 ↗
22. Analysis of wear in retrieved mobile and fixed bearing knee inserts10.1016/j.arth.2009.03.010 ↗
23. Polyethylene insert damage in unicondylar knee replacement: A comparison of in vivo function and in vitro simulation10.1243/09544119JEIM699 ↗
24. Wear-pattern analysis in retrieved tibial inserts of mobile-bearing and fixed-bearing total knee prostheses10.1302/0301-620X.92B4.22560 ↗
25. Mobile-bearing knees reduce rotational asymmetric wear10.1097/BLO.0b013e31806dba05 ↗
26. Polyethylene wear in Oxford unicompartmental knee replacement10.1302/0301-620X.92B3.22491 ↗
27. Polyethylene thickness in unicompartmental knee arthroplasty10.1016/j.knee.2010.04.012 ↗
28. Polyethylene thickness is a risk factor for wear necessitating insert exchange10.1007/s00264-011-1412-6 ↗
29. Relationship of surface damage appearance and volumetric wear in retrieved TKR polyethylene liners: Retrieved tkr polyethylene damage patterns and volumetric wear10.1002/jbm.b.33684 ↗
30. Retrieval analysis of contemporary antioxidant polyethylene: Multiple material and design changes may decrease implant performance10.1007/s00167-019-05387-5 ↗
31. Quantification of polyethylene degradation in mobile bearing knees: A retrieval analysis of the Anterior-Posterior-Glide (APG) and Rotating Platform (RP) Low Contact Stress (LCS) knee10.1080/17453670710013942 ↗
32. Similar polyethylene wear between cemented and cementless Oxford medial UKA: A 5-year follow-up randomized controlled trial on 79 patients using radiostereometry10.1080/17453674.2018.1543757 ↗
33. The robustness and accuracy of in vivo linear wear measurements for knee prostheses based on model-based RSA10.1016/j.jbiomech.2011.08.013 ↗
34. Validation of a model-based measurement of the minimum insert thickness of knee prostheses: A retrieval study10.1302/2046-3758.310.2000304 ↗