Potential differences between passive reinforcement segments in concrete components in dependency of binder type, aeration conditions and quality of the steel/concrete‐interface
Source abstract
Abstract
For exploring the chloride threshold level of steel in concrete, respectively the onset of active reinforcement corrosion in general, the environmental and electrochemical conditions in the passive state are decisive. For reinforced concrete structures in practice, possible characteristics of the inner polarization state and the resulting potential differences, mainly forced by moisture deviations in the structure, are not commonly known. In this paper the exploration of four slab like specimens and two column bases with “real” dimensions, which are cyclically exposed to chloride solution for simulating typical moisture conditions for outdoor structures, is described. Ordinary portland cement (OPC, CEM I) and blast‐furnace slag cement (BFSC, CEM III) are used. For various, decoupled segments of the reinforcing steel potential differences are determined and depolarization measurements are performed. The concrete compositions with different binder types show considerably diverging results. The maximum of the determined potential differences is 150 mV for OPC specimens and 650 mV for BFSC specimens. The extent of instant effects of changing exposure conditions also is completely different. Generally, exposure (wetting) causes a displacement of the potential to more negative values. Other impact parameters do not lead to a clear pattern of behavior or reaction.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Concrete and Cement Materials Research · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Building Materials Research, Conservation and Polymer Composites RWTH Aachen University Schinkelstr.3 52062 Aachen Germany
Funding
German Research Foundation
References (15)
Show source-provided references
1. Dauberschmidt C. · DBV‐Heft · 2010 · 19 · 65
2. 10.1016/S0013-4686(02)00351-110.1016/S0013-4686(02)00351-1 ↗
3. U. M.Angst B.Elsener presented at4th ICCRRR Leipzig Germany 5–7 September 2015 pp.177–184.
4. 10.5006/1.329032510.5006/1.3290325 ↗
5. 10.1016/j.corsci.2010.11.02510.1016/j.corsci.2010.11.025 ↗
6. Pillai R. G. · ACI Mater. J · 2005 · 103 · 103
7. Hausmann D. A. · Mater. Prot · 1967 · 6 · 19
8. 10.1016/S0008-8846(03)00087-510.1016/S0008-8846(03)00087-5 ↗
9. G. K.Glass B.Reddy presented atCorrosion of Steel in Reinforced Concrete Structures Luxembourgh Luxembourgh 18–19 February 2002 pp.227–232.
10. K.Pettersson presented at7th International Conference on DBMC Stockholm Sweden 19–23 May 1996 pp.334–341.
11. 10.1007/BF0248152610.1007/BF02481526 ↗
12. Schießl P. · 1988
13. Pourbaix M. · 1974
14. M.Beck Ph. D. Thesis RWTH Aachen University Germany2010.
15. H.Bornstedt Dipl. Thesis RWTH Aachen University Germany1988.