Study of Polypyrrole Coating on the Performance Improvement of Ag/AgCl Chloride Ion Sensor in Highly Alkaline Concrete Environments
Source abstract
Abstract
ABSTRACT Ag/AgCl possesses the merits of a stable reference potential and good chemical stability, making it widely used in concrete for monitoring chloride ions. However, in the concrete circumstance, the high hydroxide ion content would significantly deteriorate the sensitivity and stability of the Ag/AgCl electrode in detecting chloride ions. Herein, in this work, a highly sensitive and stable Ag/AgCl electrode is proposed by employing a protective coating layer based on polypyrrole (PPy). Using a facile coating process, a uniform PPy layer is coated on the surface of an Ag piece, effectively precluding hydroxide ions from reacting with AgCl. The modified Ag/AgCl electrode exhibits high sensitivity to chloride ions over a wide range (10−5–5 mol/L), fast response time (0.01 s), and distinguished long‐term stability (90 days). Moreover, the feasibility of the proposed Ag/AgCl electrode in monitoring chloride ions of concrete has been validated, suggesting its great practicability in concrete structures.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Smart Materials for Construction · Analytical Chemistry and Sensors · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Civil and Transportation Engineering Hohai University Nanjing China
School of Materials Science and Engineering Southesat Unversity Nanjing China
Hydraulic Concrete Institute, China Three Gorges Corporation Hohai University Beijing China
Funding
National Natural Science Foundation of China
References (33)
Show source-provided references
1. 10.1007/s10008-016-3238-z10.1007/s10008-016-3238-z ↗
2. 10.1016/j.compositesb.2019.02.05110.1016/j.compositesb.2019.02.051 ↗
3. 10.1016/0008-8846(84)90135-210.1016/0008-8846(84)90135-2 ↗
4. 10.1016/j.compositesb.2017.09.02910.1016/j.compositesb.2017.09.029 ↗
5. 10.1016/j.compositesb.2018.10.06910.1016/j.compositesb.2018.10.069 ↗
6. Determination of the Selectivity Coefficient of a Chloride Ion Selective Electrode in Alkaline Media Simulating the Cement Paste Pore Solution
7. 10.1016/j.conbuildmat.2018.04.13510.1016/j.conbuildmat.2018.04.135 ↗
8. 10.1016/j.compositesb.2018.11.10510.1016/j.compositesb.2018.11.105 ↗
9. 10.1016/S0950-0618(00)00063-510.1016/S0950-0618(00)00063-5 ↗
10. 10.1016/S0008-8846(03)00012-710.1016/S0008-8846(03)00012-7 ↗
11. 10.1617/s11527-006-9219-410.1617/s11527-006-9219-4 ↗
12. 10.1016/j.conbuildmat.2014.06.00910.1016/j.conbuildmat.2014.06.009 ↗
13. 10.1016/j.engstruct.2018.06.02610.1016/j.engstruct.2018.06.026 ↗
14. 10.1109/JSEN.2021.310058210.1109/JSEN.2021.3100582 ↗
15. Detection of Chlorides in Pore Water of Cement Based Materials by Potentiometric Sensors
16. 10.1016/j.jelechem.2009.11.01010.1016/j.jelechem.2009.11.010 ↗
17. 10.1016/S0950-0618(00)00062-310.1016/S0950-0618(00)00062-3 ↗
18. 10.1016/S0008-8846(96)85004-610.1016/S0008-8846(96)85004-6 ↗
19. 10.1002/maco.1978029080410.1002/maco.19780290804 ↗
20. 10.1016/S0013-4686(01)00678-810.1016/S0013-4686(01)00678-8 ↗
21. 10.1016/S0010-938X(01)00006-310.1016/S0010-938X(01)00006-3 ↗
22. 10.1002/elan.114007010310.1002/elan.1140070103 ↗
23. Role of Sensors in Corrosion Monitoring and Durability Assessment in Concrete Structures: The State of the Art
24. 10.1617/s11527-015-0673-810.1617/s11527-015-0673-8 ↗
25. 10.1016/S0925-4005(03)00456-810.1016/S0925-4005(03)00456-8 ↗
26. 10.1134/S102319350909010910.1134/S1023193509090109 ↗
27. 10.1007/s10008-007-0494-y10.1007/s10008-007-0494-y ↗
28. 10.1002/jbm.a.3104710.1002/jbm.a.31047 ↗
29. 10.1016/S0956-5663(97)00087-010.1016/S0956-5663(97)00087-0 ↗
30. 10.1016/j.conbuildmat.2007.12.01410.1016/j.conbuildmat.2007.12.014 ↗
31. 10.1149/1.243569610.1149/1.2435696 ↗
32. 10.1016/j.compositesb.2019.10743710.1016/j.compositesb.2019.107437 ↗
33. 10.1080/24705314.2016.115333810.1080/24705314.2016.1153338 ↗