Effect of cathodic protection on macrocell currents: A viable method to monitor and control the efficiency of CP?
Source abstract
Abstract
Abstract Corrosion protection of steel reinforcement in concrete structures by cathodic protection (CP) is a cost effective, reliable, and widely accepted method to stop and prevent the corrosion of the steel reinforcement. The efficiency of CP is usually monitored by the “24 h, 100 mV depolarization criterion,” a purely empirical criterion whose implementation is cost and labor intensive and that does not allow online control of CP. Within an extended research project on CP applied to concrete members of a highway bridge exposed to penetrating moisture, three sets of macrocells (MC), each composed of five MC sensors, were installed in conjunction with concrete resistance sensors and silver/silver chloride reference cells. Chloride profiles were determined from the cored or drilled powder originating from the installation of sensors and from drilling cores. Corrosion currents, steel potentials, and concrete resistance were monitored over a period of 1 year before, after installing the CP systems (which remained switched off for half a year for evaluating the effect of the conductive coating), and after start‐up of the CP systems. The CP systems applied consist of a moisture resistant conductive coating. As expected CP has a pronounced effect on local MC currents: Anodic MC currents were reduced or changed into cathodic currents, whereas cathodic currents were only weakly influenced. By adjusting the applied protection current all anodic MC currents may be changed into cathodic MC currents. Results indicate that the 100 mV depolarization criterion is a conservative criterion in atmospherically exposed concrete; it is not reliable in strongly wetted concrete. There was no consistent correlation between the CP induced changes in the local MC currents and 24 h depolarization values indicating that large potential shifts induced by CP do not necessarily imply overprotection. Results show that monitoring MC currents before, during, and after CP operation allows to demonstrate in a transparent way the effect of CP on the corrosion of the steel reinforcement. Online monitoring of MC currents is proposed as a viable and comprehensible method to monitor and control the efficiency of CP.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Smart Materials for Construction
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Nürnberger U. · 1995
2. Page C. L. · 1990
3. 10.4324/978020341460610.4324/9780203414606 ↗
4. Schwarz W. · 1999
5. Yoon S. · ACI Mater. J. · 2000 · 97 · 637
6. J.Cairns First International Conference on Behaviour of Damaged Structures Rio de Janeiro Brasil 1998.
7. 10.1016/S0950-0618(97)00043-310.1016/S0950-0618(97)00043-3 ↗
8. G.Horrigmoe Concrete Solutions 1st International Conference on Concrete Repair 15–17 July 2003 St. Malo France Proceedings Vol. 1 2003 PP.209–224.
9. B.Elsener D.Flückiger H.Wojtas H.Böhni EVED Bundesamt für Strassenbau VSS‐BerichtNr. 521 1996.
10. 10.1016/0010-938X(91)90048-T10.1016/0010-938X(91)90048-T ↗
11. CEN “Cathodic protection of steel in concrete –Atmospherically exposed concrete” EN 12696‐2000 (March 2000).
12. NACE Standard recommended practice: “Cathodic protection of reinforcing steel in atmospherically exposed concrete structures” NACE Stand RP0290‐90 Item No. 53072 NACE Houston1990.
13. Korrosionskommission “Richtlinien für Projektierung Ausführung und Überwachung des kathodischen Korrosionsschutzes von Stahlbetonbauwerken” C7d Ausgabe 1991 Schweizerische Gesellschaft für Korrosionsschutz (SGK) Technoparkstrasse 1 CH‐8005 Zürich.
14. Highways Agency Advice Note BA83 Cathodic protection for use in reinforced concrete highway structures UK Highway Agency 2002.
15. Halladay M. · Public Roads · 1998 · 61 · 11
16. “Cathodic protection of reinforced concrete bridge elements: A state‐of‐the‐Art report” SHRP‐S‐337 Strategic Highway Research Program Washington DC 1993 p.90.
17. J.Bartholomew J.Bennett Th.Turk D. R.Lankard R.Savinell Criteria and materials performance studies for cathodic protection of reinforced concrete SHRP‐S‐670 Strategic Highway Research Program Washington DC 1993 p.90.
18. Bennett J. E. · Mater. Perform. · 1997 · 36 · 16
19. 10.5006/1.328398910.5006/1.3283989 ↗
20. 10.1061/(ASCE)0899-1561(2000)12:2(164)10.1061/(ASCE)0899-1561(2000)12:2(164) ↗
21. J.Bennett Th.Turk Technical alert – cathodic protection of reinforced concrete bridge elements SHRP‐S‐359 Strategic Highway Research Program Washington DC 1993 p.14.
22. Y.Schiegg M.Büchler M.Brem EUROCORR 2007 Progress by Corrosion Control Freiburg Germany 9–13 September2007.
23. D.Flückiger B.Elsener H.Böhni Chloride im Beton: Transport und Erfassung Eidgenössisches Verkehrs‐ und Energiewirtschaftsdepartement Bundesamt für Strassenbau Forschungsauftrag 82/88 Herausgeber Vereinigung Schweizerischer Strassenfachleute Zürich 1996.
24. ÖNORM B 4706 “Betonbau – Instandsetzung Umbau und Verstärkung” 2003.
25. J.Tritthart Schriftenreihe Straßenforschung Heft 556 Bundesministerium für Verkehr Innovation und Technologie Wien1988 p.117.
26. 10.1179/00070599479826799910.1179/000705994798267999 ↗
27. W.Lukas W.Schwarz G.Hartl Ch.Niederegger Schriftenreihe Straßenforschung Heft 556 Bundesministerium für Verkehr Innovation und Technologie (BMVIT) Wien2006 pp.11–57.