A novel methodology to study localized corrosion under atmospheric simulated corrosion conditions: Toward a continuous monitoring of the corrosion damage on AA2024
Source abstract
Abstract
There is a need to develop instrumented witness plates which would be possible to expose in natural environments after laboratory validation. In conventional laboratory scale test chambers, the main difficulty remains the access of any kind of sensor to the tested metallic target for continuous monitoring. It is proposed to generate a well‐controlled spray by an ultrasonic nozzle focused on the surface of very thin AA2024 foils positioned in a compact test cell which renders possible the access to the backside of the target. Validation in terms of corrosion damage of remote sequential experimental procedure using an ultrasonic nozzle programmed to pulse is illustrated.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Non-Destructive Testing Techniques · Ultrasonics and Acoustic Wave Propagation · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Univ. Bourgogne Franche Comté − ICB UMR CNRS 6303 Faculte Sciences Mirande Dijon 21078 France
References (9)
Show source-provided references
1. 10.1149/1.347372410.1149/1.3473724 ↗
2. 10.1016/j.corsci.2011.05.05510.1016/j.corsci.2011.05.055 ↗
3. 10.1016/j.corsci.2011.06.02810.1016/j.corsci.2011.06.028 ↗
4. 10.1016/j.corsci.2010.11.00510.1016/j.corsci.2010.11.005 ↗
5. M. C.Hebbron P. C.Morgan Patent WO2008125878 (A1)Corrosion sensors 2008.
6. A.Trueman A.Butler J.Hopf J.Jacob presented atAnnual Conference of the Australasian Corrosion Association: Corrosion and Prevention 2014 Darwin Australia 21–24 September 2014 Paper 56 pp.1–11.
7. 10.1016/S0041-624X(01)00054-310.1016/S0041-624X(01)00054-3 ↗
8. 10.1149/2.0951606jes10.1149/2.0951606jes ↗
9. 10.1016/j.electacta.2010.03.00610.1016/j.electacta.2010.03.006 ↗