journal article·2015-12

A lap joint simulant laboratory test method of aluminium alloys

A. Zimmer, R. Oltra, T. M. L. Le

Materials and Corrosion· Volume 66· Issue 12
Publisher page

Abstract

A lap joint simulant cavity (LJSC) with a gap thickness of 200 μm has been developed to test corrosion of assembled coated aluminium alloys. The LJSC was instrumented with electrodes allowing simultaneous pH and potential measurements in 0.5 M NaCl solution. Assuming the outer part of the LJSC is electrochemically inactive (painted sheet) it was confirmed that in free corroding conditions the pH inside the LJSC tends more towards alkalinisation. On the opposite, if the outer part of the LJSC is electrochemically active (unpainted sheet) the pH inside the LJSC tends towards an acidic value.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Anodic Oxide Films and Nanostructures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Laboratoire ICB Equipe EIC, UMR 6303 CNRS – Université de Bourgogne Franche‐Comté 9 avenue A. Savary 21078 Dijon cedex France

References (9)

Show source-provided references
1. Hack T. · 2013 · 3
2. 10.1179/174327804X1321710.1179/174327804X13217 ↗
3. 10.5006/1.327763610.5006/1.3277636 ↗
4. Holroyd N.J. H. · 1987 · 495
5. 10.1179/174327807X15993410.1179/174327807X159934 ↗
6. 10.1002/sia.524710.1002/sia.5247 ↗
7. Dorsett T. · 1993 · 403
8. Sainfort P. · EU Patent EP 0 623 462 B2 · 1998
9. Oltra R. · 2013 · 77