Abstract

Abstract This paper deals with the possible corrosion risk for steel rebars in cracked reinforced concrete structures by using acrylate gels for grouting. In the course of this project, 19 customary acrylate gels were analysed. The results of the conducted test procedures revealed that none of the tested acrylate gels can provide an active corrosion protection for the steel rebars due to their low electrolytic resistivity and low pH values. Just when applied in very thin layers (e.g., fine cracks) it seems to be possible that alkaline components of the surrounding concrete can penetrate through the gel to form a passive layer on the embedded steel rebar.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Structural Behavior of Reinforced Concrete

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (6)

Show source-provided references
1. Schießl P. · Bauingenieur · 1994 · 69 · 439
2. M.Raupach L.Wolff J.Harnisch Institut für Bauforschung Aachen2006 Forschungsbericht Nr. F 934.
3. DIN EN 14498 Produkte und Systeme für den Schutz und die Instandsetzung von Betontragwerken. Prüfverfahren. Änderungen von Volumen und Gewicht nach Wechsel‐Beanspruchung durch Trocknung an der Luft und Lagerung in Wasser; Deutsche Fassung EN 14498:2004.
4. DIN EN 480‐14 Entwurf 01.2005. Zusatzmittel für Beton Mörtel und Einpressmörtel – Prüfverfahren; Bestimmung des Korrosionsfortschritts von Stahl in Beton Elektrochemische Prüfung bei gleich bleibendem Potential.
5. Nürnberger U. · 1995
6. M.Raupach J.Warkus in:16th Internationale Baustofftagung Weimar2006 pp1/1207–1/1214.