journal article·1978-09

Corrosion studies under conditions of thermal desalination I. Pilot test loops for the simulation of plant conditions

R. Manner, E. Heitz

Materials and Corrosion· Volume 29· Issue 9
Publisher page

Abstract

Abstract In a pilot test loop conditions of thermal sea‐water desalination were simulated, i. e., temperatures between room temperature and 120°C, oxygen contents between saturation and 2 ppb, flow velocities up to 6 m/s and various pH values were controlled over a long time with appropriate regulation devices. In two specimen chambers of different design corrosion rates of non alloyed and low alloyed steels were measured and compared by weight loss and polarisation resistance. Good agreement was obtained in 100 hr experiments and short duration parameter studies. This work contains the experimental and methodical requirements for investigation into the influence of oxygen, flow velocity, pH value and impurities during sea‐water desalination which will be presented in part II of the publication.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Membrane Separation Technologies · Membrane-based Ion Separation Techniques · Solar-Powered Water Purification Methods

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (8)

Show source-provided references
1. 10.1002/cite.33044200310.1002/cite.330442003 ↗
2. White R. A. · Mat. Protection · 1965 · 4 · 48
3. 10.1002/cite.33041030410.1002/cite.330410304 ↗
4. Bailie R. E. · Proc. 3rd Europ. Symp. Fresh water from the sea · 1 · 549
5. P. R.Bom:Proc. Marine Corrosion Conference Sea Horse Institute Wrightsville Beach USA Paper 5 1967.
6. Werkstoffe für Meerwasseranlagen International Nickel 1. Aufl. 1968.
7. 10.1002/maco.1976027040610.1002/maco.19760270406 ↗