Corrosion of HR3C heat exchanger alloy in a biomass fired PF utility boiler
Source abstract
Abstract
Detailed microscopic examinations have been conducted on two, temperature-regulated probes (commercial HR3C heat exchanger alloy) after being exposed to biomass flue gas inside a PF boiler for 3770 h at 600°C and 650°C respectively. Corrosion of the tube proceeds via scale formation and internal element depletion. Three characteristic types of internal corrosion have been identified depending on their position relative to the flue gas passage and deposit/flue gas chemistry. Severe, mainly internal corrosion occurs at down-stream locations where higher potassium chloride content exists within the deposit. Corrosion mechanisms corresponding to each type of internal corrosion have been proposed based on further laboratory tests and thermodynamic analysis. The increased temperature (650°C) causes slightly higher material wastage for the alloy.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: High-Temperature Coating Behaviors · Chemical Looping and Thermochemical Processes · Thermochemical Biomass Conversion Processes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References
Reference metadata was not supplied for this record.