journal article·2018-01-25

Effect of extrusion process melt temperature on polyurethane catheter surfaces

B. Clemend Bovas, L. Karunamoorthy, Foo Boon Chuan

Publisher page

Abstract

Determination of optimum process melt temperature of medical-grade polyurethane (PU) is an indispensable challenge witnessed during the catheter manufacturing process. This resin does not contain a uniform crystal structure but exists in an amorphous state. The lower shore hardness PU material, used in catheter manufacture, has just a “melt temperature range” instead of a definite melt temperature. This temperature plays a significant role in shaping the catheter surfaces, which directly interact with human tissues and cause health-care-associated issues. The objective of this work is to evaluate the effects of variations in the melt temperature during the extrusion process of medical catheters on their outer surfaces. Medical PU, Pellethane, was used for this study and 12 Fr (4.0 mm) catheters were manufactured with optimal validated parameters, excluding melt temperature. The manufactured catheters were examined under Optical Microscopy and Atomic Force Microscopy (AFM) for surface topography studies. Wettability studies were carried out using a Goniometer for evaluating the water contact angles. The effects of melt temperature on the surface roughness (Ra) and wettability of the catheter surfaces were analyzed through analysis of variance (ANOVA). The conclusion was that the process melt temperature variations have a significant effect on catheter Ra and its wettability characteristics.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Injection Molding Process and Properties · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering, CEG, Anna University, Chennai, Tamil Nadu, India

Manufacturing Section, Forefront Medical Technology Pte., Ltd., Singapore

References (26)

Show source-provided references
1. Rivera A.M. · Acta Anaesthesiologica Belgica · 2005 · 56 · 271
2. 10.1002/jbm.a.3583710.1002/jbm.a.35837 ↗
3. 10.1080/10426914.2010.53033010.1080/10426914.2010.530330 ↗
4. 10.1080/1042691090297968610.1080/10426910902979686 ↗
5. 10.1080/1042691090297955310.1080/10426910902979553 ↗
6. 10.1177/00952443710030030210.1177/009524437100300302 ↗
7. 10.1080/1042691050046472710.1080/10426910500464727 ↗
8. 10.1002/pen.1015810.1002/pen.10158 ↗
9. 10.1016/j.ejca.2016.02.01110.1016/j.ejca.2016.02.011 ↗
10. 10.1080/1042691090302239510.1080/10426910903022395 ↗
11. 10.1016/S0142-9612(03)00450-210.1016/S0142-9612(03)00450-2 ↗
12. 10.1007/s11998-015-9658-310.1007/s11998-015-9658-3 ↗
13. 10.1007/s00542-005-0602-910.1007/s00542-005-0602-9 ↗
14. 10.5897/AJMR2016.817810.5897/AJMR2016.8178 ↗
15. 10.1002/(SICI)1097-4636(199621)33:1<29::AID-JBM5>3.0.CO;2-O10.1002/(SICI)1097-4636(199621)33:1<29::AID-JBM5>3.0.CO;2-O ↗
16. 10.1016/0142-9612(93)90150-Z10.1016/0142-9612(93)90150-Z ↗
17. 10.1016/j.biomaterials.2003.08.01110.1016/j.biomaterials.2003.08.011 ↗
18. 10.1016/j.triboint.2005.10.01010.1016/j.triboint.2005.10.010 ↗
19. 10.1007/s10856-007-3339-410.1007/s10856-007-3339-4 ↗
20. 10.1007/s10856-006-0618-410.1007/s10856-006-0618-4 ↗
21. 10.14314/polimery.2013.84710.14314/polimery.2013.847 ↗
22. Rauwendaal, C. Polymer Extrusion; Hanser Publishers: Munich, Germany, 2014; p. 629.10.3139/9781569905395 ↗
23. 10.1016/j.applthermaleng.2012.04.01310.1016/j.applthermaleng.2012.04.013 ↗
24. Anonymous.Lubrizol Extrusion Guide. Cleveland, OH: The Lubrizol Corporation, 2014; p. 3.10.1016/S1351-4210(14)70167-2 ↗
25. 10.3139/217.301110.3139/217.3011 ↗
26. 10.1016/j.polymer.2014.12.01410.1016/j.polymer.2014.12.014 ↗