Erratum to: Numerical damage prediction in dowel connections of wooden structures
Source abstract
Abstract
My;Rk 1⁄4 0:3 fu;k d where My;Rk is the fastener yield moment, fu;k is the characteristic tensile strength, and d is the bolt diameter. Because of this error, one result is wrong in Table 4 (see below), from where the authors claimed that the analytical procedure of EC 5 [1] leads to an 82.7 % underestimation of the connection strength with respect to the experimental result. For steel-timber connections using multiple fasteners subjected to a loading parallel to grain near the end of the timber member, the characteristic load-carrying capacity of fracture along the perimeter of the fastener area, which can be caused either by block shear failure or by plug shear failure, should read:
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Civil and Structural Engineering Research · Structural Analysis of Composite Materials · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References
Reference metadata was not supplied for this record.