Strength design guidelines for fastenings in concrete-Revisited
Source abstract
Abstract
The paper shows that the method adopted in the CEB Design Guide (hereinafter “DG”) [1] for strength design of fastening in concrete should be extended by inclusion of a number of important factors. In strength design for cone failure or local blow-out failure of the concrete, in distinction from DG, allowance is recommended for the size effect which—as is known-determines the transition from the pseudoplastic to the brittle mode with increase of the height of the failure cone. The resulting improvement is estimated. Allowance is also recommended for the critical stress intensity factor K1c, which should replace the square root of concrete compressive strength ( $$\sqrt {f_c } $$ ) resorted to in DG. It is shown that use of the latter for different concretes makes for errors. On the basis of experimental data, formulas incorporating the two factors were obtained for different element geometries—including the case (not discussed in DG) of a flat element loaded in its plane of symmetry. The above circumstances should be taken into consideration in using the Guide at present and in its revision in future.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Fire effects on concrete materials · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Comité Euro-International du Béton, ‘Design of Fastenings in Concrete, Design Guide’, CEB (Thomas Telford, London, 1997).
2. Yagust, V.I., ‘Resistance to development of crack in concrete structures taking into account the influence of material macrostructure’, D.Sc. thesis (NIIZhB, Moscow, 1982) [only available in Russian].
3. Shapiro, G.I. and Yagust, V.I., ‘Strength of plane concrete element under concentrated load’, in ‘Investigation of Bearing Concrete and Reinforced Concrete Structures of Multistory Precast Buildings’, eds. G.N. Lvov and J.M. Strugatsky (MNIITEP, Moscow, 1980), 74–111 [only available in Russian].
4. Comité Euro-International du Béton, ‘Fastenings to Reinforced Concrete and Masonry Structures’, Bulletin d'Information, No206 (CEB, 1991).
5. Entov, V.M. and Yagust, V.I., ‘Experimental investigation of the laws governing quasi-static development of macrocracks in concrete’,Mechanics Solids [translation from Russian]10 (4) (1975) 87–95.
6. Yagust, V.I., ‘Application of the model of Leonov-Panasuk-Dugdale for evaluation of crack development in concrete structures’, in ‘Strength Investigations of Bearing Structures of Multistory Precast Buildings’, (eds. G.N. Lvov and J.M. Strugatsky, MNIITEP, Moscow, 1983), 66–84 [only available in Russian].
7. Bažant, Z.P. and Planas, J., ‘Fracture and size effect in concrete and other quasibrittle materials’ (1997).
8. Barenblatt, G.I., ‘The mathematical theory of equilibrium cracks in brittle fracture’,Advances in Appl. Mech. 7 (1962) 55–129.10.1016/S0065-2156(08)70121-2 ↗
9. Dugdale, D.S., ‘Yielding of steel sheets containing slits’,J. of Mech. and Phys. of Solids 8 (1960) 100–108.10.1016/0022-5096(60)90013-2 ↗
10. Panasyuk, V.V., ‘The Limit Equilibrium of the Brittle Solids with Cracks’, (Kiev, 1968), [only available in Russian].
11. Eligehausen, R. and Sawade, G., ‘A fracture mechanics based description of the pull-out behavior of headed studs embedded in concrete’, in ‘Fracture Mechanics of Concrete Structures. From Theory to Application’ (ed. L. Elfgren, London, 1989) 281–299.
12. Skramtaev, B.G. and Wolf, I.V., ‘Control of the concrete strength’ (Moscow, 1939) [only available in Russian].
13. Kononov, I.A. ‘The embedment depth determination’, in ‘Vibration Application in Building’, (ed. I.J. Petrov, Moscow, 1962) 31–65 [only available in Russian].
14. Sattler, K., ‘Examination of new joint anchors’,Der Bauingenieur 37 (1) (1962) 1–8, only available in German.
15. Lukojanov, U.N., ‘The experimental study of behavior concrete in anchor fastenings’, in ‘Design and Construction of Industrial Buildings and Constructions’, (ed. V.G. Desjatov, Moscow, 1964) 18–27 [only available in Russian].
16. Nizhnikovsky, G.S., ‘The new type of anchor bolt joining’, ‘Express Information’, 149 (Moscow, 1964) [only available in Russian].
17. Holmjansky, M.M., ‘The Laying Details of Precast Reinforced Concrete Structure’ (Moscow, 1968) [only available in Russian].
18. Tchujko, P.A., ‘The study of concrete strength by method of cone failure and shear failure’, in ‘The Interbranch Problems of Building. Home Experience’, (ed. D.A. Korshunov CINIS, Moscow, 1972) [only available in Russian].
19. Zhao, G., ‘Resistance of undercut anchor situated far from a specimen edge in case of concrete cone failure’, in ‘Deutscher Ausschuss für Stahlbeton’, H.454 (1995) [only available in German].
20. Yagust, V.I. and Yankelevsky, D.Z., ‘Strength of a concrete element under the action of concentrated tensile or shear force’, in ‘Fracture Mechanics of Concrete Structure’, Proc. of the 2nd Intern. Conf. on Fracture Mechanics of Concrete Structures (FRAMCOS 2), V. 2, Zurich, Switzerland, July 25–28, 1995 (1995) 1361–1368.
21. Bažant, Z.P., ‘Size effect of blunt fracture: concrete, rock, metal’,J. of Eng. Mech. 110(4) (1984), 518–535.10.1061/(ASCE)0733-9399(1984)110:4(518) ↗
22. Ueda, T., Stitmannaithum, B. and Matupayont, S., ‘Experimental investigation on shear strength of bolt anchorage group’,ACI Structural Journal 88 (3) (1991) 292–300.
23. Fuchs, W., ‘Fastening behavior under shear load in uncracked concrete’, in ‘Deutscher Ausschuss für Stahlbeton’, H.425 (1992) [only available in German].
24. Comité Euro-International du Béton, ‘CEB-FIP Model Code 1990’, CEB, Bulletin d'Information, No203 (1991).