journal article·2019-11Open access

Mechanical properties of replicated cellular Zn and Zn1.5Mg in uniaxial compression

Karel Lietaert, Joop van Deursen, Thomas Lapauw, Ludger Weber, Andreas Mortensen, Jozef Vleugels

Abstract

Abstract We present here a study of the mechanical behavior of cellular Zn and Zn1.5Mg with densities between 11.9 and 24.5%, produced by replication processing using NaCl as a spaceholder. Cellular Zn and Zn1.5Mg deform homogeneously during quasi-static compression. The plateau stress scales with the relative density according to a power-law of exponent of 2.8 for both materials; recorded values are 6.0 ± 0.6 MPa for cellular Zn of relative density 24% and 10.0 ± 0.5 MPa for cellular Zn1.5Mg of relative density 23%. In ambient-temperature creep tests with loads up to 50% of the plateau stress, after more than 70 h deformation remains negligible (in the range of experimental error). This observation, coupled with other measured mechanical properties, indicates that replicated cellular Zn and Zn1.5Mg are viable materials in the context of their application as a low load-bearing implant material.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (42)

Show source-provided references
1. Updates on the research and development of absorbable metals for biomedical applications10.1007/s40204-018-0091-4 ↗
2. Delayed foreign body reaction caused by bioabsorbable plates used for maxillofacial fractures10.5999/aps.2016.43.1.40 ↗
3. Safety and performance of the DRug-Eluting Absorbable Metal Scaffold (DREAMS) in patients with de novo coronary lesions: 3-year results of the prospective, multicentre, first-in-man BIOSOLVE-I trial
4. Magnesium-based compression screws: a novelty in the clinical use of implants10.1007/s11837-015-1773-1 ↗
5. Long-term clinical study and multiscale analysis of in vivo biodegradation mechanism of Mg alloy10.1073/pnas.1518238113 ↗
6. In vivo evaluation of a magnesium-based degradable intramedullary nailing system in a sheep model10.1016/j.actbio.2015.07.025 ↗
7. Biocompatibility and degradation of LAE442-based magnesium alloys after implantation of up to 3.5 years in a rabbit model10.1016/j.actbio.2016.08.002 ↗
8. Gadolinium accumulation in organs of Sprague–Dawley® rats after implantation of a biodegradable magnesium-gadolinium alloy10.1016/j.actbio.2016.11.024 ↗
9. Metallic powder-bed based 3D printing of cellular scaffolds for orthopaedic implants: a state-of-the-art review on manufacturing, topological design, mechanical properties and biocompatibility10.1016/j.msec.2017.02.094 ↗
10. Replication processing of highly porous materials10.1002/adem.200600077 ↗
11. Goodall · 2013 · vol. 24
12. Baez Pimiento · 2013
13. Mechanical properties and in vitro biodegradation of newly developed porous Zn scaffolds for biomedical applications10.1016/j.matdes.2016.06.080 ↗
14. Constitutive relation for ambient-temperature creep in hexagonal close-packed metals10.2320/matertrans.M2009223 ↗
15. Structural, mechanical and cytotoxicity characterization of as-cast biodegradable Zn-xMg (x=0.8-8.3%) alloys
16. Micro-alloying with Mn in Zn–mg alloy for future biodegradable metals application10.1016/j.matdes.2015.12.128 ↗
17. Measuring and tailoring capillary forces during liquid metal infiltration10.1016/j.cossms.2006.02.007 ↗
18. A threshold selection method from gray-level histograms10.1109/TSMC.1979.4310076 ↗
19. ISO · 2011
20. Guidelines for assessment of bone microstructure in rodents using micro–computed tomography10.1002/jbmr.141 ↗
21. Solidification of binary hypoeutectic alloy matrix composite castings10.1007/BF02648949 ↗
22. Solidification of Al-4.5 wt pct Cu-replicated foams10.1007/s11661-010-0297-0 ↗
23. National Physics Laboratory UK
24. Solidification microstructure selection and characteristics in the zinc-based ZnMg system10.1016/0956-7151(92)90298-S ↗
25. Origin of spiral eutectic structures10.1016/0001-6160(54)90158-3 ↗
26. Synthesis of biodegradable Zn-based scaffolds using NaCl templates: relationship between porosity, compressive properties and degradation behavior10.1016/j.matchar.2018.01.033 ↗
27. Open cellular magnesium alloys for biodegradable orthopaedic implants10.1016/j.jma.2013.11.004 ↗
28. Precise fabrication of open porous mg scaffolds using NaCl templates: relationship between space holder particles, pore characteristics and mechanical behavior10.1016/j.matdes.2017.11.064 ↗
29. Modelling the mechanical behavior of cellular materials10.1016/0921-5093(89)90154-8 ↗
30. Uniaxial deformation of microcellular metals10.1016/j.actamat.2006.03.054 ↗
31. On the steady-state creep of microcellular metals10.1016/j.scriptamat.2007.03.013 ↗
32. Deformation of open-cell aluminum foam10.1016/S1359-6454(01)00294-4 ↗
33. Density dependence of the compressive properties of porous copper over a wide density range10.1016/j.actamat.2006.11.024 ↗
34. Scaling of conductivity and Young's modulus in replicated microcellular materials10.1007/s10853-013-7626-9 ↗
35. Spherical pore replicated microcellular aluminium: processing and influence on properties10.1016/j.msea.2007.02.002 ↗
36. Processing of magnesium porous structures by infiltration casting for biomedical applications10.1002/adem.201300236 ↗
37. Kemper · 2007
38. J. J. Mecholsky Jr and S. R. Powell Jr, Fractography of Ceramic and Metal Failures. ASTM International, 1984.10.1520/STP827-EB ↗
39. Mechanical and corrosion properties of newly developed biodegradable Zn-based alloys for bone fixation10.1016/j.actbio.2011.05.008 ↗
40. Biodegradable metals for cardiovascular stents: from clinical concerns to recent Zn-alloys10.1002/adhm.201501019 ↗
41. Plastic deformation of the intermetallic compound MgZn210.1002/pssb.19670240107 ↗
42. Compressive creep behavior of bovine trabecular bone10.1016/0021-9290(94)90006-X ↗