Correcting intensity loss errors in the absence of texture-free reference samples during pole figure measurement

Ahmed A. Saleh, Viet Q. Vu, Azdiar A. Gazder

Abstract

Abstract Even with the use of X-ray polycapillary lenses, sample tilting during pole figure measurement results in a decrease in the recorded X-ray intensity. The magnitude of this error is affected by the sample size and/or the finite detector size. These errors can be typically corrected by measuring the intensity loss as a function of the tilt angle using a texture-free reference sample (ideally made of the same alloy as the investigated material). Since texture-free reference samples are not readily available for all alloys, the present study employs an empirical procedure to estimate the correction curve for a particular experimental configuration. It involves the use of real texture-free reference samples that pre-exist in any X-ray diffraction laboratory to first establish the empirical correlations between X-ray intensity, sample tilt and their Bragg angles and thereafter generate correction curves for any Bragg angle. It will be shown that the empirically corrected textures are in very good agreement with the experimentally corrected ones.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Microstructure and Mechanical Properties of Steels · Advanced X-ray Imaging Techniques · X-ray Spectroscopy and Fluorescence Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. Introduction to texture analysis: macrotexture, microtexture and orientation mapping
2. X-ray thin film measurement techniques VII. Pole figure measurement
3. Defocusing for the Schulz technique of determining preferred orientation10.1063/1.1658393 ↗
4. Use of polycapillary X-ray lenses in the X-ray diffraction measurement of texture10.1107/S0021889802000481 ↗
5. Analysis of certain errors in the X-ray reflection method for the quantitative determination of preferred orientations10.1063/1.1702204 ↗
6. The effect of X-ray linewidth on the defocus correction in the Schulz reflection technique for texture measurement10.1063/1.324154 ↗
7. To the reliability of X-ray texture measurements: important parameters, measuring strategies, scatter bands and comparative measurements with different systems10.1002/(SICI)1521-4052(199902)30:2<77::AID-MAWE77>3.0.CO;2-A ↗
8. Background errors in X-ray diffraction parameters10.1088/0508-3443/17/10/310 ↗
9. Influence of instrumental aberrations on the Schultz technique for the measurement of pole figures10.1088/0508-3443/11/3/302 ↗
10. A method for obtaining the complete pole figure with a single sample using the Schulz technique10.1155/TSM.4.159 ↗
11. Influence of the sample radius and irradiated zone width on the defocusing phenomenon in the Schulz technique10.1016/0025-5416(82)90166-5 ↗
12. Multicapillary optics for materials science studies10.4028/www.scientific.net/MSF.321-324.162 ↗
13. Polycapillary optics for materials science studies: instrumental effects and their correction10.6028/jres.109.003 ↗
14. X-ray optics for materials research10.4028/www.scientific.net/MSF.278-281.227 ↗
15. Microstructure and texture evolution in a twinning-induced-plasticity steel during uniaxial tension10.1016/j.actamat.2013.01.051 ↗
16. Intensity correction in texture measurement of polycrystalline thin films by X-ray diffraction10.1080/07303300310001597035 ↗