journal article·2025-02-01Open access

Assessing moisture content in XLPE power cables using frequency-dependent tangent delta measurements

Babu Naik Gugulothu, Sanjay Lakshminarayanan, Madhu Palati, Suresh Haleyur Lakshmegowda, Mahipal Bukya

Materials Research Express· Volume 12· Issue 2

Abstract

Abstract The reliability of cross-linked polyethylene (XLPE)-insulated power cables, mostly used for electricity distribution and transmission in urban areas, is often compromised due to the lack of effective condition-based monitoring systems. This leads to difficulties in early fault detection and increased risk of unscheduled outages, and failures, particularly in cable end terminations. This research aims to develop a robust and accurate methodology for estimating moisture content in XLPE cable end terminations to enhance condition-based monitoring and ensure reliable power delivery. The study employed frequency domain spectroscopy to examine the dielectric properties of XLPE cable samples with varying moisture content levels. A novel predictive formula was derived to estimate moisture content using dielectric frequency response (DFR) supported by validation through sweep frequency response analysis (SFRA) tests. We conduct an experiment to estimate the moisture content and observe satisfactory agreement between the experimental and theoretical values. The proposed method achieved a high accuracy of 96%; the percentage error variation was minimal in moisture estimation, outperforming existing techniques. This study provides a practical and reliable approach for monitoring XLPE cable condition, particularly at end terminations. The proposed methodology ensures accurate moisture content estimation, enabling early fault detection and reducing the risk of unscheduled outages. This advancement has major implications for enhancing the reliability and efficiency of urban power systems.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: High voltage insulation and dielectric phenomena · Thermal Analysis in Power Transmission · Microwave and Dielectric Measurement Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. The measurement of very low conductivity and dielectric loss in XLPE cables: a possible method to detect degradation due to thermal aging10.1109/TDEI.2011.6032823 ↗
2. Interpretation of dielectric loss data on service aged polyethylene based power cable systems using VLF test methods10.1109/TDEI.2013.6633700 ↗
3. Dielectrical parameters and relaxation of Al/NFT/p-Si schottky diode with frequency dependence10.14744/sigma.2023.00009 ↗
4. Chitosan-poly (N, N-dimethylacrylamide-co-diallyl dimethyl ammonium chloride) and chitosan-poly (N, N-dimethylacrylamide) SEMI-IPN films: the comparison of their properties
5. Droplet motion driven by liquid dielectrophoresis in the low-frequency range10.3390/mi15010151 ↗
6. Fano resonances in all-dielectric nanostructures. In all-dielectric
7. Condition assessment of XLPE insulated cables based on polarization/depolarization current method10.1109/TDEI.2015.004782 ↗
8. Use of dissipation factor for life consumption assessment and future life modeling of oil-filled high-voltage power cables10.1109/MEI.2012.6130529 ↗
9. On-site diagnostics of medium-voltage underground cross-linked polyethylene cables10.1109/MEI.2011.5954067 ↗
10. A new method of aging assessment for XLPE cable insulation based on dielectric response
11. Insulation evaluation of MV underground cable with partial discharge and dielectric dissipation factor measurements10.1016/j.epsr.2023.109338 ↗
12. Parameters identification for extended debye model of XLPE cables based on sparsity-promoting dynamic mode decomposition method10.32604/ee.2023.028620 ↗
13. A review of the factors that influence aging and degradation in crosslinked polyethylene (XLPE) polyolefin10.1016/j.matpr.2023.10.095 ↗
14. Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review10.1007/s00202-023-01935-y ↗
15. Nonconventional measurements on insulation materials high voltage bushings and power cables using frequency response analysis method10.1002/eng2.12136 ↗
16. Study on detection for the defects of XLPE cable lines10.1109/61.489320 ↗
17. Monitoring and digitalization technologies for HV power cable systems
18. Recognition of partial discharge defects in cable terminations10.1109/CMD.2008.4580513 ↗
19. A novel method to improve the residual life of switchgear by reducing the impact caused by thermal and mechanical stresses produced due to SLG cable faults in electrical substations10.37934/arfmts.106.2.6877 ↗
20. Williams · Cable Accessory Failure Analysis · 2010
21. Use of tan δ and partial discharge for evaluating the cable termination assembly10.3390/en13205299 ↗
22. Diagnosis of moisture in oil/paper distribution Cables-I: estimation of moisture content using frequency-domain spectroscopy10.1109/TPWRD.2003.820417 ↗
23. Dielectric spectroscopy in time and frequency domain for HV power equipment. I. Theoretical considerations10.1109/MEI.2003.1238713 ↗
24. Recent trends in the condition monitoring of transformers10.1007/978-1-4471-5550-8 ↗
25. Modeling of dielectric dissipation factor measurement for XLPE cable based on Davidson-Cole model10.1109/TDEI.2019.007784 ↗
26. Method for identifying ageing in epoxy-mica composite insulation used in rotational machines through modelling of dielectric relaxation10.1049/hve.2019.0111 ↗
27. Estimation of moisture content in XLPE cable insulation using electric modulus10.1109/TDEI.2022.3173485 ↗
28. Estimation of paper moisture content based on dielectric dissipation factor of oil-paper insulation under non-sinusoidal excitations10.1109/TDEI.2015.7076781 ↗
29. Mechanisms causing nonlinear dielectric response of water treed XLPE cables10.1109/ICSD.1998.709230 ↗
30. A variable frequency model of a transformer bushing with localised moisture content10.1109/CEIDP.2012.6378817 ↗
31. Water tree initiation and growth in XLPE cables under static and dynamic mechanical stress10.1109/ELINSL.2012.6251546 ↗
32. Removal of chlorides and hardness from contaminated water by using various biosorbents: a comprehensive review10.1016/j.wen.2024.01.003 ↗
33. Estimation of moisture content in XLPE insulation in medium voltage cable by frequency domain spectroscopy10.1109/TDEI.2020.008789 ↗
34. SFRA ability to find out fault inside the winding: a practical case study10.21817/ijet/2020/v12i2/201202019 ↗
35. Interpretation of sweep frequency response data (SFRA) using graphical and statistical technique10.1109/ICECA.2017.8212810 ↗
36. A practical case study on effect of moisture ingress in power cables and methods to reduce equipment failure10.1088/2631-8695/ada5a9 ↗
37. A study of XLPE insulation failure in power cables under electromagnetic stress10.1088/2631-8695/ad7443 ↗