Corrosion Resistance Evaluation of HVOF Produced Hydroxyapatite and TiO2-hydroxyapatite Coatings in Hanks' Solution
Source abstract
Abstract
The electrochemical behavior of HVOF produced hydroxyapatite (HA) and 80HA-20TiO 2 coatings were investigated using electrochemical techniques in natural aerated Hanks' solution in the presence and absence of bovine serum albumin (BSA) for 30 days. All samples presented open circuit potential oscillations, which were associated to the porous nature of the coating that allows the electrolyte reaches the substrate causing activation -passivation at the bottom of the pores. The polarization studies indicated that the 80HA-20TiO 2 coating was the only one that showed a narrow potential passive region from around -0.4 V to 0 V in the presence and absence of BSA, indicating the beneficial influence of the addition of TiO 2 to the HA coating stability. Our results indicated that BSA in Hanks' solution diminishes the stability of the metallic oxide layer present on the Ti-based alloy accelerating the degrading of hydroxyapatites coatings / substrate interface due to its chelating ability.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Corrosion Behavior and Inhibition · Bone Tissue Engineering Materials · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Universitat de Barcelona, Spain
Universidade Federal da Grande Dourados - UFGD, Brazil
Universidade Estadual Paulista - UNESP, Brazil
References (43)
Show source-provided references
1. The passivation of alloys on titanium bases10.1016/0013-4686(74)85012-7 ↗
2. Mechanical characterization of brushite and hydroxyapatite cements10.1016/S0142-9612(01)00041-2 ↗
3. Osteointegration of femoral stem prostheses with a bilayered calcium phosphate coating10.1016/j.biomaterials.2005.07.039 ↗
4. Tribological characterization of biocompatible HAp-TiO2 coatings obtained by high velocity oxy-fuel spray10.1016/j.wear.2013.05.009 ↗
5. On the toughness enhancement in hydroxyapatite-based composites10.1016/j.actamat.2013.05.013 ↗
6. Dopamine-assisted immobilization of hydroxyapatite nanoparticles and RGD peptides to improve the osteoconductivity of titanium.10.1002/jbm.a.34376 ↗
7. Characterization and corrosion behavior of hydroxyapatite coatings on Ti6Al4V fabricated by electrophoretic deposition10.1016/j.apsusc.2009.02.086 ↗
8. Influence of spraying parameters on the electrochemical behaviour of HVOF thermally sprayed stainless steel coatings in 3. 4% NaCl10.1016/j.surfcoat.2005.02.116 ↗
9. Adhesion and microstructural characterization of plasma-sprayed hydroxyapatite/glass ceramic coatings onto Ti-6A1-4V substrates10.1016/S0257-8972(97)00576-8 ↗
10. HVOF spraying of nanostructured hydroxyapatite for biomedical applications10.1016/j.msea.2005.01.037 ↗
11. Periodic crystallization effect in the surface layers of coatings during plasma spraying of hydroxyapatite10.1016/0142-9612(93)90158-X ↗
12. Microstructural characterization of hydroxyapatite coating on titanium
13. Effect of different surface finishing and of hydroxyapatite coatings on passive and corrosion current of Ti6Al4V alloy in simulated physiological solution10.1016/S0142-9612(96)00205-0 ↗
14. Deposition of layered bioceramic hydroxyapatite/TiO2 coatings on titanium alloys using a hybrid technique of micro-arc oxidation and electrophoresis10.1016/S0257-8972(99)00612-X ↗
15. Corrosion behavior of titanium in the presence of calcium phosphate and serum proteins10.1016/j.biomaterials.2005.05.047 ↗
16. In vitro corrosion behavior of electrodeposited calcium phosphate coatings on Ti6Al4V substrates10.1007/s10008-012-1742-3 ↗
17. Hydroxyapatite-anatase-carbon nanotube nanocomposite coatings fabricated by electrophoretic codeposition for biomedical applications
18. Characterisation and corrosion resistance of the electrodeposited hydroxyapatite and bovine serum albumin/hydroxyapatite films on Ti-6Al-4V-1Zr alloy surface10.1016/j.corsci.2010.11.033 ↗
19. Electrochemical behavior of cold sprayed hydroxyapatite/titanium composite in Hanks' solution10.1016/j.electacta.2012.01.018 ↗
20. Fabrication, characterization and wear corrosion testing of bioactive hydroxyapatite/nano-TiO2 composite coatings on anodic Ti-6Al-4V substrate for biomedical applications10.1016/j.mseb.2012.03.034 ↗
21. Argon atmospheric plasma sprayed hydroxyapatite/Ti composite coating for biomedical applications10.1016/j.surfcoat.2012.07.009 ↗
22. Characterization and corrosion resistance of plasma sprayed HA and HA-SiO2 coatings on Ti-6Al-4V10.1016/j.surfcoat.2013.04.036 ↗
23. The influence of proteins on the fretting-corrosion behaviour of a Ti6Al4V alloy10.1016/j.wear.2006.03.032 ↗
24. Equivalent circuit for modelling the steel-concrete interface. II. Complications in applying the stern-geary equation to corrosion rate determinations10.1016/S0010-938X(98)00037-7 ↗
25. Effect of hydroxyapatite thickness on metal ion release from Ti6Al4V substrates10.1016/0142-9612(96)89655-4 ↗
26. Degradation characteristics of hydroxyapatite coatings on orthopaedic TiAlV in simulated physiological media investigated by electrochemical impedance spectroscopy10.1016/S0142-9612(03)00362-4 ↗
27. Barsoukov E · 2005
28. Orazem ME · 2012
29. Lvovich VF · 2012
30. Nanostructural Characteristics of Vacuum Cold-Sprayed Hydroxyapatite/Graphene-Nanosheet Coatings for Biomedical Applications10.1007/s11666-014-0069-2 ↗
31. Hydroxyapatite/graphene-nanosheet composite coatings deposited by vacuum cold spraying for biomedical applications: Inherited nanostructures and enhanced properties10.1016/j.carbon.2013.09.088 ↗
32. Hydroxyapatite coatings electrodeposited at near-physiological conditions10.1016/j.matlet.2013.12.091 ↗
33. Plasma sprayed hydroxyapatite coatings: Understanding process relationships using design of experiment analysis10.1016/j.surfcoat.2015.10.044 ↗
34. Structure and composition of passive titanium oxide films10.1016/S0921-5107(97)00043-3 ↗
35. Human Serum Albumin Adsorption on TiO2 from Single Protein Solutions and from Plasma10.1021/la049158d ↗
36. The electrochemical behavior of Ti-6Al-7Nb alloy with and without plasma-sprayed hydroxyapatite coating in Hank's solution10.1002/jbm.10351 ↗
37. A study of the potentials achieved during mechanical abrasion and the repassivation rate of titanium and Ti6Al4V in inorganic buffer solutions and bovine serum10.1016/j.electacta.2004.07.024 ↗
38. Passive film on orthopaedic TiAlV alloy formed in physiological solution investigated by X-ray photoelectron spectroscopy10.1016/S0142-9612(00)00145-9 ↗
39. Scratch resistance and electrochemical corrosion behavior of hydroxyapatite coatings on Ti6Al4V in simulated physiological media10.1007/s10800-012-0504-3 ↗
40. Corrosion behaviour and bioactivity of electrophoretically deposited hydroxyapatite on titanium in physiological media (Hanks' solution)
41. Caracterización de nuevos recubrimientos biocompatibles de hidroxiapatita-TiO2 obtenidos mediante Proyección Térmica de Alta Velocidad10.3989/cyv.082011 ↗
42. Nanostructured Hydroxyapatite Coatings for Improved Adhesion and Corrosion Resistance for Medical Implants10.1557/PROC-703-V7.5 ↗
43. Thermal and chemical modification of titanium-aluminum-vanadium implant materials: effects on surface properties, glycoprotein adsorption, and MG63 cell attachment10.1016/j.biomaterials.2003.10.029 ↗