Corrodibility and Adherence of Reinforced Concrete Rebars Electroplated with Zinc and Zinc-Nickel Alloys
Source abstract
Abstract
Reinforced concrete is the main structural material used in the world in the construction of bridges, roads and commercial and residential buildings. One effective method for preventing corrosion of steel reinforcement is the application of galvanic coatings to the reinforcement itself. The present study evaluated the performance of three groups of reinforcing steel bars (black steel, used as a reference and rebars electroplated with Zinc and Zinc-Nickel alloys) to corrosion and adherence to the concrete matrix. For the analysis of corrosion, the specimens were subjected to two different accelerated corrosion tests: salt spray exposure and wet and dry semi-cycles. The corrosion potential was measured for the qualitative monitoring of the corrosion process and the corrosion rate was estimated. In order to evaluate the steel-concrete adherence, the pullout test was used, in accordance with RILEM-CEB-FIP. The results showed that Zinc and Zinc-Nickel coatings increased the durability of the reinforcing bars and the accelerated corrosion test of wetting and drying cycles proved to be more aggressive compared to the salt spray method to evaluate the corrosion process in the reinforced concrete specimens. Additionally, galvanized reinforcement reduced adherence to the concrete matrix.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Universidade Federal da Bahia, Brasil
Universidade Estadual de Feira de Santana, Brasil
References (39)
Show source-provided references
1. Koch GH · 2002
2. The integration of EIS parameters and bulk matrix characteristics in studying reinforced cement-based materials
3. V Gentil · 2007
4. Ribeiro DV · 2018
5. Effects of FRP Reinforcement Ratio and Concrete Strength on Flexural Behavior of Concrete Beams10.1061/(ASCE)1090-0268(1998)2:1(7) ↗
6. Langill TJ · 2004 · 87
7. Swamy RN · 2004 · 31
8. Yeomans SR · 2004 · 1
9. Performance of Black, Galvanized, and Epoxy-Coated Reinforcing Steel in Chloride-Contaminated Concrete10.5006/1.3293496 ↗
10. Broomfield JP · 2004 · 27110.1016/B978-008044511-3/50025-6 ↗
11. Yeomans SR · 2004 · 145
12. Corrosion behaviour of zinc-nickel coatings, electrodeposited on steel
13. Electrodeposition of single gamma phased Zn-Ni alloy coatings from additive-free acidic bath10.1016/j.apsusc.2014.05.127 ↗
14. Electrodeposited zinc alloy coatings10.1016/0010-938X(93)90345-H ↗
15. Jesus MD · 2009 · 112
16. Zempulski LN · 2007 · 21 p
17. Freire KRR · 2005 · 132 p
18. Corrosion Behaviour of Stainless Steel 304 Electroplated with Zinc Followed by Blue Passivation10.4152/pea.201104295 ↗
19. The corrosion resistance of zinc-nickel composite coatings
20. A new method for pull out test of reinforcing bars in plain and fibre reinforced concrete10.1016/j.engstruct.2018.02.080 ↗
21. Kim JK · 1998
22. Caetano LF · 2008 · 178 p
23. Effect of rebar coating on corrosion resistance and bond strength of reinforced concrete10.1016/j.conbuildmat.2004.07.006 ↗
24. Bond of ribbed galvanized reinforcing steel in concrete10.1016/S0958-9465(00)00049-4 ↗
25. Corrosion resistance of a Zn–Ni electrodeposited alloy obtained with a controlled electrolyte flow and gelatin additive10.1016/j.surfcoat.2006.06.006 ↗
26. Corrosion resistance and microstructure of electrodeposited Zn and Zn alloy coatings10.1016/S0257-8972(96)03125-8 ↗
27. Effect of the addition of red mud on the corrosion parameters of reinforced concrete10.1016/j.cemconres.2011.09.002 ↗
28. Santos L · 2006 · 161
29. Bauer E · 1995 · 236
30. Rocha FC · 2012 · 132
31. 1983
32. Considerations on reproducibility of potential and corrosion rate measurements in reinforced concrete10.1016/j.corsci.2004.02.003 ↗
33. The behavior of galvanized steel in chloride-containing alkaline-solutions-I. The influence of the cation10.1016/0010-938X(90)90046-8 ↗
34. Corrosion behaviour in concrete of three differently galvanized steel bars10.1016/j.cemconcomp.2006.01.011 ↗
35. Equilibria of the chemical composition of the concrete pore solution. Part 1: Comparative study of synthetic and extracted solutions10.1016/0008-8846(87)90100-1 ↗
36. Andrade C · 2004 · 11110.1016/B978-008044511-3/50020-7 ↗
37. Bond strength of hot-dip galvanized reinforcement in normal strength concrete structures10.1016/j.conbuildmat.2004.07.008 ↗
38. Bond strength of hot-dip galvanized hooked bars in high strength concrete structures10.1016/j.conbuildmat.2007.07.028 ↗
39. Bond strength of hot – dip galvanized reinforcement (B500B) with concrete