Finite element analysis of the behaviour of crack emanating from microvoid in cement of reconstructed acetabulum
Source abstract
Abstract
In this study, the finite element method is used to analyse the behaviour of crack emanating from microvoid and ordinary crack in cement of reconstructed acetabulum by computing the stress intensity factor at the crack tip. In order to predict the crack initiation location, the stress distribution around the microvoid is computed under three load cases. From stress results, one can note that there is a great risk of crack initiation in radial direction. From stress intensity factors computation, this same orientation is the dangerous because the mode I stress intensity factor is the higher in this direction. From comparison results on can see clearly that crack emanating from microvoid is most dangerous, and the difference in the stress intensity factors between the two cracks change with the crack inclination and this difference is constant for three load cases.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Drilling and Well Engineering · Advanced machining processes and optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (16)
Show source-provided references
1. B.P. Murphy, The Relationship Between Stress, Porosity, and Nonlinear Damage Accumulation in Acrylic Bone Cement, Department of Mechanical Engineering, Trinity College, Dublin 2, Ireland.
2. Jasty · J. Bone Joint Surg. · 1991 · 73B · 55110.1302/0301-620X.73B4.2071634 ↗
3. Lennon · Med. Eng. Physics · 2003 · 25 · 83310.1016/S1350-4533(03)00120-6 ↗
4. El'sheikh · J. Mater. Process. Technol. · 2003 · 143/144 · 24910.1016/S0924-0136(03)00352-2 ↗
5. D. Merckx, Les ciments orthopédiques dans la conception des prothèses articulaires. Biomécanique et biomatériaux, Cahiers d’enseignement de la SOFCOT, Expansion scientifique française 44 (1993) 67–76.
6. J. Tong, K.Y. Wong, Mixed Mode Fracture in Reconstructed Acetabulum, Department of Mechanical and design Engineering, University of Portsmouth, Anglesea road, Portsmouth, PO1 3 DJ, UK.
7. Christipher, Peter, Ken, Bachus, Marcis, Craig, Higginbotham, J. Arthroplasty, 16 (2001) 2.10.1054/arth.2001.28357 ↗
8. G. Bergman, J. Biomech., 26, 969–990.10.1016/0021-9290(93)90058-M ↗
9. A. Phillips, Finite Element Analysis of the Acetabulum after Impacting Grafting, The University of Edinburgh, School of civil and environmental Engineering. Crew Building, Kings Buildings, Edinburgh EH9 3JN.
10. C. Li, C. Granger, H. Del Schuttte Jr., S.B. Biggers Jr., J.M. Kennedy, R.A. Latour, Failure Analysis of Composite Femoral Components for Hip Arthroplastiy, Department of Bioengineering and Department of Mechanical Engineering, Clemson University, Clemson, SC.
11. C. Delaunay, Prothèse totale de Charnley où en est aujourd’hui le « le Gold-Standard » de l’arthoplastie primaire de hanche, Clinique de l’Yvette – 91160 longjumeau.
12. D. Poitout, Biomécanique orthopédique. Edition Masson.
13. H.K. Sorensen, Abaqus user manual.
14. S.J. Chatarina, Mechanical Behavior of a New Acrylic Radiopaque Iodine-Containing Bone Cement, Center for Biomaterials Research, University of Maastricht, P.O. Box 616, 6200 MD Maastricht, The Netherlands.
15. B.D. Ratner, A.S. Hoffman, Blomaterials Science, Bioengineering and Department of Chemical Engineering, University of Washington.
16. M.J. Yaszemski, Biomaterials in Orthopedics, Mayo Clinic, Rochester, Minnesota, U.S.A.