Count rate correction for pulse pileup in CdZnTe photon counting detectors
Source abstract
Abstract
In the practical application of CdZnTe photon counting detectors, severe detector counting distortion can be caused by pulse pileup. A count rate correction method in this paper is proposed to solve this problem. In this method, the case where multi-photons are recorded by higher energy regions due to pulse pileup crossing the energy threshold is considered to calculate the true count rates under all energy bins. A verification method based on Poisson distribution is also proposed to evaluate the accuracy of the correction method. A 16-pixel linear array CdZnTe photon counting detector was used for verification. Taking the dual-energy bin as an example, this method was introduced, and the true count rates of the high- and low-energy bins are successfully calculated. The result was highly consistent with the verification result, which proves the reliability of the proposed method.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Semiconductor Detectors and Materials · Advanced X-ray and CT Imaging · Radiation Detection and Scintillator Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (16)
Show source-provided references
1. Radiation detector materials: an overview10.1557/JMR.2008.0319 ↗
2. CdTe and CdZnTe materials for room-temperature X-ray and gamma ray detectors10.1016/S0022-0248(97)00808-7 ↗
3. Progress in the development of CdTe and CdZnTe semiconductor radiation detectors for astrophysical and medical applications10.3390/s90503491 ↗
4. Improved quality using newly designed algorithms in gamma- and X-ray fusion images with a photon counting CZT detector: combining the median modified Wiener filter and edge detection method10.1016/j.ijleo.2021.167681 ↗
5. Effect of deep-level defects on the performance of CdZnTe photon counting detectors10.3390/s20072032 ↗
6. Development of the high-pressure electro-dynamic gradient crystal-growth technology for semi-insulating CdZnTe growth for radiation detector applications10.1007/s11664-004-0076-z ↗
7. Multi-contrast CT imaging using a high energy resolution CdTe detector and a CZT photon-counting detector10.1088/1748-0221/17/01/P01004 ↗
8. Characterization of a pixelated CdTe X-ray detector using the timepix photon-counting readout chip10.1109/TNS.2012.2210909 ↗
9. The MYTHEN detector for X-ray powder diffraction experiments at the Swiss Light Source10.1107/S0909049510026051 ↗
10. The technical development of photon-counting detector CT10.1007/s00330-023-09545-9 ↗
11. Pulse pileup statistics for energy discriminating photon counting x-ray detectors10.1118/1.3592932 ↗
12. Ultra high flux 2-D CdZnTe monolithic detector Arrays for x-ray imaging applications10.1109/TNS.2007.902362 ↗
13. Prediction of pulse-height spectral distortion caused by peak pile-up effect10.1016/0029-554X(76)90623-6 ↗
14. Correction of pulse-height spectra for peak pileup effects using periodic and random pulse generators10.1016/0168-9002(87)91227-7 ↗
15. An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors10.1118/1.3429056 ↗
16. Novel technique for the study of pileup events in cryogenic bolometers10.1103/PhysRevC.104.015501 ↗