Hydrogen permeation properties of Pd-coated Pd33Ni52Si15 amorphous alloy membrane
Source abstract
Abstract
Abstract The vast majority of experimental techniques used for the measurements of hydrogen permeability through metallic membranes whose one or both surfaces are covered with a thin Pd film is based on the assumption that a ratio of film-to-membrane thickness is small enough to cause hydrogen flow to be independent of the Pd film thickness. In an attempt to verify this assumption, we have measured the hydrogen flow through the Pd33Ni52Si15 amorphous membrane covered with Pd film of 10, 20, and 30 nm in thickness. Contrary to our expectations, we have found a dramatic decrease in hydrogen flow with the increase in Pd film thickness. Our findings are discussed in terms of potential barrier between the two different phases.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Metallic Glasses and Amorphous Alloys · Electrodeposition and Electroless Coatings · Hydrogen Storage and Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Chemistry and Environmental Protection, Jan Długosz University of Częstochowa, Armii Krajowej 13/15, 42-200 Częstochowa, Poland
The Faculty of Microsystem Electronics and Photonics, Wrocław University of Technology, Janiszewskiego 11/17, 50-372 Wrocław, Poland
Institute of Physics, Jan Długosz University of Częstochowa, Armii Krajowej 13/15, 42-200 Częstochowa, Poland
References
Reference metadata was not supplied for this record.