journal article·2015-08-30

Study on antibacterial activity and cytocompatibility of Ti–6Al–4V–5Cu alloy

Z. Ma, M. Yao, R. Liu, K. Yang, L. Ren, Y. Zhang, Z. Liao, W. Liu, M. Qi

Materials Technology· Volume 30· Issue sup6
Publisher page

Abstract

A new biomedical Ti–6Al–4V–5Cu alloy with antibacterial function was developed by proper addition of copper (Cu) into Ti based alloy in this study. The microstructure, antibacterial activity and cytotoxicity of this Cu bearing titanium alloy were studied. It was found that the microstructure of Ti–6Al–4V–5Cu alloy consisted of α phase, β phase and Ti2Cu intermetallic compound, which could obtain a considerable antibacterial ability and inhibit the formation of bacterial biofilm through trace release of cupric ions from its surface. The cytotoxicity evaluation demonstrated that Ti–6Al–4V alloy played no toxic effect on the viability of MC3T3-E1 cells, showing a satisfied biocompatibility.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Materials Science and Engineering Dalian University of Technology, Dalian, China

Institute of Metal Research Chinese Academy of Sciences, Shenyang, China

Second Military Medical University Shanghai, China

Orthopedic Department Guangzhou Military General Hospital, Guangzhou, China

Institute of Medical Engineering Shenzhen Research Institute of Tsinghua University, Shenzhen, China

References (30)

Show source-provided references
1. 10.1016/0921-5093(96)10243-410.1016/0921-5093(96)10243-4 ↗
2. 10.1186/1475-925X-5-2210.1186/1475-925X-5-22 ↗
3. 10.1016/S0142-9612(00)00392-610.1016/S0142-9612(00)00392-6 ↗
4. 10.1016/S0142-9612(03)00554-410.1016/S0142-9612(03)00554-4 ↗
5. 10.1002/jbm.a.3061110.1002/jbm.a.30611 ↗
6. 10.1056/NEJMra03541510.1056/NEJMra035415 ↗
7. 10.1056/NEJM19900913323110610.1056/NEJM199009133231106 ↗
8. 10.1056/NEJMra04018110.1056/NEJMra040181 ↗
9. 10.1016/j.biomaterials.2006.11.04610.1016/j.biomaterials.2006.11.046 ↗
10. 10.1016/j.msec.2012.03.00910.1016/j.msec.2012.03.009 ↗
11. 10.1016/j.actbio.2007.11.00610.1016/j.actbio.2007.11.006 ↗
12. 10.1039/c2jm00063f10.1039/c2jm00063f ↗
13. 10.1007/s10856-008-3444-z10.1007/s10856-008-3444-z ↗
14. 10.1039/c0cp01119c10.1039/c0cp01119c ↗
15. 10.1002/jbm.b.3141210.1002/jbm.b.31412 ↗
16. 10.1016/j.msec.2013.06.01610.1016/j.msec.2013.06.016 ↗
17. 10.1016/j.jmst.2013.12.01410.1016/j.jmst.2013.12.014 ↗
18. ISO 10993-15: ‘Biological evaluation of medical devices e part 15: identification and quantification of degradation products from metals and alloys’, ANSI/AAMI, Arlington, VA, USA, 2009.
19. 10.1080/0950083080232215210.1080/09500830802322152 ↗
20. 10.1111/j.1365-2842.2004.01347.x10.1111/j.1365-2842.2004.01347.x ↗
21. 10.1016/S0109-5641(02)00080-510.1016/S0109-5641(02)00080-5 ↗
22. 10.1016/j.electacta.2009.09.01610.1016/j.electacta.2009.09.016 ↗
23. 10.1002/jbm.b.3022510.1002/jbm.b.30225 ↗
24. 10.1007/s11837-004-0145-z10.1007/s11837-004-0145-z ↗
25. 10.1016/j.matdes.2011.03.04010.1016/j.matdes.2011.03.040 ↗
26. 10.1023/A:100487350100510.1023/A:1004873501005 ↗
27. 10.1007/BF0077554310.1007/BF00775543 ↗
28. 10.1016/j.jallcom.2009.06.06610.1016/j.jallcom.2009.06.066 ↗
29. 10.1016/j.jallcom.2007.09.08410.1016/j.jallcom.2007.09.084 ↗
30. 10.1016/S0142-9612(03)00157-110.1016/S0142-9612(03)00157-1 ↗