journal article·2019-01-02

Build angle and its influence on the flexure strength of stereolithography printed hybrid resin material. An in vitro study and a fractographic analysis

Nawal Alharbi, Albert J. van de Veen, Daniel Wismeijer, Reham B. Osman

Materials Technology· Volume 34· Issue 1
Publisher page

Abstract

This study evaluated the effect of build direction on the flexure strength of stereolithography (SLA), 3D-printed hybrid composite resin material. A total of 26 bar-shaped specimens were 3D-printed using SLA-based printer. The specimens were divided into two groups based on build direction (n = 13); vertically (V), horizontally (H) printed groups. The layer thickness was 0·05 mm. Three-point bending test was performed using a universal testing machine, with a load-cell of 250 N at 1 mm min−1 crosshead speed until failure of the specimens. The fractured surfaces were analyzed using scanning electron microscopy (SEM). The mean flexure strength for (V) and (H) printed specimens was 88.2 and 90.5 MPa respectively (P > .05). Fractographic analysis revealed brittle abrupt fracture pattern for (V) group and a ductile, slow pattern with layer delamination for H-group. Though there was no statistical difference in flexure strength between the test groups, the fractographic analysis revealed that the fracture mode was different.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Additive Manufacturing and 3D Printing Technologies · Dental materials and restorations · Anatomy and Medical Technology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Oral Implantology and Prosthetic Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam , Amsterdam, The Netherlands

Prosthetic Dental Science Department, College of Dentistry, King Saud University , Riyadh, Saudi Arabia

Department of Cardiology, Vrjie Universiteit Medical Centre , Amsterdam, The Netherlands

Faculty of Dentistry, Removable Prosthodontics Department, Cairo University , Giza, Egypt

Funding

College of Dentistry, King Saud University · King Saud University

References (15)

Show source-provided references
1. 10.1007/s00170-005-2523-210.1007/s00170-005-2523-2 ↗
2. 10.1016/j.prosdent.2015.12.00210.1016/j.prosdent.2015.12.002 ↗
3. 10.11607/ijp.483510.11607/ijp.4835 ↗
4. 10.1023/B:JMSC.0000020010.73768.4a10.1023/B:JMSC.0000020010.73768.4a ↗
5. 10.11607/ijp.511710.11607/ijp.5117 ↗
6. 10.1016/j.prosdent.2016.03.01810.1016/j.prosdent.2016.03.018 ↗
7. 10.1108/1355254121125037310.1108/13552541211250373 ↗
8. Fani M · J Dent Biomater · 2015 · 2 · 73
9. Monfared M · J Dent Biomater · 2016 · 3 · 327
10. DWS · 2013
11. 10.1016/j.dental.2017.04.01310.1016/j.dental.2017.04.013 ↗
12. 10.1016/S0109-5641(02)00088-X10.1016/S0109-5641(02)00088-X ↗
13. 10.1016/0109-5641(95)80044-110.1016/0109-5641(95)80044-1 ↗
14. 10.1016/j.dental.2010.02.00810.1016/j.dental.2010.02.008 ↗
15. Greenhalgh E · 2009