journal article·2019-01-02

Wear behavior of various dental restorative materials

Muhammad Sohail Zafar

Materials Technology· Volume 34· Issue 1
Publisher page

Abstract

The aim of this study was to compare the wear behavior of various dental restorative materials and effects of wear on the surface mechanical properties. For this purpose, a multi-purpose friction/wear tester and a mechanical indenter with a diamond probe were used. The dental ceramics showed the lowest amount of wear depth (64 ± 3·2 μm) at 15 min cycle. There was an insignificant increase (p > 0·05) in the wear of ceramic in 15 min time interval, however the difference was significant (p < 0·05) while comparing at 30 min interval reaching to (99 ± 4·4 μm) at 150 min. Wear resulted in increase in the surface hardness of materials; ceramics (from 6·06 ± 1·11 GPa to 6·65 ± 1·12 GPa) and resin composites (from 1·44 ± 0·31 GPa to 1·66 ± 0·34 GPa) and significantly increase for alloys. For example, the hardness of CoCr was increased from 5·38 ± 0·72 GPa to 7·18 ± 0·75 GPa after wear. Dental ceramic remains the most wear resistant among tested materials. Among direct restorative materials, amalgam alloy has better wear resistance. Wear of dental alloys resulted in greater surface hardening compared to the direct restorative materials.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Orthopaedic implants and arthroplasty · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Restorative Dentistry, College of Dentistry, Taibah University , Al Madinah Al Munawwarah, Saudi Arabia

References (29)

Show source-provided references
1. Ten Nanci A · 2012
2. Mjör IA · 1986
3. Heintze SD · Schweiz Monatsschr Zahnmed · 2011 · 121 · 804
4. 10.1016/j.dental.2006.02.00210.1016/j.dental.2006.02.002 ↗
5. Gladwin MA · 2009
6. 10.1088/0022-3727/41/11/11300110.1088/0022-3727/41/11/113001 ↗
7. 10.1016/j.wear.2012.12.04310.1016/j.wear.2012.12.043 ↗
8. 10.1016/0109-5641(89)90090-010.1016/0109-5641(89)90090-0 ↗
9. 10.1177/002203451454421710.1177/0022034514544217 ↗
10. 10.1016/j.dental.2015.05.00410.1016/j.dental.2015.05.004 ↗
11. ISO . Dental materials–Guidance on testing of wear–Part 2: wear by two-and/or three body contact. Technical Specification; No. 2001: 14569-14572.
12. 10.4012/dmj.2014-08310.4012/dmj.2014-083 ↗
13. Sakaguchi RL · 2012
14. 10.1590/S1516-1439201200500018310.1590/S1516-14392012005000183 ↗
15. 10.2341/10-221-L10.2341/10-221-L ↗
16. Zafar MS · Life Sci J · 2014 · 11 · 11
17. 10.1016/j.dental.2006.02.00310.1016/j.dental.2006.02.003 ↗
18. 10.1016/j.dental.2006.02.00410.1016/j.dental.2006.02.004 ↗
19. 10.1016/0003-9969(70)90053-110.1016/0003-9969(70)90053-1 ↗
20. Longmore RB · 1985
21. 10.1902/jop.1976.47.6.33110.1902/jop.1976.47.6.331 ↗
22. 10.1111/j.1600-0722.1980.tb01267.x10.1111/j.1600-0722.1980.tb01267.x ↗
23. 10.1016/j.dental.2005.03.00210.1016/j.dental.2005.03.002 ↗
24. Badra VV · Oper Dent · 2005 · 30 · 213
25. Zafar MS · Technol Health Care · 2014 · 22 · 57310.3233/THC-140832 ↗
26. Yusuf ZB · J Contemp Dent Pract · 2004 · 5 · 42
27. 10.1103/PhysRevB.57.328310.1103/PhysRevB.57.3283 ↗
28. 10.1021/jp992784c10.1021/jp992784c ↗
29. 10.1016/0022-3913(71)90191-010.1016/0022-3913(71)90191-0 ↗