Fabrication of the locally reinforced open-cell nitinol stents for intracranial vascular aneurysm
Source abstract
Abstract
Intracranial vascular stent-assisted coil embolization has been widely used for intracranial vascular aneurysm. However, there are serious complication risks, such as thromboembolism, stent migration and spring coil prolapse, due to the inappropriate radial force, poor wall apposition and oversized mesh. Therefore, a locally-reinforced intracranial vascular stent was designed to improve the radial force and wall apposition performance. Based on finite element analysis and substantial measurements, the local radial force has improved 38.9% and thestability of the coil embolism has been enhanced as well. The releasing test in vitro suggests the stent can adhere to the vascular wall very well without the ‘Gator backing’ phenomenon. Furthermore, the implanting test in vivo shows complete endothelialization without restenosis and hyperplasia in 4 weeks. The outcomes of this study provide optimal design of the locally reinforced nitinol stent used for intracranial aneurysm therapy with reduced risks of vascular embolism and haemorrhagic apoplexy after implantation.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Intracranial Aneurysms: Treatment and Complications · Cerebrovascular and Carotid Artery Diseases · Moyamoya disease diagnosis and treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Shi-changxu Innovation Center for Advanced Materials, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, Liaoning, China
School of Materials Science and Engineering, University of Science and Technology of China, Hefei, Anhui, China
School of Materials Science and Engineering, Shenyang University of Technology, Shenyang, Liaoning, China
School and Hospital of Stomatology, China Medical University, Shenyang, Liaoning, China
Funding
National Key Research and Development Program of China
References (32)
Show source-provided references
1. 10.1016/S0140-6736(16)30668-710.1016/S0140-6736(16)30668-7 ↗
2. 10.1080/10667857.2022.206562110.1080/10667857.2022.2065621 ↗
3. 10.1080/10667857.2016.122514810.1080/10667857.2016.1225148 ↗
4. 10.1080/10667857.2019.159172610.1080/10667857.2019.1591726 ↗
5. 10.1016/j.jocn.2016.01.03510.1016/j.jocn.2016.01.035 ↗
6. 10.3171/2011.4.JNS10205010.3171/2011.4.JNS102050 ↗
7. 10.3174/ajnr.A258410.3174/ajnr.A2584 ↗
8. Ebrahimi N, Claus B, Lee CY, et al. Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: an in vitro study. Am J Neuroradiol. 2007;28(5):823–829.
9. 10.2214/AJR.12.895410.2214/AJR.12.8954 ↗
10. 10.1136/jnis.2010.00244410.1136/jnis.2010.002444 ↗
11. 10.4103/ajns.AJNS_284_1910.4103/ajns.AJNS_284_19 ↗
12. 10.12659/PJR.89681810.12659/PJR.896818 ↗
13. 10.1007/s12573-011-0044-110.1007/s12573-011-0044-1 ↗
14. 10.1016/j.actbio.2022.01.04510.1016/j.actbio.2022.01.045 ↗
15. 10.1007/s13239-017-0295-010.1007/s13239-017-0295-0 ↗
16. 10.1055/s-0031-127168110.1055/s-0031-1271681 ↗
17. 10.5469/neuroint.2017.12.1.3110.5469/neuroint.2017.12.1.31 ↗
18. 10.1038/srep0363010.1038/srep03630 ↗
19. 10.1016/S0002-8703(97)70178-910.1016/S0002-8703(97)70178-9 ↗
20. 10.1002/jbm.a.3502510.1002/jbm.a.35025 ↗
21. 10.1039/b807129b10.1039/b807129b ↗
22. 10.1227/01.NEU.0000372094.75062.D410.1227/01.NEU.0000372094.75062.D4 ↗
23. 10.3174/ajnr.A122410.3174/ajnr.A1224 ↗
24. 10.1227/01.NEU.0000343745.18753.D610.1227/01.NEU.0000343745.18753.D6 ↗
25. 10.1227/NEU.0b013e3182242bfd10.1227/NEU.0b013e3182242bfd ↗
26. 10.1016/j.surneu.2005.05.01910.1016/j.surneu.2005.05.019 ↗
27. Broadbent LP, Moran CJ, Cross DT, et al. Management of neuroform stent dislodgement and misplacement. Am J Neuroradiol. 2003;24(9):1819–1822.
28. 10.1016/j.jmbbm.2012.02.00610.1016/j.jmbbm.2012.02.006 ↗
29. 10.1111/aor.1200110.1111/aor.12001 ↗
30. 10.1016/j.carrev.2009.04.00510.1016/j.carrev.2009.04.005 ↗
31. 10.1007/s40195-022-01435-110.1007/s40195-022-01435-1 ↗
32. 10.1088/0964-1726/22/8/08400810.1088/0964-1726/22/8/084008 ↗