Corrosion and in vitro mechanical behaviour of additively manufactured 316L stainless steel for biomedical application
Source abstract
Abstract
Laser-metal deposition (LMD) is a cutting-edge additive-manufacturing technique for fabricating bio-implants. This study systematically examines the influence of microstructural evolution in as-built and solution-treated LMD-fabricated 316L stainless-steel on corrosion behaviour and mechanical performance. Although microstructural differences are observed between the top and bottom sections of the as-built specimen, solution-annealing homogenizes the structure. Superior corrosion resistance and surface-film hardness are noted for solution-treated specimens immersed in Ringer’s-Lactate solution for 1 to 30 days. Mechanical performance is assessed through in vitro tensile and strain-controlled fatigue tests while specimens were immersed in Ringer’s-Lactate solution at 37 °C. These experiments simulate a critical loading condition that an implant typically experiences in a biological atmosphere. Interestingly, the solutionized alloy shows superior ductility and fatigue resistance in a biomedical environment, at the expense of strength. The study highlights as-built LMD-316L stainless-steel for high-strength applications, whereas the solutionized version is vital for prolonged service under repeated loading.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Additive Manufacturing Materials and Processes · Titanium Alloys Microstructure and Properties · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Metallurgical and Materials Engineering, Indian Institute of Technology
Department of Metallurgical and Materials Engineering, National Institute of Technology
Funding
Indian Institute of Technology Kharagpur
References (100+)
Show source-provided references
1. 10.1098/rsif.2008.015110.1098/rsif.2008.0151 ↗
2. 10.1016/S0010-938X(03)00148-310.1016/S0010-938X(03)00148-3 ↗
3. 10.1016/j.bioactmat.2021.12.02710.1016/j.bioactmat.2021.12.027 ↗
4. 10.1002/adma.20190199410.1002/adma.201901994 ↗
5. 10.1016/j.addma.2018.05.03210.1016/j.addma.2018.05.032 ↗
6. 10.1016/j.bioactmat.2021.12.02710.1016/j.bioactmat.2021.12.027 ↗
7. 10.1016/j.powtec.2017.12.05810.1016/j.powtec.2017.12.058 ↗
8. 10.1007/s11665-021-06069-510.1007/s11665-021-06069-5 ↗
9. 10.5301/jabfm.500037110.5301/jabfm.5000371 ↗
10. 10.1016/j.jmapro.2021.02.02210.1016/j.jmapro.2021.02.022 ↗
11. 10.1016/B978-0-12-816137-1.00040-410.1016/B978-0-12-816137-1.00040-4 ↗
12. 10.1080/2374068X.2020.173123610.1080/2374068X.2020.1731236 ↗
13. 10.1007/978-3-319-89542-0_210.1007/978-3-319-89542-0_2 ↗
14. 10.3390/ma1203040710.3390/ma12030407 ↗
15. 10.1016/j.addma.2019.02.00510.1016/j.addma.2019.02.005 ↗
16. 10.1080/21663831.2019.167820210.1080/21663831.2019.1678202 ↗
17. 10.1016/j.ijfatigue.2018.12.02910.1016/j.ijfatigue.2018.12.029 ↗
18. 10.1016/j.msea.2019.13826810.1016/j.msea.2019.138268 ↗
19. 10.1016/j.ijfatigue.2017.01.00110.1016/j.ijfatigue.2017.01.001 ↗
20. 10.1016/j.pmatsci.2024.10127710.1016/j.pmatsci.2024.101277 ↗
21. 10.1016/j.matpr.2023.07.10910.1016/j.matpr.2023.07.109 ↗
22. 10.1016/j.actamat.2020.08.03310.1016/j.actamat.2020.08.033 ↗
23. 10.1111/ffe.1368410.1111/ffe.13684 ↗
24. 10.3390/met1506065010.3390/met15060650 ↗
25. 10.1016/j.engfracmech.2014.03.00810.1016/j.engfracmech.2014.03.008 ↗
26. 10.1016/j.ijfatigue.2023.10766610.1016/j.ijfatigue.2023.107666 ↗
27. 10.3390/met1107104610.3390/met11071046 ↗
28. 10.1007/s11837-016-1822-410.1007/s11837-016-1822-4 ↗
29. 10.1016/j.corsci.2022.11083010.1016/j.corsci.2022.110830 ↗
30. 10.1016/j.matchar.2020.11020410.1016/j.matchar.2020.110204 ↗
31. 10.1007/s12540-020-00838-y10.1007/s12540-020-00838-y ↗
32. 10.1016/j.electacta.2018.04.18810.1016/j.electacta.2018.04.188 ↗
33. 10.1149/1945-7111/abc10e10.1149/1945-7111/abc10e ↗
34. 10.1007/s42452-020-03530-310.1007/s42452-020-03530-3 ↗
35. 10.1016/j.corsci.2020.10891410.1016/j.corsci.2020.108914 ↗
36. 10.1016/j.optlastec.2018.07.05110.1016/j.optlastec.2018.07.051 ↗
37. 10.1016/j.jmst.2019.09.01710.1016/j.jmst.2019.09.017 ↗
38. 10.1016/j.ijfatigue.2024.10827010.1016/j.ijfatigue.2024.108270 ↗
39. 10.1016/j.ijfatigue.2024.10814310.1016/j.ijfatigue.2024.108143 ↗
40. 10.1007/s40964-021-00164-810.1007/s40964-021-00164-8 ↗
41. 10.1016/j.engfracmech.2022.10888310.1016/j.engfracmech.2022.108883 ↗
42. 10.1016/S0142-1123(03)00080-X10.1016/S0142-1123(03)00080-X ↗
43. 10.1007/s11665-021-06101-810.1007/s11665-021-06101-8 ↗
44. 10.1016/j.msea.2015.07.05610.1016/j.msea.2015.07.056 ↗
45. 10.1016/j.msea.2017.10.00210.1016/j.msea.2017.10.002 ↗
46. 10.1016/j.pmatsci.2022.10105110.1016/j.pmatsci.2022.101051 ↗
47. E3-95 A. Standard practice for preparation of metallographic specimens. Annu B ASTM Stand Vol. 1995;3:1–8.
48. Standard test method for conducting cyclic potentiodynamic polarization measurements to determine the corrosion susceptibility of small implant devices. Methods ASF-4. 1. on MT. ASTM International; 2019
49. 10.1557/JMR.1992.156410.1557/JMR.1992.1564 ↗
50. 10.1007/s11661-018-4956-x10.1007/s11661-018-4956-x ↗
51. Drews A. Standard Test Method for. Man Hydrocarb Anal 6th Ed. 2008;545-545–3.10.1520/MNL10913M ↗
52. 10.1016/j.matdes.2013.10.01610.1016/j.matdes.2013.10.016 ↗
53. 10.1016/j.mtla.2019.10035910.1016/j.mtla.2019.100359 ↗
54. 10.1007/s10853-020-05109-010.1007/s10853-020-05109-0 ↗
55. 10.1016/j.msea.2017.12.05810.1016/j.msea.2017.12.058 ↗
56. 10.1016/j.pmatsci.2017.10.00110.1016/j.pmatsci.2017.10.001 ↗
57. 10.1007/s11665-014-0958-z10.1007/s11665-014-0958-z ↗
58. 10.1016/j.addma.2014.10.00310.1016/j.addma.2014.10.003 ↗
59. 10.1016/j.msea.2023.14502110.1016/j.msea.2023.145021 ↗
60. 10.1016/j.addma.2018.05.01410.1016/j.addma.2018.05.014 ↗
61. 10.1016/j.jmst.2019.03.00310.1016/j.jmst.2019.03.003 ↗
62. 10.1016/j.electacta.2010.09.02310.1016/j.electacta.2010.09.023 ↗
63. 10.1016/j.jmatprotec.2014.06.00210.1016/j.jmatprotec.2014.06.002 ↗
64. 10.1016/j.matdes.2012.03.01110.1016/j.matdes.2012.03.011 ↗
65. 10.1007/s11665-013-0784-810.1007/s11665-013-0784-8 ↗
66. 10.1016/j.corsci.2022.11077710.1016/j.corsci.2022.110777 ↗
67. 10.3390/met1102018210.3390/met11020182 ↗
68. 10.1016/j.corsci.2010.07.00410.1016/j.corsci.2010.07.004 ↗
69. 10.1016/j.apsusc.2018.10.15010.1016/j.apsusc.2018.10.150 ↗
70. 10.1007/s11665-021-05571-010.1007/s11665-021-05571-0 ↗
71. 10.1007/s12540-022-01342-110.1007/s12540-022-01342-1 ↗
72. 10.1021/ie403935710.1021/ie4039357 ↗
73. 10.1016/j.apsusc.2013.11.11010.1016/j.apsusc.2013.11.110 ↗
74. 10.1155/2013/49782310.1155/2013/497823 ↗
75. 10.1016/j.corsci.2008.10.04010.1016/j.corsci.2008.10.040 ↗
76. 10.1016/j.corsci.2020.10866610.1016/j.corsci.2020.108666 ↗
77. 10.1016/j.mtla.2018.06.01510.1016/j.mtla.2018.06.015 ↗
78. 10.1016/j.jallcom.2017.06.31010.1016/j.jallcom.2017.06.310 ↗
79. 10.1016/j.addma.2019.10101310.1016/j.addma.2019.101013 ↗
80. 10.1002/adem.20210169910.1002/adem.202101699 ↗
81. 10.1039/C4RA16721J10.1039/C4RA16721J ↗
82. 10.1016/j.scriptamat.2018.06.01110.1016/j.scriptamat.2018.06.011 ↗
83. 10.1016/j.corsci.2023.11181410.1016/j.corsci.2023.111814 ↗
84. 10.1016/j.jallcom.2017.01.19610.1016/j.jallcom.2017.01.196 ↗
85. 10.1016/j.electacta.2009.10.02610.1016/j.electacta.2009.10.026 ↗
86. 10.1149/1.205933810.1149/1.2059338 ↗
87. 10.1557/S088376940004163410.1557/S0883769400041634 ↗
88. 10.1016/j.corsci.2014.11.04110.1016/j.corsci.2014.11.041 ↗
89. 10.1016/j.elecom.2018.02.00110.1016/j.elecom.2018.02.001 ↗
90. Ligabo IA Braga V Ferreira CCA et al. Microstructure and corrosion behavior of AISI 316 steel layers deposited on AISI 347 steel substrate by laser metal deposition. 2022;1–19.10.3390/met12122161 ↗
91. 10.1016/j.corsci.2021.10995110.1016/j.corsci.2021.109951 ↗
92. 10.3184/096034011X1318268557979510.3184/096034011X13182685579795 ↗
93. 10.1016/S0010-938X(02)00054-910.1016/S0010-938X(02)00054-9 ↗
94. 10.1016/j.ijplas.2019.05.00910.1016/j.ijplas.2019.05.009 ↗
95. 10.1016/j.matdes.2016.09.04310.1016/j.matdes.2016.09.043 ↗
96. 10.1016/j.ijfatigue.2021.10622610.1016/j.ijfatigue.2021.106226 ↗
97. 10.3390/ma1601006510.3390/ma16010065 ↗
98. 10.1111/ffe.1384510.1111/ffe.13845 ↗
99. 10.1016/j.ijfatigue.2003.12.00210.1016/j.ijfatigue.2003.12.002 ↗
100. 10.1016/j.engfracmech.2017.03.00610.1016/j.engfracmech.2017.03.006 ↗