Fabrication of biodegradable MgXCu(X=0, 0.1, 0.4, 0.7) coating on Ti6Al4V alloy with enhanced antibacterial property
Source abstract
Abstract
Currently, orthopaedic implant materials such as titanium alloy are biologically inert materials which are not easily integrated with bone tissues, thus resulting in implantation failures due to the loosening and infection. In this study, bioactive MgXCu(X = 0, 0.1, 0.4, 0.7) coatings were successfully fabricated on Ti6Al4 V substrate by arc ion plating (AIP) technique to improve the antibacterial property. The surface composition and morphology of the coating was characterised by X-ray diffraction, inductively coupled plasma-atomic emission spectrometry (ICP) and scanning electron microscope (SEM) equipped with energy dispersive spectroscopy (EDS). The electrochemical experiment and immersion test showed the corrosion rate of MgXCu coating increased with the addition of Cu element. Antibacterial assays proved that the MgXCu coating could successfully reduce the viability of Staphylococcus aureus (S.aureus) and the thickness of the bacterial film. Consequently, it is concluded that MgXCu coated Ti6Al4 V with antibacterial property is much potential to be used in orthopaedic applications.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Metal and Thin Film Mechanics · MXene and MAX Phase Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Metal Research, Chinese Academy of Science, Shenyang, China
School of Materials Science and Engineering, University of Science and Technology of China, Shenyang, China
Jiangsu Key Laboratory of Materials Surface Science and Technology, Changzhou University, Changzhou, China
Department of Metallurgical, Material and Biomedical Engineering, The University of Texas at EI Paso, El Paso, TX, USA
Funding
National Natural Science Foundation of China
References (33)
Show source-provided references
1. 10.1038/srep4075510.1038/srep40755 ↗
2. 10.1371/journal.pone.007928910.1371/journal.pone.0079289 ↗
3. 10.3171/2014.9.SPINE13117610.3171/2014.9.SPINE131176 ↗
4. 10.3171/2013.7.SPINE135910.3171/2013.7.SPINE1359 ↗
5. 10.3233/THC-15091210.3233/THC-150912 ↗
6. 10.1016/j.actbio.2007.05.00910.1016/j.actbio.2007.05.009 ↗
7. 10.1016/j.biomaterials.2009.09.06310.1016/j.biomaterials.2009.09.063 ↗
8. 10.1002/jbm.a.3457510.1002/jbm.a.34575 ↗
9. 10.1111/j.1532-849X.2012.00835.x10.1111/j.1532-849X.2012.00835.x ↗
10. 10.1016/j.biomaterials.2008.12.00110.1016/j.biomaterials.2008.12.001 ↗
11. 10.1016/j.jallcom.2015.04.20710.1016/j.jallcom.2015.04.207 ↗
12. 10.1007/s00402-013-1785-710.1007/s00402-013-1785-7 ↗
13. 10.1080/10667857.2016.123979810.1080/10667857.2016.1239798 ↗
14. 10.1016/j.biomaterials.2005.10.00310.1016/j.biomaterials.2005.10.003 ↗
15. 10.1002/jbm.a.3326710.1002/jbm.a.33267 ↗
16. 10.1016/j.mser.2014.01.00110.1016/j.mser.2014.01.001 ↗
17. 10.1080/10667857.2016.121355010.1080/10667857.2016.1213550 ↗
18. 10.1080/10667857.2016.122205310.1080/10667857.2016.1222053 ↗
19. 10.1016/j.actamat.2004.06.01910.1016/j.actamat.2004.06.019 ↗
20. 10.1002/jbm.b.3383910.1002/jbm.b.33839 ↗
21. 10.1038/srep2737410.1038/srep27374 ↗
22. 10.1021/acsami.8b1403810.1021/acsami.8b14038 ↗
23. 10.1016/j.matlet.2018.08.06310.1016/j.matlet.2018.08.063 ↗
24. 10.1016/j.matdes.2016.01.13510.1016/j.matdes.2016.01.135 ↗
25. 10.1038/srep2998510.1038/srep29985 ↗
26. 10.1016/j.matlet.2011.07.10910.1016/j.matlet.2011.07.109 ↗
27. 10.1038/srep4075510.1038/srep40755 ↗
28. 10.1590/0103-644020160016110.1590/0103-6440201600161 ↗
29. 10.1002/jbm.b.3311310.1002/jbm.b.33113 ↗
30. 10.1063/1.145961910.1063/1.1459619 ↗
31. 10.1016/j.biomaterials.2016.08.03110.1016/j.biomaterials.2016.08.031 ↗
32. 10.1080/10667857.2018.143217010.1080/10667857.2018.1432170 ↗
33. 10.1038/srep2737410.1038/srep27374 ↗