Preparation and performance of a solid-state thin-film Ag/AgCl quasi-reference electrode modified by chitosan-graphene
Source abstract
Abstract
Ag/AgCl reference electrode is widely used in electrochemical and photoelectrochemical measurement. In this paper, we developed a solid-state thin film Ag/AgCl quasi-reference electrode modified by chitosan-graphene. The quasi-reference electrode consisted of Ag layer (deposited by magnetron sputtering), AgCl layer (chloridized by NaClO solution), and modification membrane. The performance of a bared Ag/AgCl electrode, an Ag/AgCl electrode modified by chitosan, graphene, and by chitosan-graphene respectively was investigated. Surface morphology, energy spectrum, and electrochemical experiments were conducted in four Ag/AgCl electrodes with different modifications, respectively. With the surface morphology and energy spectrum analysis, the thickness of Ag layer and the conversion of Ag to AgCl were verified firstly. Then the durability, reversibility, and CV behavior were tested in different solutions. The results demonstrated excellent features of the Ag/AgCl quasi-reference electrode modified by chitosan-graphene in all measurements. The developed quasi-reference electrode can be applied in pH measurement, electrochemical tests, and photoelectrochemical test.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Analytical Chemistry and Sensors · Conducting polymers and applications · Electrochemical Analysis and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Electrical Engineering, Henan University of Technology, Zhengzhou, China
School of Mechanical Engineering, Jiangsu University, Zhenjiang, China
School of Art and Design, Henan University of Technology, Zhengzhou, China
Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta, Canada
Funding
Key Research Project of Henan Educational Committee of China · Open Project of Jiangsu Key Laboratory of Advanced Food Manufacturing Equipment & Technology
References (30)
Show source-provided references
1. 10.1016/j.electacta.2012.03.16410.1016/j.electacta.2012.03.164 ↗
2. 10.1021/ja310354910.1021/ja3103549 ↗
3. 10.1108/0260228121120940010.1108/02602281211209400 ↗
4. 10.1007/s13344-015-0065-410.1007/s13344-015-0065-4 ↗
5. 10.1021/ie202602510.1021/ie2026025 ↗
6. 10.1016/j.electacta.2011.01.08010.1016/j.electacta.2011.01.080 ↗
7. 10.1021/acsnano.8b0221910.1021/acsnano.8b02219 ↗
8. 10.3390/s15081810210.3390/s150818102 ↗
9. 10.1039/C3LC51029H10.1039/C3LC51029H ↗
10. 10.1016/j.snb.2014.07.06710.1016/j.snb.2014.07.067 ↗
11. 10.1016/j.snb.2013.02.08810.1016/j.snb.2013.02.088 ↗
12. 10.3390/s13030363510.3390/s130303635 ↗
13. 10.1021/ac070820v10.1021/ac070820v ↗
14. 10.3390/s15030646910.3390/s150306469 ↗
15. 10.1016/j.snb.2005.10.01810.1016/j.snb.2005.10.018 ↗
16. 10.1002/aenm.20190109610.1002/aenm.201901096 ↗
17. Wang N · Electroanalysis · 2019 · 31 · 56010.1002/elan.201800532 ↗
18. 10.1016/j.apsusc.2015.11.17910.1016/j.apsusc.2015.11.179 ↗
19. 10.1039/c3ra41869c10.1039/c3ra41869c ↗
20. Mohammad-Rezaei R · Electroanalysis · 2012 · 24 · 209410.1002/elan.201200286 ↗
21. 10.1016/j.bios.2013.06.05510.1016/j.bios.2013.06.055 ↗
22. 10.1142/S179360471540004410.1142/S1793604715400044 ↗
23. 10.1016/j.nanoen.2018.03.03610.1016/j.nanoen.2018.03.036 ↗
24. 10.1016/j.ab.2015.07.00110.1016/j.ab.2015.07.001 ↗
25. 10.1007/s00604-013-0977-810.1007/s00604-013-0977-8 ↗
26. 10.1016/j.bios.2014.04.03510.1016/j.bios.2014.04.035 ↗
27. 10.1142/S179360471650045410.1142/S1793604716500454 ↗
28. 10.1016/S0040-6090(01)01783-710.1016/S0040-6090(01)01783-7 ↗
29. 10.1021/nl061702a10.1021/nl061702a ↗
30. 10.1088/1361-6501/aa54f810.1088/1361-6501/aa54f8 ↗