Effects of design parameters andAftemperature on superelastic behaviour of Nitinol stent for application in biliary duct: finite element analysis
Source abstract
Abstract
For more than a decade, stent implantation has been strategically used for solving gastrointestinal dilemmas such as biliary stenosis. Predicaments like insufficient radial strength, low twisting ability, inappropriate dynamic behaviour and restenosis are expected to be solved by the introduction of new designs. Superelastic Nitinol stent is an interesting alternative for minimising these tight spots. The application of finite element method to predict metallurgical and geometric behaviour of superelastic Nitinol stents for biliary duct dilatation is supported by conventional crimp tests. Model calculations show that all stents encounter the highest stress in their intersegment curvature. Inner curvature can, thus, be considered as the most critical segment with the highest frequency of martensite assessment. Owing to lower chronic outward force, higher radial resistive force and more suitable superelastic behaviour, Nitinol stents with optimal Af temperature of 24°C and intersegment angle of 65° are shown to have the best mechanical performance for clinical applications. Moreover, model calculations show that a 1° change in stent intersegment and 2°C change in Af temperature can substantially influence the mechanical performance of the stent.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Shape Memory Alloy Transformations · Magnesium Alloys: Properties and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (52)
Show source-provided references
1. Ganji A. · Middle East J. Digest. Dis. · 2009 · 1 · 56
2. 10.1016/S0160-791X(01)00005-710.1016/S0160-791X(01)00005-7 ↗
3. 10.1016/j.gie.2008.09.03210.1016/j.gie.2008.09.032 ↗
4. Baron T. H. · Am. Soc. Gastrointest. Endosc. · 2009 · 17 · 1
5. 10.1007/s00330-003-2022-510.1007/s00330-003-2022-5 ↗
6. 10.1080/1364570000916965410.1080/13645700009169654 ↗
7. Patrick B. · Invest. Radiol. · 2001 · 36 · 52110.1097/00004424-200109000-00004 ↗
8. 10.1016/S0045-7949(97)00014-X10.1016/S0045-7949(97)00014-X ↗
9. 10.1115/1.193420310.1115/1.1934203 ↗
10. 10.1016/j.jbiomech.2008.05.03210.1016/j.jbiomech.2008.05.032 ↗
11. 10.1016/j.jbiomech.2008.01.01610.1016/j.jbiomech.2008.01.016 ↗
12. 10.1016/j.medengphy.2008.11.00810.1016/j.medengphy.2008.11.008 ↗
13. Silber G. · Int. J. Energy Technol. · 2010 · 2 · 1
14. 10.1016/S1359-6454(97)00144-410.1016/S1359-6454(97)00144-4 ↗
15. 10.3109/1364570000906305710.3109/13645700009063057 ↗
16. Koop K. · Progr. Biomed. Res. · 2001 · 6 · 237
17. 10.1080/1364570041001723610.1080/13645700410017236 ↗
18. 10.1016/j.matchar.2007.02.00710.1016/j.matchar.2007.02.007 ↗
19. 10.1016/j.jmbbm.2010.10.00410.1016/j.jmbbm.2010.10.004 ↗
20. Migliavacca F. · Biomech. Model. Mechanobiol. · 2004 · 2 · 20510.1007/s10237-004-0039-6 ↗
21. 10.1016/j.jbiomech.2005.09.01810.1016/j.jbiomech.2005.09.018 ↗
22. 10.1016/j.medengphy.2010.10.01110.1016/j.medengphy.2010.10.011 ↗
23. 10.1016/S0045-7825(96)01147-410.1016/S0045-7825(96)01147-4 ↗
24. 10.1007/s11665-009-9408-810.1007/s11665-009-9408-8 ↗
25. Rebelo N. · Abaqus User’s Conf. · 2001 · 143 · 421
26. 10.1016/S0045-7825(96)01147-410.1016/S0045-7825(96)01147-4 ↗
27. 10.1016/0020-7683(95)00082-810.1016/0020-7683(95)00082-8 ↗
28. 10.1007/s11665-009-9409-710.1007/s11665-009-9409-7 ↗
29. 10.1016/j.ijplas.2009.12.00310.1016/j.ijplas.2009.12.003 ↗
30. 10.1016/S1359-6454(01)00385-810.1016/S1359-6454(01)00385-8 ↗
31. 10.1179/02670830322500194810.1179/026708303225001948 ↗
32. 10.4028/www.scientific.net/AMM.3-4.4710.4028/www.scientific.net/AMM.3-4.47 ↗
33. 10.1243/03093247JSA19510.1243/03093247JSA195 ↗
34. 10.1520/JAI10038810.1520/JAI100388 ↗
35. 10.1111/j.1475-1305.2008.00414.x10.1111/j.1475-1305.2008.00414.x ↗
36. Belytschko T., Liu W. K. and Moran B. ‘Nonlinear finite elements for continua and structures’; 2000, New York, Wiley.
37. Auricchio F. · CMES · 2010 · 57 · 225
38. A. Farnoush, Q. Li: ‘Three Dimensional Nonlinear Finite Element Analysis of the Newly Designed Cardiovascular Stent’, 5thAustralasian Congress on Applied Mechanics (ACAM), Brisbane, Australia, December 2007, 10–12.
39. 10.1016/j.jbiomech.2007.02.02410.1016/j.jbiomech.2007.02.024 ↗
40. X. Gong, T. Duerig, A. R. Pelton, N. Rebelo, K. Perry: ‘Finite element analysis and experimental evaluation of superelastic Nitinol stents’, In Proceedings of the International Conference on Shape Memory and Superelastic Technology (SMST), Monterey, CA, USA, 2003, 1–11.
41. 10.1115/1.193420310.1115/1.1934203 ↗
42. Salaheldin M. · Cardiovasc. Eng. Technol. · 2010 · 1 · 26910.1007/s13239-010-0023-5 ↗
43. Gideon V. · Trends Biomater. Artif. Organs · 2009 · 23 · 16
44. 10.1016/j.msea.2003.10.32610.1016/j.msea.2003.10.326 ↗
45. 10.1016/j.jmbbm.2007.08.00110.1016/j.jmbbm.2007.08.001 ↗
46. M. Santillo: ‘Master’s dissertation, Fracture and crack propagation study of a Superficial Femoral Artery Nitinol stent’, Pavia University, Lombardy, Italy, 2008.
47. 10.1115/1.178265010.1115/1.1782650 ↗
48. 10.1115/1.178291210.1115/1.1782912 ↗
49. Canic S. · Tex Heart Inst. J. · 2005 · 32 · 502
50. 10.1557/mrs2002.4310.1557/mrs2002.43 ↗
51. 10.1016/j.msea.2003.10.33510.1016/j.msea.2003.10.335 ↗
52. M. Patel, D. Plumley and R. Bouthot: ‘The Effects of Varying Active AfTemperatures on the Fatigue Properties of Nitinol Wire’, ASM Material and Process Conference and For Medical Devices Exposition (MPMD), Boston, MA, USA, November 2005, 1–8.