journal article·2021-05-12

Wear and validation of posterior stabilized knee prosthesis with the knee simulator

Erkan Bahçe, Ender Emir

Materials Technology· Volume 36· Issue 6
Publisher page

Abstract

Today, the use of posterior stabilized implants has begun to become widely. Therefore, it is important to compare this type of prosthesis with existing knee prosthesis. In this study, the wear and validation of the posterior stabilized total knee prosthesis with knee simulator was evaluated. The test was carried out to determine the validation of the used total knee prosthesis. Size 3 posterior stabilized total knee joint prosthesis were used as validation test samples. When the images obtained were examined, the types of wear occurring in knee prosthesis were encountered in the literature. In addition, the results showed that the efficiency of the posterior stabilized total knee prosthesis was higher.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Knee injuries and reconstruction techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering, Inonu University, Malatya, Turkey

Funding

OTIMED Medical Company and Inonu University BAP

References (19)

Show source-provided references
1. 10.5312/wjo.v5.i4.46010.5312/wjo.v5.i4.460 ↗
2. 10.1016/j.arth.2013.04.05110.1016/j.arth.2013.04.051 ↗
3. 10.1016/j.clinbiomech.2013.11.00710.1016/j.clinbiomech.2013.11.007 ↗
4. 10.1016/j.jbiomech.2015.09.00710.1016/j.jbiomech.2015.09.007 ↗
5. 10.1016/j.jbiomech.2015.06.00710.1016/j.jbiomech.2015.06.007 ↗
6. Romeo A. Design and development of a knee simulator device. PhD Thesis. Politecnico Di Torino University Belgium; 2015.
7. Campbell N. Design of knee simulator for the testing of total knee prosthesis. PhD Thesis. Cape Town University South Africa; 2008.
8. 10.1115/1.402450610.1115/1.4024506 ↗
9. 10.1016/j.wear.2009.01.02810.1016/j.wear.2009.01.028 ↗
10. 10.1016/S0021-9290(00)00094-410.1016/S0021-9290(00)00094-4 ↗
11. 10.1016/j.wear.2007.01.12010.1016/j.wear.2007.01.120 ↗
12. 10.1016/j.wear.2008.02.02410.1016/j.wear.2008.02.024 ↗
13. De Jongh. D Control of knee flexion aim a knee simulator. PhD Thesis. Gent University Belgium; 2013.
14. ISO. Loading and displacement parameters for wear-testing machines with displacemet control and corresponding environmental conditions for test. ISO 14243-3. International Organization for Standardization; 2014.
15. Shı J. Finite element analysis of total knee replacement considering gait cycle load and malalıgnment. PhD Thesis. Wolverhampton University England; 2007.
16. Bahce E · Ordu Univ J Sci Technol · 2018 · 8 · 187
17. 10.1016/j.jmbbm.2018.07.01110.1016/j.jmbbm.2018.07.011 ↗
18. 10.1007/s12178-014-9218-y10.1007/s12178-014-9218-y ↗
19. 10.1016/j.powtec.2010.01.01610.1016/j.powtec.2010.01.016 ↗