journal article·2014-11-17

Improved Stress Shielding of a Coated Cemented Hip Stem by Functionally Graded Materials

Hassan S. Hedia, Noha Fouda

Materials Testing· Volume 56· Issue 11-12
Publisher page

Abstract

Abstract Surfaces are the primary contact zones between a biomaterial and its host organism. Surface treatment or coating provides a means to fulfill demanding structural and mechanical requirements of the prostheses. As well as, a number of studies have been performed on functionally graded materials (FGM) and their suitability for use as the biomaterial of choice in various prostheses. This study investigates the effect of utilizing the two concepts of FGM and coating, in designing new hip stem material. The results of this study concluded that the optimal FGM cemented stem is consisting of titanium at the upper stem layers graded to collagen at lower stem layers. The optimal functionally graded stem coated with collagen reduced the stress shielding by 51% compared to homogenous titanium stem coated with collagen. However, this optimal graded stem coated with hydroxyapatite showed a reduction of stress shielding by 57% compared to homogenous titanium stem coated with hydroxyapatite.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

King Abdulaziz University , Jeddah , Kingdom of Saudi Arabia

Mansoura , Egypt

References (31)

Show source-provided references
1. Is hydroxyapatite coating necessary to improve survivorship of porous-coated titanium femoral stem?10.1016/j.arth.2011.06.020 ↗
2. In vivo behaviour of hydroxyapatite coatings on titanium implants: A quantitative study in the rabbit10.1016/S0142-9612(01)00392-1 ↗
3. The addition of a hydroxyapatite coating changes the immediate postoperative stability of a plasma-sprayed femoral stem10.1016/j.arth.2010.02.004 ↗
4. Histomorphometric study of bone reactions with different hydroxyapatite coating thickness on dental implants in dogs10.1016/j.tsf.2011.01.004 ↗
5. The effect of substrate roughness and hydroxyapatite coating thickness on implant shear strength10.1054/arth.2002.30410 ↗
6. Effect of collagen on the mechanical properties of hydro-xyapatite coatings10.1016/j.jmbbm.2011.02.001 ↗
7. Evaluation of interfacial shear strength and residual stress of sol–gel derived fluoridated hydroxyapatite coatings on Ti6Al4V substrates10.1016/j.engfracmech.2006.04.021 ↗
8. Adhesion strength of sol-gel derived fluoridated hydroxyapatite coatings10.1016/j.surfcoat.2005.11.033 ↗
9. Synthesis and corrosion of functionally gradient TiO2 and hydroxyapatite coatings on Ti-6Al-4V10.1016/j.matchemphys.2007.06.026 ↗
10. Novel hydroxyapatite coating on new porous titanium and titanium-HDPE composite for hip implant10.1016/j.surfcoat.2007.10.040 ↗
11. A method of material optimization of cementless stem through functionally graded material10.1007/s10999-005-3307-4 ↗
12. A new design of a cementless hip stem using one and two-dimensional functionally graded materials
13. Design of functionally graded dental implant in the presence of cancellous bone10.1002/jbm.b.30275 ↗
14. A three-dimensional finite element study on the biomechanical behavior of an FGBM dental implant in surrounding bone10.1016/j.jbiomech.2006.11.019 ↗
15. Shape optimization of a Charnley prosthesis based on the fatigue notch factor10.3233/BME-1996-6307 ↗
16. Effect of FE idealization
17. 1996
18. Finite element analysis and experimental investigation of stresses in femur with hip endoprosthesis10.1016/0021-9290(83)90082-9 ↗
19. Shear properties of bilaminar polymethylmethcrylate cement mantles in revision hip joint arthroplasty10.1016/j.arth.2006.04.010 ↗
20. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
21. Mathematical optimization of elastic properties: Application to cementless hip stem design10.1115/1.2796076 ↗
22. Three-dimensional shape reconstruction and finite element analysis of femur before and after the cementless type of total hip replacement10.1016/0141-5425(93)90065-7 ↗
23. Numerical Optimization of Hip-Prosthetic Stem Material
24. Improved design of cementless hip stems using two-dimensional functionally graded materials10.1002/jbm.b.30509 ↗
25. Collagen-based biomaterials for tissue engineering applications10.3390/ma3031863 ↗
26. Titanium and its alloys
27. Hydroxylapatite nanoparticles: Fabrication methods and medical applications
28. Shear properties of bilaminar polymethylmethcrylate cement mantles in revision hip joint arthroplasty10.1016/j.arth.2006.04.010 ↗
29. Inhibition of staphylococcus epidermidis biofilms using polymerizable vancomycin10.1007/s11999-010-1266-z ↗
30. Stress and strain distribution within the intact femur: Compression or bending?10.1016/1350-4533(95)00031-3 ↗
31. Relation between subject specific hip joint loading10.1016/j.jbiomech.2008.09.011 ↗