journal article·2025-07-28

Effect of space holder agent on microstructural and mechanical properties of commercially pure titanium

Eyyup Murat Karakurt

Materials Testing· Volume 67· Issue 7
Publisher page

Abstract

Abstract This study aims to produce pure titanium with differing porosity levels for use as a load-bearing implant material that can mimic natural bone structure. Ti + x space holder agent (x: 0, 5, 15, and 20 wt.%) samples were prepared via powder metallurgy route, employing a pressure of 300 MPa followed by sintering at 1200 °C for 6 h. Effect of the space holder agent on the pore characteristics, phase constituent, and mechanical performance, including elastic modulus and ultimate compressive strength, were investigated. Microstructural characterizations were conducted, employing an optical microscope, scanning electron microscopy and energy dispersive spectroscopy. The phase structure was characterized by X-ray diffraction. Additionally, the mechanical behaviour of the samples achieved was assessed by uniaxial compression test at room temperature. The results from the current studies revealed that adding space holder agent effectively modified the porosity level and pore characteristics without altering the phase constituent of the samples. As the space holder agent content was increased from 0 to 20 (wt.%), the porosity level of the samples increased from 18 % to 56 %, while the ultimate compressive strength values reduced significantly from 1,236 MPa to 112 MPa.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Advanced materials and composites · Additive Manufacturing Materials and Processes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering , Osmaniye Korkut Ata Universitesi , Osmaniye , Türkiye

References (44)

Show source-provided references
1. Ş. Kasman, S. Ozan, and C. Wen, “Influence of pulse duration and frequency of laser surface texturing on the surface roughness and microstructure of CoCr28Mo alloy for biomedical applications,” Mater. Test., vol. 67, no. 1, pp. 36–48, 2025, https://doi.org/10.1515/mt-2024-0139.10.1515/mt-2024-0139 ↗
2. A. B. Karakullukcu, E. Taban, and O. O. Ojo, “Biocompatibility of biomaterials and test methods: a review,” Mater. Test., vol. 65, no. 4, pp. 545–559, 2023, https://doi.org/10.1515/mt-2022-0195.10.1515/mt-2022-0195 ↗
3. D. Yang, et al.., “Influences of sintering temperature on pore morphology, porosity, and mechanical behavior of porous Ti,” Mater. Res. Express, vol. 8, no. 10, p. 106519, 2021, https://doi.org/10.1088/2053-1591/ac1b63.10.1088/2053-1591/ac1b63 ↗
4. E. M. Karakurt, H. Yan, M. Kaya, H. Demirtaş, and Ö. Çakmak, “Effect of Zr concentration on the microstructure and mechanical performance of porous Ti-Zr system by powder metallurgy,” Key Eng. Mater., vol. 936, pp. 25–31, 2022, https://doi.org/10.4028/p-db512a.10.4028/p-db512a ↗
5. H. J. Rack and J. I. Qazi, “Titanium alloys for biomedical applications,” Mater. Sci. Eng. C, vol. 26, no. 8, pp. 1269–1277, 2006, https://doi.org/10.1016/j.msec.2005.08.032.10.1016/j.msec.2005.08.032 ↗
6. M. Kaur and K. Singh, “Review on titanium and titanium-based alloys as biomaterials for orthopaedic applications,” Mater. Sci. Eng. C, vol. 102, pp. 844–862, 2019, https://doi.org/10.1016/j.msec.2019.04.064.10.1016/j.msec.2019.04.064 ↗
7. M. Yahyazameh, M. Kavanlouei, M. Shahbaz, and Y. Beygi-Khosrowshahi, “Effect of Zr content on the microstructure, mechanical properties, electrochemical behavior, and biocompatibility of Mg–3Zn–xZr alloy using powder metallurgy,” Mater. Test., vol. 66, no. 10, pp. 1678–1692, 2024, https://doi.org/10.1515/mt-2024-0114.10.1515/mt-2024-0114 ↗
8. S. Oezcelik and A. Haeger, “A short review of modification techniques for titanium dental implant surfaces,” Curr. Dir. Biomed. Eng., vol. 10, no. 4, pp. 490–493, 2024, https://doi.org/10.1515/cdbme-2024-2120.10.1515/cdbme-2024-2120 ↗
9. J. M. Cordeiro and V. A. Barão, “Is there scientific evidence favoring the substitution of commercially pure titanium with titanium alloys for the manufacture of dental implants?” Mater. Sci. Eng. C, vol. 71, pp. 1201–1215, 2017, https://doi.org/10.1016/j.msec.2016.10.025.10.1016/j.msec.2016.10.025 ↗
10. M. McCracken, “Dental implant materials: commercially pure titanium and titanium alloys,” J. Prosthodont., vol. 8, no. 1, pp. 40–43, 1999, https://doi.org/10.1111/j.1532-849X.1999.tb00006.x.10.1111/j.1532-849X.1999.tb00006.x ↗
11. L. C. Zhang, L. Y. Chen, and L. Wang, “Surface modification of titanium and titanium alloys: technologies, developments, and future interests,” Adv. Eng. Mater., vol. 22, no. 5, p. 1901258, 2020, https://doi.org/10.1002/adem.201901258.10.1002/adem.202070017 ↗
12. E. M. Karakurt, et al.., “Assessing microstructural, biomechanical, and biocompatible properties of TiNb alloys for potential use as load-bearing implants,” J. Funct. Biomater., vol. 15, no. 9, p. 253, 2024, https://doi.org/10.3390/jfb15090253.10.3390/jfb15090253 ↗
13. A. Roegnitz and A. Haeger, “The tribological behaviour of titanium alloys suitable for dental implants: a short review,” Curr. Dir. Biomed. Eng., vol. 10, no. 4, pp. 530–534, 2024, https://doi.org/10.1515/cdbme-2024-2130.10.1515/cdbme-2024-2130 ↗
14. F. A. Shah, M. Trobos, P. Thomsen, and A. Palmquist, “Commercially pure titanium (cp-Ti) versus titanium alloy (Ti6Al4V) materials as bone anchored implants – is one truly better than the other?” J. Mater. Sci. Eng. C, vol. 62, pp. 960–966, 2016, https://doi.org/10.1016/j.msec.2016.01.032.10.1016/j.msec.2016.01.032 ↗
15. A. Chmielewska and D. Dean, “The role of stiffness-matching in avoiding stress shielding-induced bone loss and stress concentration-induced skeletal reconstruction device failure,” Acta Biomater., vol. 173, pp. 51–65, 2024, https://doi.org/10.1016/j.actbio.2023.11.011.10.1016/j.actbio.2023.11.011 ↗
16. H. S. Hedia, S. M. Aldousari, H. A. Timraz, and N. Fouda, “Stress shielding reduction via graded porosity of a femoral stem implant,” Mater. Test., vol. 61, no. 7, pp. 695–704, 2019, https://doi.org/10.3139/120.111374.10.3139/120.111374 ↗
17. F. Zhang, J. Dong, X. Luo, and B. Liu, “Mechanical behavior of shape memory alloys considering the effects of body fluids corrosion for biomedical applications,” Mater. Test., vol. 66, no. 12, pp. 1972–1979, 2024, https://doi.org/10.1515/mt-2024-0012.10.1515/mt-2024-0012 ↗
18. E. M. Karakurt, et al.., “Microstructural, biomechanical, and in vitro studies of Ti-Nb-Zr alloys fabricated by powder metallurgy,” Mater, vol. 16, no. 12, p. 4240, 2023, https://doi.org/10.3390/ma16124240.10.3390/ma16124240 ↗
19. A. Nouri, A. R. Shirvan, Y. Li, and C. Wen, “Additive manufacturing of metallic and polymeric load-bearing biomaterials using laser powder bed fusion: a review,” J. Mater. Sci. Technol., vol. 94, pp. 196–215, 2021, https://doi.org/10.1016/j.jmst.2021.03.058.10.1016/j.jmst.2021.03.058 ↗
20. M. Rana, S. K. Karmakar, B. Pal, P. Datta, A. Roychowdhury, and A. Bandyopadhyay, “Design and manufacturing of biomimetic porous metal implants,” J. Mater. Res., vol. 36, pp. 3952–3962, 2021, https://doi.org/10.1557/s43578-021-00307-1.10.1557/s43578-021-00307-1 ↗
21. K. Pałka and R. Pokrowiecki, “Porous titanium implants: a review,” Adv. Eng. Mater., vol. 20, no. 5, p. 1700648, 2018, https://doi.org/10.1002/adem.201700648.10.1002/adem.201700648 ↗
22. H. Jodati, B. Yılmaz, and Z. Evis, “A review of bioceramic porous scaffolds for hard tissue applications: effects of structural features,” Ceram. Int., vol. 46, no. 10, pp. 15725–15739, 2020, https://doi.org/10.1016/j.ceramint.2020.03.192.10.1016/j.ceramint.2020.03.192 ↗
23. Ö. Çakmak and M. Kaya, “Effect of sintering procedure on microstructure and mechanical properties of biomedical TiNbSn alloy produced via powder metallurgy,” Appl. Phys. A, vol. 127, no. 7, p. 561, 2021, https://doi.org/10.1007/s00339-021-04678-4.10.1007/s00339-021-04678-4 ↗
24. D. R. Sumner, “Long-term implant fixation and stress-shielding in total hip replacement,” J. Biomech., vol. 48, no. 5, pp. 797–800, 2015, https://doi.org/10.1016/j.jbiomech.2014.12.021.10.1016/j.jbiomech.2014.12.021 ↗
25. S. Arabnejad, B. Johnston, M. Tanzer, and D. Pasini, “Fully porous 3D printed titanium femoral stem to reduce stress‐shielding following total hip arthroplasty,” J. Orthop. Res., vol. 35, no. 8, pp. 1774–1783, 2017, https://doi.org/10.1002/jor.23445.10.1002/jor.23445 ↗
26. K. Rafiee, H. Naffakh-Moosavy, and E. Tamjid, “The effect of laser frequency on roughness, microstructure, cell viability and attachment of Ti6Al4V alloy,” Mater. Sci. Eng. C, vol. 109, pp. 110637, 2020, https://doi.org/10.1016/j.msec.2020.110637.10.1016/j.msec.2020.110637 ↗
27. K. Dvorak, “Implant bone screw characteristics of a printed PLA-based material,” Mater. Test., vol. 66, no. 11, pp. 1766–1775, 2024, https://doi.org/10.1515/mt-2024-0261.10.1515/mt-2024-0261 ↗
28. N. Poondla, T. S. Srivatsan, A. Patnaik, and M. Petraroli, “A study of the microstructure and hardness of two titanium alloys: commercially pure and Ti–6Al–4V,” J. Alloys Compd., vol. 486, nos. 1–2, pp. 162–167, 2009, https://doi.org/10.1016/j.jallcom.2009.06.172.10.1016/j.jallcom.2009.06.172 ↗
29. J. L. Hernandez and K. A. Woodrow, “Medical applications of porous biomaterials: features of porosity and tissue‐specific implications for biocompatibility,” Adv. Healthc. Mater., vol. 11, no. 9, p. 2102087, 2022, https://doi.org/10.1002/adhm.202102087.10.1002/adhm.202102087 ↗
30. A. Bandyopadhyay, I. Mitra, J. D. Avila, M. Upadhyayula, and S. Bose, “Porous metal implants: processing, properties, and challenges,” Int. J. Extrem. Manuf., vol. 5, no. 3, p. 032014, 2023, https://doi.org/10.1088/2631-7990/acdd35.10.1088/2631-7990/acdd35 ↗
31. N. Abbasi, S. Hamlet, R. M. Love, and N. T. Nguyen, “Porous scaffolds for bone regeneration,” J. Sci. Adv. Mater. Devices, vol. 5, no. 1, pp. 1–9, 2020, https://doi.org/10.1016/j.jsamd.2020.01.007.10.1016/j.jsamd.2020.01.007 ↗
32. N. Koju, S. Niraula, and B. Fotovvati, “Additively manufactured porous Ti6Al4V for bone implants: a review,” Metals, vol. 12, no. 4, p. 687, 2022, https://doi.org/10.3390/met12040687.10.3390/met12040687 ↗
33. B. Y. Li, L. J. Rong, Y. Y. Li, and V. E. Gjunter, “Synthesis of porous Ni–Ti shape-memory alloys by self-propagating high-temperature synthesis: reaction mechanism and anisotropy in pore structure,” Acta Biomater., vol. 48, pp. 3895–3904, 2000, https://doi.org/10.1016/S1359-6454(00)00184-1.10.1016/S1359-6454(00)00184-1 ↗
34. J. L. Xu, S. C. Tao, L. Z. Bao, J. M. Luo, and Y. F. Zheng, “Effects of Mo contents on the microstructure, properties and cytocompatibility of the microwave sintered porous Ti-Mo alloys,” Mater. Sci. Eng. C, vol. 97, pp. 156–165, 2019, https://doi.org/10.1016/j.msec.2018.12.028.10.1016/j.msec.2018.12.028 ↗
35. Y. Chen, et al.., “Mechanical properties and biocompatibility of porous titanium scaffolds for bone tissue engineering,” J. Mech. Behav. Biomed. Mater., vol. 75, pp. 169–174, 2017, https://doi.org/10.1016/j.jmbbm.2017.07.015.10.1016/j.jmbbm.2017.07.015 ↗
36. A. Civantos, et al.., “In vitro bone cell behavior on porous titanium samples: influence of porosity by loose sintering and space holder techniques,” Metals, vol. 10, no. 5, p. 696, 2020, https://doi.org/10.3390/met10050696.10.3390/met10050696 ↗
37. A. Bandyopadhyay, I. Mitra, S. B. Goodman, M. Kumar, and S. Bose, “Improving biocompatibility for next generation of metallic implants,” Prog. Mater. Sci., vol. 133, p. 101053, 2023, https://doi.org/10.1016/j.pmatsci.2022.101053.10.1016/j.pmatsci.2022.101053 ↗
38. H. Zhang, W. Wang, L. Yuan, Z. Wei, and W. Zhang, “Quantitative phase analysis of Ti-3Al-5Mo-4.5 V dual phase titanium alloy by XRD whole pattern fitting method,” Mater. Charact., vol. 187, pp. 111854, 2022, https://doi.org/10.1016/j.matchar.2022.111854.10.1016/j.matchar.2022.111854 ↗
39. B. Q. Li, F. Yan, and X. Lu, “Effect of microstructure on the tensile property of porous Ti produced by powder metallurgy technique,” Mater. Sci. Eng. A, vol. 534, pp. 43–52, 2012, https://doi.org/10.1016/j.msea.2011.11.028.10.1016/j.msea.2011.11.028 ↗
40. S. Lascano, et al.., “Porous titanium for biomedical applications: evaluation of the conventional powder metallurgy frontier and space-holder technique,” Appl. Sci., vol. 9, no. 5, p. 982, 2019, https://doi.org/10.3390/app9050982.10.3390/app9050982 ↗
41. N. Tuncer, G. Arslan, E. Maire, and L. Salvo, “Investigation of spacer size effect on architecture and mechanical properties of porous titanium,” Mater. Sci. Eng. A, vol. 530, pp. 633–642, 2011, https://doi.org/10.1016/j.msea.2011.10.036.10.1016/j.msea.2011.10.036 ↗
42. H. S. Hedia and I. M. Najjar, “Bio-medical materials in human joint implants—a review,” Mater. Test., vol. 53, no. 5, pp. 266–279, 2011, https://doi.org/10.3139/120.110223.10.3139/120.110223 ↗
43. E. M. Karakurt, Y. Huang, M. Kaya, H. Demirtas, A. Acikgoz, and G. Demircan, “Effect of relative density on microstructure, corrosion resistance and mechanical performance of porous Ti–20Zr alloys fabricated by powder metallurgy,” Arab. J. Sci. Eng., vol. 49, no. 2, pp. 1479–1489, 2024, https://doi.org/10.1007/s13369-023-07889-4.10.1007/s13369-023-07889-4 ↗
44. C. Torres-Sanchez, J. McLaughlin, and A. Fotticchia, “Porosity and pore size effect on the properties of sintered Ti35Nb4Sn alloy scaffolds and their suitability for tissue engineering applications,” J. Alloys Compd., vol. 731, pp. 189–199, 2018, https://doi.org/10.1016/j.jallcom.2017.10.026.10.1016/j.jallcom.2017.10.026 ↗