journal article·2025-05-26

Water as blowing agent in polyurethane resins creating porous cancellous bone surrogates for biomechanical osteosynthesis applications

Marianne Hollensteiner, Sascha Senck, Sarah Heupl, Peter Augat

Materials Testing· Volume 67· Issue 5
Publisher page

Abstract

Abstract This study examines the role of water as a blowing agent in generating porous polyurethane foams used as synthetic cancellous bone surrogates in biomechanical osteosynthesis testing. Polyurethane foams, typically used to replicate bone structures, often fail to fully mimic the intricate morphology and mechanical properties of natural bone, especially in open-cell, cancellous structures. By varying water content, with and without a cell-stabilizing agent, foams with distinct morphological and mechanical characteristics were produced. Morphometric analysis and mechanical compression testing were conducted on foams with water content ranging from 0.25 to 3 wt.%. Results indicate that decreasing water content yields denser, mechanically stiffer foams, whereas the stabilizer consistently enhanced cellular stability and uniformity. Quantitative analysis, including bone volume to total volume ratio, trabecular thickness, and connectivity density, demonstrated that specific water-stabilizer combinations align more closely with human trabecular bone. These findings suggest that optimized water-based foaming in polyurethane can improve synthetic bone models’ biomechanical fidelity, offering valuable implications for testing orthopedic implants.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone health and osteoporosis research · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

64365 BG Unfallklinik Murnau, Institute for Biomechanics , Murnau , 82418 , Germany

Research Group Computed Tomography, University of Applied Sciences Upper Austria , Stelzhamerstrasse 23 , Wels , 4600 , Oberösterreich , Austria

64365 Institute for Biomechanics , BG Unfallklinik Murnau , Murnau , Germany

References (37)

Show source-provided references
1. M. J. Gardner, M. J. Silva, and J. C. Krieg, “Biomechanical testing of fracture fixation constructs: variability, validity, and clinical applicability,” J. Am. Acad. Orthop. Surg., vol. 20, no. 2, pp. 86–93, 2012, https://doi.org/10.5435/JAAOS-20-02-086.10.5435/00124635-201202000-00004 ↗
2. S. A. Olson, J. L. Marsh, D. D. Anderson, and L. L. Latta Pe, “Designing a biomechanics investigation: choosing the right model,” J. Orthop. Trauma, vol. 26, no. 12, pp. 672–677, 2012, https://doi.org/10.1097/BOT.0b013e3182724605.10.1097/BOT.0b013e3182724605 ↗
3. J. T. Hausmann, “Sawbones in biomechanical settings - a review,” Osteosynthes. Trauma Care, vol. 14, no. 04, pp. 259–264, 2006, https://doi.org/10.1055/s-2006-942333.10.1055/s-2006-942333 ↗
4. ASTM F1839-08(2021), Standard Specification for Rigid Polyurethane Foam for Use as a Standard Material for Testing Orthopaedic Devices and Instruments, West Conshohocken, PA, ASTM International, 2021. Available at: https://www.astm.org.
5. R. Zdero, P. Brzozowski, and E. H. Schemitsch, “Biomechanical properties of artificial bones made by Sawbones: a review,” Med. Eng. Phys., vol. 118, 2023, Art. no. 104017, https://doi.org/10.1016/j.medengphy.2023.104017.10.1016/j.medengphy.2023.104017 ↗
6. R. Zdero, A. Djuricic, and E. Schemitsch, “Mechanical properties of synthetic bones made by synbone: a review,” J. Biomech. Eng., vol. 145, 2023, Art. no. 104017, https://doi.org/10.1115/1.4063123.10.1115/1.4063123 ↗
7. K. L. Calvert, K. P. Trumble, T. J. Webster, and L. A. Kirkpatrick, “Characterization of commercial rigid polyurethane foams used as bone analogs for implant testing,” J. Mater. Sci. Mater. Med., vol. 21, no. 5, pp. 1453–1461, 2010, https://doi.org/10.1007/s10856-010-4024-6.10.1007/s10856-010-4024-6 ↗
8. S. Gomez, M. D. Vlad, J. Lopez, M. Navarro, and E. Fernandez, “Characterization and three-dimensional reconstruction of synthetic bone model foams,” Mater. Sci. Eng. C Mater. Biol. Appl., vol. 33, no. 6, pp. 3329–3335, 2013, https://doi.org/10.1016/j.msec.2013.04.013.10.1016/j.msec.2013.04.013 ↗
9. H. Simpson and P. Augat, Experimental Research Methods in Orthopedics and Trauma, Stuttgart, Georg Thieme Verlag, 2015.10.1055/b-0035-122000 ↗
10. E. F. Morgan, G. U. Unnikrisnan, and A. I. Hussein, “Bone mechanical properties in healthy and diseased states,” Annu. Rev. Biomed. Eng., vol. 20, pp. 119–143, 2018, https://doi.org/10.1146/annurev-bioeng-062117-121139.10.1146/annurev-bioeng-062117-121139 ↗
11. N. Gama, R. Silva, M. Costa, A. Barros-Timmons, and A. Ferreira, “Statistical evaluation of the effect of formulation on the properties of crude glycerol polyurethane foams,” Polymer Testing, vol. 56, pp. 200–206, 2016, https://doi.org/10.1016/j.polymertesting.2016.10.006.10.1016/j.polymertesting.2016.10.006 ↗
12. E. Zharinova, M. Heuchel, T. Weigel, D. Gerber, K. Kratz, and A. Lendlein, “Water-blown polyurethane foams showing a reversible shape-memory effect,” Polymers (Basel), vol. 8, no. 12, 2016, https://doi.org/10.3390/polym8120412.10.3390/polym8120412 ↗
13. S. Klinger, M. Greinwald, P. Augat, and M. Hollensteiner, “Mechanical and morphometric characterization of custom-made trabecular bone surrogates,” J. Mech. Behav. Biomed. Mater., vol. 129, 2022, Art. no. 105146, https://doi.org/10.1016/j.jmbbm.2022.105146.10.1016/j.jmbbm.2022.105146 ↗
14. T. M. Keaveny, T. P. Pinilla, R. P. Crawford, D. L. Kopperdahl, and A. Lou, “Systematic and random errors in compression testing of trabecular bone,” J. Orthop. Res., vol. 15, no. 1, pp. 101–110, 1997, https://doi.org/10.1002/jor.1100150115.10.1002/jor.1100150115 ↗
15. D. Fürst, S. Senck, M. Hollensteiner, et al.., “Characterization of synthetic foam structures used to manufacture artificial vertebral trabecular bone,” Mater. Sci. Eng. C Mater. Biol. Appl., vol. 76, pp. 1103–1111, 2017, https://doi.org/10.1016/j.msec.2017.03.158.10.1016/j.msec.2017.03.158 ↗
16. C. H. Turner and D. B. Burr, “Basic biomechanical measurements of bone: a tutorial,” Bone, vol. 14, no. 4, pp. 595–608, 1993, https://doi.org/10.1016/8756-3282(93)90081-k.10.1016/8756-3282(93)90081-K ↗
17. T. R. Hildebrand and P. Ruegsegger, “A new method for the model-independent assessment of thickness in three-dimensional images,” J. Microsc., vol. 185, no. 1, pp. 67–75, 2003, https://doi.org/10.1046/j.1365-2818.1997.1340694.x.10.1046/j.1365-2818.1997.1340694.x ↗
18. E. Remy and E. Thiel, “Medial axis for chamfer distances: computing look-up tables and neighbourhoods in 2D or 3D,” Pattern Recogn. Lett., vol. 23, pp. 649–661, 2002, https://doi.org/10.1016/s0167-8655(01)00141-6.10.1016/S0167-8655(01)00141-6 ↗
19. L. Brizi, M. Barbieri, F. Baruffaldi, et al.., “Bone volume-to-total volume ratio measured in trabecular bone by single-sided NMR devices,” Magn. Reson. Med., vol. 79, no. 1, pp. 501–510, 2018, https://doi.org/10.1002/mrm.26697.10.1002/mrm.26697 ↗
20. P. Augat and F. Eckstein, “Quantitative imaging of musculoskeletal tissue,” Annu. Rev. Biomed. Eng., vol. 10, pp. 369–390, 2008, https://doi.org/10.1146/annurev.bioeng.10.061807.160533.10.1146/annurev.bioeng.10.061807.160533 ↗
21. E. Klintstrom, O. Smedby, B. Klintstrom, T. B. Brismar, and R. Moreno, “Trabecular bone histomorphometric measurements and contrast-to-noise ratio in CBCT,” Dentomaxillofac. Radiol., vol. 43, no. 8, 2014, Art. no. 20140196, https://doi.org/10.1259/dmfr.20140196.10.1259/dmfr.20140196 ↗
22. P. L. Salmon, C. Ohlsson, S. J. Shefelbine, and M. Doube, “Structure model index does not measure rods and plates in trabecular bone,” Front Endocrinol. (Lausanne), vol. 6, p. 162, 2015, https://doi.org/10.3389/fendo.2015.00162.10.3389/fendo.2015.00162 ↗
23. J. H. Kinney and A. J. Ladd, “The relationship between three-dimensional connectivity and the elastic properties of trabecular bone,” J. Bone Miner. Res., vol. 13, no. 5, pp. 839–845, 1998, https://doi.org/10.1359/jbmr.1998.13.5.839.10.1359/jbmr.1998.13.5.839 ↗
24. B. Brunet-Imbault, G. Lemineur, C. Chappard, R. Harba, and C. L. Benhamou, “A new anisotropy index on trabecular bone radiographic images using the fast Fourier transform,” BMC Med. Imaging, vol. 5, no. 4, 2005, https://doi.org/10.1186/1471-2342-5-4.10.1186/1471-2342-5-4 ↗
25. K. Engelke, B. Stampa, W. Timm, et al.., “Short-term in vivo precision of BMD and parameters of trabecular architecture at the distal forearm and tibia,” Osteoporos Int., vol. 23, no. 8, pp. 2151–2158, 2012, https://doi.org/10.1007/s00198-011-1829-1.10.1007/s00198-011-1829-1 ↗
26. I. H. Parkinson and N. L. Fazzalari, “Interrelationships between structural parameters of cancellous bone reveal accelerated structural change at low bone volume,” J. Bone Miner. Res., vol. 18, no. 12, pp. 2200–2205, 2003, https://doi.org/10.1359/jbmr.2003.18.12.2200.10.1359/jbmr.2003.18.12.2200 ↗
27. Z. J. Tsegai, M. M. Skinner, D. H. Pahr, J. J. Hublin, and T. L. Kivell, “Systemic patterns of trabecular bone across the human and chimpanzee skeleton,” J. Anat., vol. 232, no. 4, pp. 641–656, 2018, https://doi.org/10.1111/joa.12776.10.1111/joa.12776 ↗
28. S. Sukhdeo, J. Parsons, X. M. Niu, and T. M. Ryan, “Trabecular bone structure in the distal femur of humans, apes, and baboons,” Anat. Rec. (Hoboken), vol. 303, no. 1, pp. 129–149, 2020, https://doi.org/10.1002/ar.24050.10.1002/ar.24050 ↗
29. A. Tabassum, M. K. Chainchel Singh, N. Ibrahim, S. Ramanarayanan, and M. Y. P. Mohd Yusof, “Quantifications of mandibular trabecular bone microstructure using cone beam computed tomography for age estimation: a preliminary study,” Biology (Basel), vol. 11, no. 10, p. 1521, 2022, https://doi.org/10.3390/biology11101521.10.3390/biology11101521 ↗
30. R. Oftadeh, M. Perez-Viloria, J. C. Villa-Camacho, A. Vaziri, and A. Nazarian, “Biomechanics and mechanobiology of trabecular bone: a review,” J. Biomech. Eng., vol. 137, no. 1, pp. 0108021–01080215, 2015, https://doi.org/10.1115/1.4029176.10.1115/1.4029176 ↗
31. C. M. Yakacki, M. Poukalova, R. E. Guldberg, et al.., “The effect of the trabecular microstructure on the pullout strength of suture anchors,” J. Biomech., vol. 43, no. 10, pp. 1953–1959, 2010, https://doi.org/10.1016/j.jbiomech.2010.03.013.10.1016/j.jbiomech.2010.03.013 ↗
32. J. T. Ho, J. Wu, H. L. Huang, M. Y. Chen, L. J. Fuh, and J. T. Hsu, “Trabecular bone structural parameters evaluated using dental cone-beam computed tomography: cellular synthetic bones,” Biomed. Eng. Online, vol. 12, p. 115, 2013, https://doi.org/10.1186/1475-925X-12-115.10.1186/1475-925X-12-115 ↗
33. C. Greenwood, J. Clement, A. Dicken, et al.., “The micro-architecture of human cancellous bone from fracture neck of femur patients in relation to the structural integrity and fracture toughness of the tissue,” Bone Rep., vol. 3, pp. 67–75, 2015, https://doi.org/10.1016/j.bonr.2015.10.001.10.1016/j.bonr.2015.10.001 ↗
34. H. Hasegawa, N. Nango, and M. Machida, “Evaluation of trabecular microstructure of cancellous bone using quarter-detector computed tomography,” Diagnostics (Basel), vol. 13, no. 7, 2023, https://doi.org/10.3390/diagnostics13071240.10.3390/diagnostics13071240 ↗
35. C. Oefner, E. Riemer, K. Funke, M. Werner, C. E. Heyde, and S. Schoenfelder, “Determination of anisotropic elastic parameters from morphological parameters of cancellous bone for osteoporotic lumbar spine,” Med. Biol. Eng. Comput., vol. 60, no. 1, pp. 263–278, 2022, https://doi.org/10.1007/s11517-021-02465-0.10.1007/s11517-021-02465-0 ↗
36. P. S. Patel, D. E. T. Shepherd, and D. W. L. Hukins, “Compressive properties of commercially available polyurethane foams as mechanical models for osteoporotic human cancellous bone,” BMC Musculoskelet. Disord., vol. 9, no. 9, p. 137, 2008, https://doi.org/10.1186/1471-2474-9-137.10.1186/1471-2474-9-137 ↗
37. J. A. Szivek, M. Thmas, and J. B. Benjamin, “Characterization of a synthetic foam as a model for human cancellous bone,” J. Appl. Biomat., vol. 4, no. 3, pp. 269–272, 1993.10.1002/jab.770040309 ↗