Abstract

Cervical cancer prevention relies on vaccination, screening and treatment. While cytology and human papillomavirus (HPV) DNA testing are widely used in high-income settings, low-resource contexts commonly rely on visual inspection with acetic acid. However, high cost, subjective interpretation, and patient discomfort associated with speculum-based inspection limit uptake. This study investigates the structural behaviour of a dilation mechanism within a novel speculum-free cervical cancer screening device designed for improved accessibility and comfort. From a mechanical perspective, characterising stress, deformation, and failure is essential to optimise the material, geometry, and actuation of the cup to withstand contact and manipulation while meeting safety standards. Using finite-element analysis and iterative prototype design, we quantify stress, deformation, actuation force and collapse behaviour under simplified loading conditions to identify key geometric and material features that improve structural stability and reduce actuation effort. Iterative design enhancements introduced a staged collapse sequence, radial reinforcement rings, and optimised pull pin placement to streamline the cup’s collapsed shape and improve insertion ease while maintaining structural stability. The results demonstrated significant advancements in key performance metrics. Actuation forces were reduced to below 6 N to ensure usability, while the collapsing factor was increased, resulting in a more compact insertion profile. Radial strength was optimised through reinforcement rings and geometric adjustments, enabling the dilation cup to resist deformation at higher pressures without compromising its collapse functionality. Experimental validation demonstrated the effectiveness of incremental design modifications, such as tuning pull-pin angles and reinforcement placement, in balancing structural rigidity. Despite limitations such as boundary condition assumptions and lack of cadaveric studies, the study provides an engineering basis for subsequent bench, tissue-phantom and clinical validation.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Cervical Cancer and HPV Research · Endometrial and Cervical Cancer Treatments · Cervical and Thoracic Myelopathy

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (38)

Show source-provided references
1. L. Bruni, G. Albero, B. Serrano, M. Mena, J. Collado, D. Gómez, J. Muñoz, F. Bosch, S. de Sanjosé, Human papillomavirus and related diseases in South Africa, 2023.
2. World Health Organization, Global strategy to accelerate the elimination of cervical cancer as a public health problem, 2020.
3. Cervical cancer screening uptake in Sub-Saharan Africa: a systematic review and meta-analysis10.1016/j.puhe.2021.04.014 ↗
4. Cervical cancer screening: past, present, and future10.1016/j.sxmr.2019.09.005 ↗
5. W. Prendiville, R. Sankaranarayanan, Colposcopy and treatment of cervical precancer, Lyon (FR), 2017.
6. Accuracy of visual screening for cervical neoplasia: results from an IARC multicentre study in India and Africa10.1002/ijc.20190 ↗
7. Safety of screening with Human papillomavirus testing for cervical cancer at three-year intervals in a high-risk population: experience from the LAMS study10.1258/jms.2008.007061 ↗
8. Smartphone-based visual inspection with acetic acid: an innovative tool to improve cervical cancer screening in low-resource setting10.3390/healthcare10020391 ↗
9. Properties and safety of cervical dilators10.1016/0002-9378(83)90997-3 ↗
10. A review of the mechanism of action and clinical applications of osmotic dilators for cervical ripening in the induction of labor and in gynecology procedures10.12659/MSM.940127 ↗
11. Material Impact on Performance of Suction Cups: A Finite Element Analysis
12. Digital stretching of cervix in the active phase of labour to shorten its duration: a randomised control trial10.1177/0049475517703279 ↗
13. Finite element analysis of biomechanical interactions of a subcutaneous suspension suture and human face soft-tissue: a cadaver study10.1186/s12938-023-01144-5 ↗
14. In vivo and in vitro study of resorbable magnesium wires for medical implants: Mg purity, surface quality, Zn alloying and polymer coating10.1016/j.jma.2024.06.003 ↗
15. K. Baylous, R. Helbock, B. Kovarovic, S. Anam, M. Slepian, D. Bluestein, In silico fatigue optimization of TAVR stent designs with physiological motion in a beating heart model, 2023.10.1016/j.cmpb.2023.107886 ↗
16. Visual inspection with acetic acid (via) screening program: 7 years experience in early detection of cervical cancer and pre-cancers in rural South India10.4103/0970-0218.158873 ↗
17. Comparison between menstrual cups: first step to categorization and improved safety
18. Remote actuation systems for fully wearable assistive devices: requirements, selection, and optimization for out-of-the-lab application of a hand exoskeleton10.3389/frobt.2020.596185 ↗
19. Baseline dimensions of the human vagina10.1093/humrep/del022 ↗
20. Novel instrumented probe for measuring 3D pressure distribution along the vaginal canal10.1016/j.jbiomech.2017.04.035 ↗
21. Limits to the control of the human thumb and fingers in flexion and extension10.1152/jn.00797.2009 ↗
22. Development of a multimodal mobile colposcope for real-time cervical cancer detection10.1364/BOE.463253 ↗
23. Finite element analysis and design optimization of a pneumatically actuating silicone module for robotic surgery applications10.1089/soro.2014.0016 ↗
24. Design and material characterization of an inflatable vaginal dilator
25. Omnidirectional soft pneumatic actuators: a design and optimization framework10.3389/frobt.2024.1418484 ↗
26. Finite Element Analysis of O-ring Performance Reinforced by a Metallic Core
27. Multi-objective optimization of stress concentration factors for fatigue design of internal ring-reinforced KT-joints undergoing brace axial compression10.28991/CEJ-2024-010-06-03 ↗
28. Actuation mechanism of microvalves: a review10.3390/mi11020172 ↗
29. M. Hejazi, F. Sassani, J. Gagnon, Y. Hsiang, S. Phani, Deformation mechanics of self-expanding venous stents: modelling and experiments, 2021. 〈http://arxiv.org/abs/2102.10219〉.10.1016/j.jbiomech.2021.110333 ↗
30. Actuators for implantable devices: a broad view10.3390/mi13101756 ↗
31. Safety assessment scheme for menstrual cups and application for the evaluation of a menstrual cup comprised of medical grade silicone10.1016/j.ebiom.2022.104339 ↗
32. Acetabular cup design influences deformational response in total hip arthroplasty basic research, in
33. Influence of the acetabular cup material on the shell deformation and strain distribution in the adjacent bone-a finite element analysis10.3390/ma13061372 ↗
34. Vaginal dilators: issues and answers10.1016/j.sxmr.2019.11.005 ↗
35. Design and material characterization of an inflatable vaginal dilator10.3390/ma17051050 ↗
36. A novel speculum-free imaging strategy for visualization of the internal female lower reproductive system10.1038/s41598-020-72219-9 ↗
37. Cervical imaging in the low resource setting: a review10.3390/bios12100786 ↗
38. Comparison between menstrual cups: first step to categorization and improved safety