Development of New Ti–Fe–Ta and Ti–Fe–Ta–Zr System Alloys for Biomedical Applications [Retracted]
Source abstract
Abstract
β-type titanium alloys consisting of non-toxic elements, Ti-8Fe-8Ta, Ti-8Fe-8Ta-4Zr, and Ti-10Fe-10Ta-4Zr, were newly designed and developed for biomedical applications. Changes in the mechanical properties of the designed alloys with various heat treatments were discussed on the basis of the resultant microstructures. In addition, the corrosion resistance of the designed alloys was evaluated by polarization test in Hanks' solution. Conventional biomedical titanium and a titanium alloy, cp-Ti and Ti-6Al-4V ELI, respectively, were also polarized for comparison. The structural phase of the designed alloys after cold rolling and solution treatment was only the β phase. The ultimate tensile strength and elongation to fracture of Ti-8Fe-8Ta, Ti-8Fe-8Ta-4Zr, and Ti-10Fe-10Ta-4Zr after solution treatment were 1066 MPa and 10%, 1051 MPa and 10%, and 1092 MPa and 6%, respectively. Ti-8Fe-8Ta and Ti-8Fe-8Ta-4Zr have higher strength than conventional biomedical titanium alloys, such as Ti-6Al-4V ELI, Ti-6Al-7Nb, and Ti-13Nb-13Zr. In addition, the elongations to fracture of Ti-8Fe-8Ta and Ti-8Fe-8Ta-4Zr were equal to those of Ti-6Al-4V ELI and Ti-6Al-7Nb. The designed alloys and conventional biomedical titanium alloys were spontaneously passivated in Hanks' solution. The current density of cp-Ti and Ti-6Al-4V ELI was increased at a potential above 2.5 V. On the other hand, the current density of the designed alloys was abruptly increased at a potential above 3.5 V. This indicated that the designed alloys have an advantage over cp-Ti and Ti-6Al-4V ELI, namely, high resistance to pitting corrosion in biological environments. Therefore, the new β-type titanium alloys designed in this study, Ti-8Fe-8Ta and Ti-8Fe-8Ta-4Zr, are expected to have good properties as biomaterials.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Magnesium Alloys: Properties and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Biomaterials Center, National Institute for Materials Science
Japan Lifeline Co., Ltd.
Department of Metallurgy, Division of Biomaterials, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University
References (12)
Show source-provided references
1. 1) K. Wang: Mater. Sci. Eng. A213 (1996) 134–137.
2. 3) M. Semlitsch, F. Staub and H. Weber: Biomed. Technik. 30 (1985) 334–339.10.1515/bmte.1985.30.12.334 ↗
3. 6) P. Slanina, W. Frech, A. Bernhardson, A. Cedergren and P. Mattsson: Acta Pharmacol. Toxicol. 56 (1985) 331–336.10.1111/j.1600-0773.1985.tb01299.x ↗
4. 7) H. Kawahara: J. Jpn. Inst. Met. 31 (1992) 1033–1039.10.2320/materia1962.31.1033 ↗
5. 8) M. Niinomi: Mater. Sci. Eng. A243 (1998) 231–236.
6. 11) D. Kuroda, M. Niinomi, M. Morinaga, Y. Kato and T. Yashiro: Mater. Sci. Eng. A243 (1998) 244–249.10.1016/S0921-5093(97)00808-3 ↗
7. 12) Y. Song, D. S. Xu, R. Yang, D. Li, W. T. Wu and Z. X. Guo: Mater. Sci. Eng. A260 (1999) 269–274.
8. 13) M. Ikeda, K. Inoue, S. Komatsu, T. Sugimoto and K. Kamei: Tetsu-to-Hagane 84 (1998) 206–211.10.2355/tetsutohagane1955.84.3_206 ↗
9. 14) M. Ikeda, S. Komatsu, T. Sugimoto, S. Kamei and K. Inoue: Tetsu-to-Hagane 84 (1998) 790–796.10.2355/tetsutohagane1955.84.11_790 ↗
10. 17) IARC Working Group on the Evaluation of Carcinogenic Risks to Humans: IARC Monographs on the Evaluation of Carcinogenic Risks to Humans, Vol. 74, Surgical Implants and Other Foreign Bodies, (International Agency for Research on Cancer, World Health Organization, Lyon, 1999), pp. 241–242.
11. 18) E. Yano: Toxicology Today, (Kimpodo, Tokyo, 1994), pp. 119–128.
12. 19) A. Yamamoto, Y. Kohyama and T. Hanawa: J. Biomed. Mater. Res. 59 (2001) 176–183.10.1002/jbm.1231 ↗